{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,15]],"date-time":"2025-06-15T04:05:11Z","timestamp":1749960311464,"version":"3.41.0"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Despite the introduction of different surgical techniques and implants, osteoporotic varus displaced fractures of the proximal humerus treated with an angular stable plate have still a high risk of recurrence and\/or screw penetration leading to revision surgery. Here, we describe a technique where we use an alternative approach to stabilize the humeral head by the use of apical subchondral bone anchors tightened to an angular stable plate. This technique eliminated the need for screws in the upper part of the humeral head, allowing the upper angular stable screws to be redirected to the inferomedial part of the humeral head. We named this technique the humeral head push\u2013pull plate technique or H2P3 in its abbreviated form. The technique is presented in combination with a case series.<\/jats:p>","DOI":"10.1097\/bot.0000000000002604","type":"journal-article","created":{"date-parts":[[2023,3,23]],"date-time":"2023-03-23T19:01:59Z","timestamp":1679598119000},"page":"e478-e483","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["The Humeral Head Push\u2013Pull Plate Technique: An Alternative Way to Stabilize the Humeral Head in Varus Angulated Proximal Humeral Fractures in the Elderly"],"prefix":"10.1097","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4353-8279","authenticated-orcid":false,"given":"Guy","family":"Putzeys","sequence":"first","affiliation":[{"name":"Orthopedic and Trauma Department, AZ Groeninge Hospital, Kortrijk, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1002\/acr.21563","article-title":"Epidemiology of humerus fractures in the United States: nationwide emergency department sample, 2008","volume":"64","author":"Kim","year":"2012","journal-title":"Arthritis Care Res."},{"key":"R2-20250614","first-page":"665","article-title":"The incidence of fractures among the adult population of Germany\u2013an analysis from 2009 through 2019","volume":"118","author":"Rupp","year":"2021","journal-title":"Dtsch Aerzteblatt Int."},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1177\/1758573219831506","article-title":"Comparison of surgical and non-surgical treatments for 3- and 4-part proximal humerus fractures: a network meta-analysis","volume":"12","author":"Orman","year":"2020","journal-title":"Shoulder Elb."},{"key":"R4-20250614","first-page":"CD000434","article-title":"Interventions for treating proximal humeral fractures in adults","volume":"6","author":"Handoll","year":"2022","journal-title":"Cochrane Database Syst Rev."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"1526","DOI":"10.1016\/j.jse.2018.03.009","article-title":"Operative versus nonoperative treatment of proximal humeral fractures: a systematic review, meta-analysis, and comparison of observational studies and randomized controlled trials","volume":"27","author":"Beks","year":"2018","journal-title":"J Shoulder Elb Surg."},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"e75464","DOI":"10.1371\/journal.pone.0075464","article-title":"Internal fixation versus nonoperative treatment for displaced 3-Part or 4-Part proximal humeral fractures in elderly patients: a meta-analysis of randomized controlled trials","volume":"8","author":"Li","year":"2013","journal-title":"PLoS One"},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1186\/s40064-015-1522-5","article-title":"Operative versus non-operative treatment in complex proximal humeral fractures: a meta-analysis of randomized controlled trials","volume":"4","author":"Xie","year":"2015","journal-title":"Springerplus"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"e1002855","DOI":"10.1371\/journal.pmed.1002855","article-title":"Operative versus non-operative treatment for 2-part proximal humerus fracture: a multicenter randomized controlled trial","volume":"16","author":"Launonen","year":"2019","journal-title":"PLoS Med."},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.jse.2009.02.004","article-title":"The impacted varus (A2.2) proximal humeral fracture in elderly patients: is minimal fixation justified? a case control study","volume":"18","author":"Blonna","year":"2009","journal-title":"J Shoulder Elb Surg."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s13018-018-1052-2","article-title":"Geographic variation in the treatment of proximal humerus fracture: an update on surgery rates and treatment consensus","volume":"14","author":"Floyd","year":"2019","journal-title":"J Orthop Surg Res."},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/01.blo.0000194678.87258.6e","article-title":"Fixation of proximal humerus fractures using the PHILOS plate: early experience","volume":"442","author":"Koukakis","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.jse.2009.09.005","article-title":"Pitfalls and complications with locking plate for proximal humerus fracture","volume":"19","author":"Clavert","year":"2010","journal-title":"J Shoulder Elb Surg."},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BOT.0000000000000252","article-title":"Factors that influence reduction loss in proximal humerus fracture surgery","volume":"29","author":"Jung","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1016\/j.jse.2017.02.026","article-title":"How bone quality may influence intraoperative and early postoperative problems after angular stable open reduction\u2013internal fixation of proximal humeral fractures","volume":"26","author":"Spross","year":"2017","journal-title":"J Shoulder Elb Surg."},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1016\/j.jse.2019.11.026","article-title":"Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate","volume":"29","author":"Barlow","year":"2020","journal-title":"J Shoulder Elb Surg."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1097\/BOT.0b013e31819344bf","article-title":"Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome","volume":"23","author":"Solberg","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R17-20250614","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.injury.2016.01.021","article-title":"Initial varus displacement of proximal humerus fractures results in similar function but higher complication rates","volume":"47","author":"Capriccioso","year":"2016","journal-title":"Injury"},{"key":"R18-20250614","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.injury.2011.04.003","article-title":"Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus","volume":"43","author":"Hardeman","year":"2012","journal-title":"Injury"},{"key":"R19-20250614","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1097\/BOT.0000000000000051","article-title":"No contribution of tension-reducing rotator cuff sutures on locking plate fixation in a 2-Part Proximal humerus fracture model","volume":"28","author":"Sinatra","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R20-20250614","doi-asserted-by":"crossref","first-page":"e262","DOI":"10.1097\/BOT.0000000000000575","article-title":"Biomechanical contribution of tension-reducing rotator cuff sutures in 3-part proximal humerus fractures","volume":"30","author":"Arvesen","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R21-20250614","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1097\/BOT.0000000000001679","article-title":"Comparison of locked plating of varus displaced proximal humeral fractures with and without fibula allograft augmentation","volume":"34","author":"Davids","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1097\/BOT.0b013e318206eb46","article-title":"Are polyaxially locked screws advantageous in the plate osteosynthesis of proximal humeral fractures in the elderly? A prospective randomized clinical observational study","volume":"25","author":"Voigt","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1007\/s00402-019-03142-6","article-title":"Cement augmentation of the proximal humerus internal locking system in elderly patients: a multicenter randomized controlled trial","volume":"139","author":"Hengg","year":"2019","journal-title":"Arch Orthop Trauma Surg."},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.otsr.2018.04.025","article-title":"Is reverse total shoulder arthroplasty more effective than hemiarthroplasty for treating displaced proximal humerus fractures in older adults? A systematic review and meta-analysis","volume":"104","author":"Gallinet","year":"2018","journal-title":"Orthop Traumatol Surg Res."},{"key":"R25-20250614","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","article-title":"Analysis of efficacy and failure in proximal humerus fractures treated with locking plates","volume":"21","author":"Agudelo","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.jse.2016.05.016","article-title":"Coronal displacement in proximal humeral fractures: correlation between shoulder radiographic and computed tomography scan measurements","volume":"26","author":"Mele\u00e1n","year":"2017","journal-title":"J Shoulder Elb Surg."},{"key":"R27-20250614","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.injury.2019.11.030","article-title":"The influence of biplanar reduction and surgeon experience on proximal humerus fractures treated with ORIF","volume":"51","author":"Liskutin","year":"2020","journal-title":"Injury"},{"key":"R28-20250614","first-page":"319","article-title":"A clinical method for functional assessment of the shoulder","volume":"214","author":"Charalambous","year":"2014","journal-title":"Clin Orthop."},{"key":"R29-20250614","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L","article-title":"Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder, and head)","volume":"29","author":"Hudak","year":"1996","journal-title":"Am J Ind Med."},{"key":"R30-20250614","doi-asserted-by":"crossref","first-page":"e256","DOI":"10.1097\/BOT.0000000000001462","article-title":"A systematic review and standardized comparison of available evidence for outcome measures used to evaluate proximal humerus fracture patients","volume":"33","author":"Nowak","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R31-20250614","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.jse.2004.10.009","article-title":"Normalization of the constant score","volume":"14","author":"Katolik","year":"2005","journal-title":"J Shoulder Elb Surg."},{"key":"R32-20250614","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1080\/00016470410004120","article-title":"Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year","volume":"75","author":"Bj\u00f6rkenheim","year":"2004","journal-title":"Acta Orthop Scand."},{"key":"R33-20250614","doi-asserted-by":"crossref","first-page":"233","DOI":"10.2106\/JBJS.F.01351","article-title":"Displacement\/screw cutout after open reduction and locked plate fixation of humeral fractures","volume":"90","author":"Owsley","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R34-20250614","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1007\/s00068-007-7089-2","article-title":"Biology and biomechanics in osteosynthesis of proximal humerus fractures","volume":"33","author":"Hepp","year":"2007","journal-title":"Eur J Trauma Emerg Surg."},{"key":"R35-20250614","doi-asserted-by":"crossref","first-page":"S65","DOI":"10.1007\/s00198-004-1714-2","article-title":"Fractures of the proximal humerus in osteoporotic bone","volume":"16","author":"Hertel","year":"2005","journal-title":"Osteoporos Int."},{"key":"R36-20250614","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","article-title":"Predicting failure after surgical fixation of proximal humerus fractures","volume":"42","author":"Krappinger","year":"2011","journal-title":"Injury"},{"key":"R37-20250614","first-page":"1545","article-title":"Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study","volume":"69","author":"Ockert","year":"2010","journal-title":"J Trauma"},{"key":"R38-20250614","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1186\/1471-2474-14-102","article-title":"Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?","volume":"14","author":"Jung","year":"2013","journal-title":"BMC Musculoskelet Disord."},{"key":"R39-20250614","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1007\/s00264-011-1227-5","article-title":"The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study","volume":"35","author":"Zhang","year":"2011","journal-title":"Int Orthop."},{"key":"R40-20250614","first-page":"1235","article-title":"The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support","volume":"69","author":"Lescheid","year":"2010","journal-title":"J Trauma"},{"key":"R41-20250614","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.clinbiomech.2010.06.015","article-title":"Biomechanical evaluation of a new fixation technique for internal fixation of three-part proximal humerus fractures in a novel cadaveric model","volume":"25","author":"Brianza","year":"2010","journal-title":"Clin Biomech."},{"key":"R42-20250614","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13018-018-1031-7","article-title":"Inferomedial cortical bone contact and fixation with calcar screws on the dynamic and static mechanical stability of proximal humerus fractures","volume":"14","author":"Zhang","year":"2019","journal-title":"J Orthop Surg Res."},{"key":"R43-20250614","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1097\/BOT.0000000000000057","article-title":"Effect of calcar screw use in surgical neck fractures of the proximal humerus with unstable medial support: a biomechanical study","volume":"28","author":"Bai","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R44-20250614","doi-asserted-by":"crossref","first-page":"89","DOI":"10.3944\/AOTT.2010.2313","article-title":"Complications encountered in proximal humerus fractures treated with locking plate fixation","volume":"44","author":"Aksu","year":"2010","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R45-20250614","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","article-title":"A systematic review of locking plate fixation of proximal humerus fractures","volume":"42","author":"Sproul","year":"2011","journal-title":"Injury"},{"key":"R46-20250614","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/BOT.0b013e318169ef2a","article-title":"Early complications in proximal humerus fractures (OTA types 11) treated with locked plates","volume":"22","author":"Egol","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R47-20250614","doi-asserted-by":"crossref","first-page":"2176","DOI":"10.1016\/j.injury.2019.11.002","article-title":"Late screw-related complications in locking plating of proximal humerus fractures: a systematic review","volume":"50","author":"Panagiotopoulou","year":"2019","journal-title":"Injury"},{"key":"R48-20250614","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1186\/s12891-019-2907-3","article-title":"Fibular strut allograft influences reduction and outcomes after locking plate fixation of comminuted proximal humeral fractures in elderly patients: a retrospective study","volume":"20","author":"Cui","year":"2019","journal-title":"BMC Musculoskelet Disord."},{"key":"R49-20250614","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.jse.2010.12.018","article-title":"Internal fixation versus nonoperative treatment of displaced 3-part proximal humeral fractures in elderly patients: a randomized controlled trial","volume":"20","author":"Olerud","year":"2011","journal-title":"J Shoulder Elb Surg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002604","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:03:10Z","timestamp":1749924190000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002604"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":49,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002604","relation":{},"ISSN":["0890-5339"],"issn-type":[{"type":"print","value":"0890-5339"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"2023-03-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}