{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T10:30:49Z","timestamp":1789122649157,"version":"build-2803163510"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>The stability of intertrochanteric fractures depends upon multiple factors including the fracture displacement, location and pattern, the type of fixation used for stabilization, and the loading that the fracture undergoes postfixation. Traditional classification systems are of limited utility because they typically stratify intertrochanteric fractures as stable or unstable based purely on the fracture pattern without consideration of the stability after fixation. Biomechanical studies evaluating the stability of various fixation constructs should include physiologic loading, including rotation around the axis of the femoral neck, and reproduce clinical failure modes to be clinically relevant. A growing body of evidence indicates that the type of fixation substantially affects postoperative stability of intertrochanteric fractures.<\/jats:p>","DOI":"10.1097\/bot.0000000000002675","type":"journal-article","created":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T04:01:21Z","timestamp":1694750481000},"page":"S1-S4","source":"Crossref","is-referenced-by-count":18,"title":["Stability of Intertrochanteric Femur Fractures"],"prefix":"10.1097","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6430-3316","authenticated-orcid":false,"given":"William M.","family":"Ricci","sequence":"first","affiliation":[{"name":"Orthopaedic Trauma Service, Hospital for Special Surgery, NewYork-Presbyterian Hospital\/Weill Cornell Medical College, New York, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20231012","doi-asserted-by":"crossref","first-page":"643","DOI":"10.2106\/00004623-200105000-00001","article-title":"Reverse obliquity fractures of the intertrochanteric region of the femur","volume":"83","author":"Haidukewych","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20231012","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0134.R1","article-title":"Implant options for the treatment of intertrochanteric fractures of the hip: rationale, evidence, and recommendations","volume":"99-B","author":"Socci","year":"2017","journal-title":"Bone Joint J"},{"key":"R4-20231012","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1097\/BOT.0000000000001509","article-title":"Are two-part intertrochanteric femur fractures stable and does stability depend on fixation method?","volume":"33","author":"Ricci","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R6-20231012","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/BOT.0000000000000713","article-title":"A multicenter randomized control trial comparing a novel intramedullary device (InterTAN) versus conventional treatment (sliding hip screw) of geriatric hip fractures","volume":"31","author":"Sanders","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R7-20231012","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1097\/BOT.0b013e31828bacb4","article-title":"The effect of fracture pattern stability on implant loading in OTA type 31-A2 proximal femur fractures","volume":"27","author":"Marmor","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R8-20231012","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1186\/s13018-020-01763-x","article-title":"Effect of lesser trochanter posteromedial wall defect on the stability of femoral intertrochanteric fracture using 3D simulation","volume":"15","author":"Ren","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R9-20231012","first-page":"470","article-title":"Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation","volume":"89","author":"Palm","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"R10-20231012","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/00005131-200401000-00003","article-title":"Intramedullary fixation of unstable intertrochanteric hip fractures: one or two lag screws","volume":"18","author":"Kubiak","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R11-20231012","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BOT.0000000000000008","article-title":"Malpositioning of the lag screws by 1- or 2-screw nailing systems for pertrochanteric femoral fractures: a biomechanical comparison of gamma 3 and intertan","volume":"28","author":"N\u00fcchtern","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R12-20231012","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/j.orthres.2005.05.002.1100230614","article-title":"Lag screws for hip fracture fixation: evaluation of migration resistance under simulated walking","volume":"23","author":"Ehmke","year":"2005","journal-title":"J Orthop Res"},{"key":"R13-20231012","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/BOT.0000000000000552","article-title":"Comparison of femoral head rotation and varus collapse between a single lag screw and integrated dual screw intertrochanteric hip fracture fixation device using a cadaveric hemi-pelvis biomechanical model","volume":"30","author":"Santoni","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R14-20231012","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1002\/jor.21236","article-title":"Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method","volume":"29","author":"Born","year":"2011","journal-title":"J Orthop Res"},{"key":"R15-20231012","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1749-799X-4-16","article-title":"Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation","volume":"4","author":"Kouvidis","year":"2009","journal-title":"J Orthop Surg Res"},{"key":"R16-20231012","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/00003086-198001000-00008","article-title":"Mechanics of the treatment of hip injuries","volume":"146","author":"Kaufer","year":"1980","journal-title":"Clin Orthop Relat Res"},{"key":"R17-20231012","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.injury.2021.02.014","article-title":"Reporting on quality of reduction and fixation of intertrochanteric fractures-A systematic review","volume":"52","author":"Marmor","year":"2021","journal-title":"Injury"},{"key":"R18-20231012","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s00590-016-1746-2","article-title":"Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation","volume":"26","author":"Marmor","year":"2016","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R19-20231012","doi-asserted-by":"crossref","first-page":"4072","DOI":"10.1016\/j.injury.2022.10.006","article-title":"Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: a comparative biomechanical and finite element analysis study","volume":"53","author":"Kyriakopoulos","year":"2022","journal-title":"Injury"},{"key":"R20-20231012","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1097\/BOT.0000000000000967","article-title":"Cephalomedullary nail fixation of intertrochanteric femur fractures: are two proximal screws better than one?","volume":"31","author":"Serrano","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R21-20231012","doi-asserted-by":"crossref","first-page":"e1550","DOI":"10.5435\/JAAOS-D-22-00213","article-title":"Mechanical complications after intramedullary fixation of extracapsular hip fractures","volume":"30","author":"Klima","year":"2022","journal-title":"J Am Acad Orthop Surg"},{"key":"R22-20231012","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1097\/BOT.0000000000001283","article-title":"Gait analysis after intertrochanteric hip fracture: does shortening result in gait impairment?","volume":"32","author":"Gausden","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R23-20231012","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1016\/j.injury.2019.06.015","article-title":"Mobility after intertrochanteric hip fracture fixation with either a sliding hip screw or a cephalomedullary nail: sub group analysis of a randomised trial of 1000 patients","volume":"50","author":"Ong","year":"2019","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002675","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T17:01:41Z","timestamp":1697130101000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002675"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":21,"journal-issue":{"issue":"10S","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002675","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,10]]}}}