{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:37:52Z","timestamp":1787009872173,"version":"build-2736575974"},"reference-count":52,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The objective of this study was to compare clinical outcomes of patients with trochanteric hip fractures treated with specific different cephalomedullary nail (CMN) designs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A scoping review of the English literature was performed. Inclusion criteria were studies comparing perioperative and postoperative outcomes of trochanteric hip fractures fixated by CMNs for one of the following CMN designs: short versus long nails, blade versus screw fixation, dual versus single lag screw fixation, and application of cement augmentation. Inclusion criteria consisted of human comparative clinical trials (randomized and observational). Exclusion criteria included noncomparative studies, studies comparing CMN with non-CMN devices or with arthroplasty, studies with less than 3 months follow-up, studies that did not provide relevant clinical outcome measures, biomechanical, finite element analyses, animal, or in vitro publications. Data regarding reoperations, peri-implant fractures, mechanical failure, nonunion, infection rates, and functional outcomes were reviewed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Twenty-two studies met the inclusion criteria and formed the basis of this study. Failure of fixation rates and reoperation rates for each of the nail designs selected for evaluation is presented, in addition to specific outcome measures relevant to that nail design which was explored: peri-implant fracture\u2014short versus long nails, and specific mechanism of failure\u2014blade versus plate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Decreased failure of fixation and reoperations rates were found for integrated dual lag screw fixation. Similar fixation failure and reoperation rates were found for the long versus short nails and for blade versus screw fixation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Diagnostic, Level IV.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000002665","type":"journal-article","created":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T00:01:08Z","timestamp":1694736068000},"page":"S26-S32","source":"Crossref","is-referenced-by-count":5,"title":["Failure of Fixation in Trochanteric Hip Fractures: Does Nail Design Matter?"],"prefix":"10.1097","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6104-1135","authenticated-orcid":false,"given":"Amit","family":"Davidson","sequence":"first","affiliation":[{"name":"Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Leeds, United Kingdom; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5205-7696","authenticated-orcid":false,"given":"Peter V.","family":"Giannoudis","sequence":"additional","affiliation":[{"name":"Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Leeds, United Kingdom; and"},{"name":"NIHR Leeds Biomedical Research Center, Chapel Allerton Hospital, Leeds, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20231012","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/BF01623184","article-title":"Hip fractures in the elderly: a world-wide projection","volume":"2","author":"Cooper","year":"1992","journal-title":"Osteoporos Int"},{"key":"R2-20231012","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1302\/0301-620X.74B3.1587873","article-title":"The Gamma nail for peritrochanteric fractures","volume":"74-B","author":"Halder","year":"1992","journal-title":"J Bone Joint Surg Br"},{"key":"R3-20231012","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1302\/0301-620X.75B5.8376441","article-title":"A prospective randomised comparison of the dynamic hip screw and the gamma locking nail","volume":"75-B","author":"Radford","year":"1993","journal-title":"J Bone Joint Surg Br"},{"key":"R4-20231012","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1302\/0301-620X.74B3.1587875","article-title":"A biomechanical evaluation of the Gamma nail","volume":"74-B","author":"Rosenblum","year":"1992","journal-title":"J Bone Joint Surg Br"},{"key":"R5-20231012","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1308\/rcsann.2016.0297","article-title":"Risk factors for intramedullary nail breakage in proximal femoral fractures: a 10-year retrospective review","volume":"99","author":"Johnson","year":"2017","journal-title":"Ann R Coll Surg Engl"},{"key":"R6-20231012","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1302\/0301-620X.96B8.33644","article-title":"Predictors of failure for cephalomedullary nailing of proximal femoral fractures","volume":"96-B","author":"Kashigar","year":"2014","journal-title":"Bone Joint J"},{"key":"R7-20231012","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.injury.2022.02.002","article-title":"Stabilisation of AO OTA 31-A unstable proximal femoral fractures: does the choice of intramedullary nail affect the incidence of post-operative complications? A systematic literature review and meta-analysis","volume":"53","author":"Quartley","year":"2022","journal-title":"Injury"},{"key":"R8-20231012","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0134.R1","article-title":"Implant options for the treatment of intertrochanteric fractures of the hip","volume":"99-B","author":"Socci","year":"2017","journal-title":"Bone Joint J"},{"key":"R9-20231012","first-page":"1","article-title":"Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw","volume":"133","author":"Al-Munajjed","year":"2008","journal-title":"Stud Health Technol Inf"},{"key":"R10-20231012","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1097\/BOT.0000000000001193","article-title":"Helical blade versus screw fixation in the treatment of hip fractures with cephalomedullary devices: incidence of failure and atypical \u201cmedial cutout\u201d","volume":"32","author":"Chapman","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R11-20231012","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/BOT.0000000000000552","article-title":"Comparison of femoral head rotation and varus collapse between a single lag screw and integrated dual screw intertrochanteric hip fracture fixation device using a cadaveric hemi-pelvis biomechanical model","volume":"30","author":"Santoni","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R12-20231012","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s11751-012-0146-3","article-title":"Dual lag screw cephalomedullary nail versus the classic sliding hip screw for the stabilization of intertrochanteric fractures. A prospective randomized study","volume":"7","author":"Kouvidis","year":"2012","journal-title":"Strateg Trauma Limb Reconstr"},{"key":"R13-20231012","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1007\/s00264-013-2120-1","article-title":"A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures","volume":"37","author":"Huang","year":"2013","journal-title":"Int Orthop"},{"key":"R14-20231012","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e31819211b2","article-title":"The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression","volume":"23","author":"Ruecker","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R15-20231012","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and dislocation classification compendium\u20142018","volume":"32 Supple 1","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R16-20231012","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.3390\/jcm12041661","article-title":"Blade augmentation in nailing proximal femur fractures-An advantage despite higher costs?","volume":"12","author":"B\u00f6hringer","year":"2023","journal-title":"J Clin Med"},{"key":"R17-20231012","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.1007\/s00402-021-03752-z","article-title":"Short versus long cephalomedullary nailing of intertrochanteric fractures: a meta-analysis of 3208 patients","volume":"142","author":"Cinque","year":"2022","journal-title":"Arch Orthop Trauma Surg"},{"key":"R18-20231012","doi-asserted-by":"crossref","first-page":"Fso668","DOI":"10.2144\/fsoa-2020-0182","article-title":"Comparison of clinical and radiological outcomes in intertrochanteric fractures treated with InterTAN nail against conventional cephalomedullary nails: a systematic review","volume":"7","author":"Date","year":"2020","journal-title":"Future Sci OA"},{"key":"R19-20231012","doi-asserted-by":"crossref","first-page":"106","DOI":"10.3892\/etm.2021.11029","article-title":"Short vs. long intramedullary nail systems in trochanteric fractures: a randomized prospective single center study","volume":"23","author":"Dragosloveanu","year":"2021","journal-title":"Exp Ther Med"},{"key":"R20-20231012","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1055\/a-1291-8619","article-title":"Clinical and radiological outcomes of trochanteric AO\/OTA 31A2 fractures: comparison between helical blade and lag screw: a retrospective cohort study","volume":"160","author":"Hanc\u0131o\u011flu","year":"2022","journal-title":"Z Orthop Unfall"},{"key":"R21-20231012","doi-asserted-by":"crossref","first-page":"695","DOI":"10.52312\/jdrs.2022.789","article-title":"Comparison of helical blade versus lag screw in intertrochanteric fractures of the elderly treated with proximal femoral nail: a meta-analysis of randomized-controlled trials","volume":"33","author":"Huang","year":"2022","journal-title":"Jt Dis Relat Surg"},{"key":"R22-20231012","doi-asserted-by":"crossref","first-page":"3042","DOI":"10.1016\/j.injury.2021.01.037","article-title":"Cement augmentation of the proximal femur nail antirotation (PFNA) is associated with enhanced weight-bearing in older adults","volume":"52","author":"Keppler","year":"2021","journal-title":"Injury"},{"key":"R23-20231012","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/BOT.0000000000002045","article-title":"Does the helical blade lead to higher rates of fixation failure as compared to lag screw in the cephalomedullary nailing treatment of hip fractures? A systematic review and meta-analysis","volume":"35","author":"Kim","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R24-20231012","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/BOT.0000000000000521","article-title":"Costs and complications of short versus long cephalomedullary nailing of OTA 31-A2 proximal femur fractures in U.S. veterans","volume":"30","author":"Krigbaum","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R25-20231012","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1016\/j.injury.2022.03.001","article-title":"Periprosthetic fracture rate after short and long hip nails: analysis of a regional health database","volume":"53","author":"Larose","year":"2022","journal-title":"Injury"},{"key":"R26-20231012","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1186\/s13018-020-02031-8","article-title":"Comparison of clinical outcomes with proximal femoral nail anti-rotation versus InterTAN nail for intertrochanteric femoral fractures: a meta-analysis","volume":"15","author":"Liu","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R27-20231012","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.injury.2022.11.037","article-title":"Complications of standard versus long cephalomedullary nails in the treatment of unstable extracapsular proximal femoral fractures: a randomized controlled trial","volume":"54","author":"Mart\u00ed-Gar\u00edn","year":"2023","journal-title":"Injury"},{"key":"R28-20231012","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1007\/s00590-021-03124-8","article-title":"No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis","volume":"32","author":"Ng","year":"2021","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R29-20231012","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13018-018-0749-6","article-title":"Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures","volume":"13","author":"Nherera","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R30-20231012","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1177\/1120700020985067","article-title":"Integrated dual lag screws versus single lag screw cephalomedullary nail constructs: a meta-analysis and systematic review","volume":"32","author":"Onggo","year":"2021","journal-title":"HIP Int"},{"key":"R31-20231012","doi-asserted-by":"crossref","first-page":"2600","DOI":"10.1016\/j.injury.2022.05.036","article-title":"Quality differences in multifragmentary pertrochanteric fractures [OTA 31A2.2 and 31A2.3] treated with short and long cephalomedullary nails","volume":"53","author":"Parola","year":"2022","journal-title":"Injury"},{"key":"R32-20231012","doi-asserted-by":"crossref","first-page":"e0251894","DOI":"10.1371\/journal.pone.0251894","article-title":"Cement augmentation for trochanteric femur fractures: a meta-analysis of randomized clinical trials and observational studies","volume":"16","author":"Rompen","year":"2021","journal-title":"PLoS One"},{"key":"R33-20231012","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1007\/s00402-020-03531-2","article-title":"Cement augmentation of the proximal femur nail antirotation: is it safe?","volume":"141","author":"Schuetze","year":"2021","journal-title":"Arch Orthop Trauma Surg"},{"key":"R34-20231012","doi-asserted-by":"crossref","first-page":"304","DOI":"10.3928\/01477447-20220511-03","article-title":"Risk of peri-implant fracture with long versus short cephalomedullary nailing for geriatric patients with intertrochanteric femur fracture","volume":"45","author":"Sop","year":"2022","journal-title":"Orthopedics"},{"key":"R35-20231012","doi-asserted-by":"crossref","first-page":"23997","DOI":"10.1038\/s41598-021-03210-1","article-title":"Clinical outcomes following long versus short cephalomedullary devices for fixation of extracapsular hip fractures: a systematic review and meta-analysis","volume":"11","author":"Tan","year":"2021","journal-title":"Sci Rep"},{"key":"R36-20231012","first-page":"e21.00322","article-title":"Comparison of short, intermediate, and long cephalomedullary nail length outcomes in elderly intertrochanteric femur fractures","volume":"6","author":"Womble","year":"2022","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"R37-20231012","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1016\/j.injury.2010.09.026","article-title":"Cement augmentation of intertrochanteric fractures stabilised with intramedullary nailing","volume":"41","author":"Dall'Oca","year":"2010","journal-title":"Injury"},{"key":"R38-20231012","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1016\/j.injury.2018.04.022","article-title":"Cement augmentation of the proximal femoral nail antirotation (PFNA) - a multicentre randomized controlled trial","volume":"49","author":"Kammerlander","year":"2018","journal-title":"Injury"},{"key":"R39-20231012","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1007\/s00198-018-4572-z","article-title":"Is calcium phosphate augmentation a viable option for osteoporotic hip fractures?","volume":"29","author":"Kim","year":"2018","journal-title":"Osteoporos Int"},{"key":"R40-20231012","doi-asserted-by":"crossref","first-page":"215145932091212","DOI":"10.1177\/2151459320912121","article-title":"Predicting factors for return to prefracture ambulatory level in high surgical risk elderly patients sustained intertrochanteric fracture and treated with proximal femoral nail antirotation (PFNA) with and without cement augmentation","volume":"11","author":"Kulachote","year":"2020","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"R41-20231012","doi-asserted-by":"crossref","first-page":"1957","DOI":"10.1007\/s00402-020-03449-9","article-title":"Cementation: for better or worse? Interim results of a multi-centre cohort study using a fenestrated spiral blade cephalomedullary device for pertrochanteric fractures in the elderly","volume":"140","author":"Yee","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"key":"R42-20231012","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s00590-020-02762-8","article-title":"Trochanteric fixation nail advanced with helical blade and cement augmentation: early experience with a retrospective cohort","volume":"31","author":"Goodnough","year":"2021","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R43-20231012","doi-asserted-by":"crossref","first-page":"2768","DOI":"10.1007\/s11999-013-2948-0","article-title":"Which implant is better for treating reverse obliquity fractures of the proximal femur: a standard or long nail?","volume":"471","author":"Okcu","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"R44-20231012","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.injury.2021.11.064","article-title":"Biomechanical performance of short and long cephalomedullary nail constructs for stabilizing different levels of subtrochanteric fracture","volume":"53","author":"Chantarapanich","year":"2022","journal-title":"Injury"},{"key":"R45-20231012","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/s00402-022-04345-0","article-title":"Biomechanical stability of short versus long proximal femoral nails in osteoporotic subtrochanteric A3 reverse-oblique femoral fractures: a cadaveric study","volume":"143","author":"Linhart","year":"2022","journal-title":"Arch Orthop Trauma Surg"},{"key":"R46-20231012","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1016\/j.injury.2006.06.008","article-title":"Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation","volume":"37","author":"Strauss","year":"2006","journal-title":"Injury"},{"key":"R47-20231012","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/1749-799X-8-35","article-title":"Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study","volume":"8","author":"Nikoloski","year":"2013","journal-title":"J Orthop Surg Res"},{"key":"R48-20231012","doi-asserted-by":"crossref","first-page":"1484","DOI":"10.1016\/j.injury.2011.07.010","article-title":"Standardised cement augmentation of the PFNA using a perforated blade: a new technique and preliminary clinical results. A prospective multicentre trial","volume":"42","author":"Kammerlander","year":"2011","journal-title":"Injury"},{"key":"R49-20231012","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1016\/j.injury.2013.03.003","article-title":"Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures--a biomechanical cadaver study","volume":"44","author":"Fensky","year":"2013","journal-title":"Injury"},{"key":"R50-20231012","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.jcot.2020.10.034","article-title":"Cement augmentation for trochanteric fracture in elderly: a systematic review","volume":"15","author":"Stramazzo","year":"2021","journal-title":"J Clin Orthop Trauma"},{"key":"R51-20231012","doi-asserted-by":"crossref","first-page":"2026","DOI":"10.2106\/JBJS.21.01516","article-title":"Cost-effectiveness of cement augmentation versus no augmentation for the fixation of unstable trochanteric fractures","volume":"104","author":"Joeris","year":"2022","journal-title":"J Bone Joint Surg"},{"key":"R52-20231012","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.3390\/jpm12091392","article-title":"Effectiveness of cement augmentation on early postoperative mobility in patients treated for trochanteric fractures with cephalomedullary nailing: a prospective cohort study","volume":"12","author":"Mochizuki","year":"2022","journal-title":"J Personalized Med"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002665","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T13:01:11Z","timestamp":1697115671000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002665"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":52,"journal-issue":{"issue":"10S","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002665","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,10]]}}}