{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,15]],"date-time":"2025-06-15T04:05:11Z","timestamp":1749960311964,"version":"3.41.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","funder":[{"DOI":"10.13039\/100001473","name":"AO North America","doi-asserted-by":"crossref","award":["F19FELRSCH"],"award-info":[{"award-number":["F19FELRSCH"]}],"id":[{"id":"10.13039\/100001473","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>To determine change in stiffness and horizontal translation of a geriatric extra-articular proximal tibia fracture model after intramedullary nailing with distal (long)-segment blocking screws versus proximal (short)-segment blocking screws.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Unstable extra-articular proximal tibia fractures (OTA\/AO 41-A3) were created in 12 geriatric cadaveric tibias. Intramedullary nails were locked with a standard construct (4 proximal screws and 2 distal screws). Specimens were then divided into 2 groups (6 matched pairs per group). Group 1 had a blocking screw placed lateral to the nail in the proximal segment (short segment). Group 2 had a blocking screw placed 1 cm distal to the fracture and medial to the nail (long segment). Specimens were then axially loaded and cycled to failure or cycle completion (50,000 cycles).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>Long-segment blocking screws significantly decreased the amount of horizontal translation at the fracture site compared with short-segment screws (0.77 vs. 2.0 mm, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.039). They also resulted in a greater trend towards greater baseline stiffness, (807.32 \u00b1 216.95 N\/mm vs. 583.12 \u00b1 130.1 N\/mm, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.072). There was no difference in stiffness after cyclic loading or survival through 50,000 cycles between the long-segment and short-segment groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION:<\/jats:title>\n            <jats:p>Long-segment blocking screws added to an intramedullary nail construct resulted in decreased horizontal translation at the fracture site compared with short-segment screws in this model of a geriatric proximal tibia fracture.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CLINICAL RELEVANCE:<\/jats:title>\n            <jats:p>Blocking screws are commonly used to aid in fracture alignment during intramedullary nailing of proximal tibia fractures. Even when not required to attain or maintain alignment, the addition of a blocking screw in either the proximal or the distal (long) segment may help mitigate the \u201cBell-Clapper Effect\u201d in geriatric patients.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002683","type":"journal-article","created":{"date-parts":[[2023,8,10]],"date-time":"2023-08-10T04:24:19Z","timestamp":1691641459000},"page":"e4-e8","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Do Long-Segment Blocking Screws Increase the Stability of Intramedullary Nail Fixation in Proximal Tibia Fractures, Eliminating the \u201cBell-Clapper Effect?\u201d"],"prefix":"10.1097","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7271-5580","authenticated-orcid":false,"given":"Derek S.","family":"Stenquist","sequence":"first","affiliation":[{"name":"Orthopaedic Trauma Service, Tampa General Hospital\/Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meghan","family":"McCaskey","sequence":"additional","affiliation":[{"name":"Orthopaedic Trauma Service, Tampa General Hospital\/Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miguel","family":"Diaz","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education (FORE), Tampa, FL."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven D.","family":"Munassi","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education (FORE), Tampa, FL."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Ayala","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education (FORE), Tampa, FL."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Donohue","sequence":"additional","affiliation":[{"name":"Orthopaedic Trauma Service, Tampa General Hospital\/Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hassan R.","family":"Mir","sequence":"additional","affiliation":[{"name":"Orthopaedic Trauma Service, Tampa General Hospital\/Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1302\/0301-620X.77B3.7744927","article-title":"The epidemiology of tibial fractures","volume":"77-B","author":"Court-Brown","year":"1995","journal-title":"The J Bone Joint Surg Br"},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1302\/0301-620X.95B9.31112","article-title":"The outcome of tibial diaphyseal fractures in the elderly","volume":"95-B","author":"Clement","year":"2013","journal-title":"Bone Joint J"},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1097\/BOT.0b013e3181b013d2","article-title":"Intramedullary nailing versus percutaneous locked plating of extra-articular proximal tibial fractures: comparison of 56 cases","volume":"23","author":"Lindvall","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"690","DOI":"10.5435\/00124635-201111000-00005","article-title":"Intramedullary nailing of extra-articular proximal tibia fractures","volume":"19","author":"Hiesterman","year":"2011","journal-title":"Am Acad Orthop Surg"},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1097\/BOT.0000000000002451","article-title":"Immediate weight bearing as tolerated is safe following intramedullary fixation of extra-articular metaphyseal proximal tibia fractures (OTA\/AO 41-A)","volume":"37","author":"Telgheder","year":"2023","journal-title":"J Orthop Trauma"},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"e49","DOI":"10.1097\/BOT.0000000000000729","article-title":"Fatigue failure in extra-articular proximal tibia fractures: locking intramedullary nail versus double locking plates\u2014a biomechanical study","volume":"31","author":"Kandemir","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"230949902110243","DOI":"10.1177\/23094990211024395","article-title":"Comparison of intramedullary nailing fixation and percutaneous locked plating fixation for the treatment of proximal tibial fractures: a meta-analysis","volume":"29","author":"Ren","year":"2021","journal-title":"J Orthop Surg"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1302\/0301-620X.87B3.14353","article-title":"Primary stability of various forms of osteosynthesis in the treatment of fractures of the proximal tibia","volume":"87-B","author":"Mueller","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"R9-20250614","first-page":"61","article-title":"Extra-articular proximal tibial fractures: nail or plate?","volume":"62","author":"Kurylo","year":"2013","journal-title":"Instr Course Lect"},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1097\/BOT.0b013e31815aba5e","article-title":"Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN)","volume":"21","author":"Hansen","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1302\/0301-620X.81B6.0810963","article-title":"The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails","volume":"81-B","author":"Krettek","year":"1999","journal-title":"J Bone Joint Surg Br"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/00005131-199911000-00006","article-title":"The mechanical effect of blocking screws (\u201cPoller screws\u201d) in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails","volume":"13","author":"Krettek","year":"1999","journal-title":"J Orthop Trauma"},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00005131-200105000-00005","article-title":"Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws","volume":"15","author":"Ricci","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1177\/0022034510377791","article-title":"Aging and bone","volume":"89","author":"Boskey","year":"2010","journal-title":"J Dent Res"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1359\/JBMR.050326","article-title":"Relationship between bone morphology and bone quality in male tibias: implications for stress fracture risk","volume":"20","author":"Tommasini","year":"2005","journal-title":"J Bone Mineral Res"},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1097\/BOT.0000000000001284","article-title":"Long segment blocking screws increase the stability of retrograde nail fixation in geriatric supracondylar femur fractures: eliminating the \u201cBell-Clapper effect\u201d","volume":"32","author":"Auston","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R17-20250614","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1007\/s00402-008-0700-0","article-title":"Influence of intramedullary nail diameter and locking mode on the stability of tibial shaft fracture fixation","volume":"129","author":"Penzkofer","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"key":"R18-20250614","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1016\/j.injury.2010.03.003","article-title":"A biomechanical comparison of the Surgical Implant Generation Network (SIGN) tibial nail with the standard hollow nail","volume":"41","author":"Calafi","year":"2010","journal-title":"Injury"},{"key":"R19-20250614","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/BOT.0b013e3182a1f54b","article-title":"Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures","volume":"27","author":"Hoffmann","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R20-20250614","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BOT.0000000000000008","article-title":"Malpositioning of the lag screws by 1- or 2-screw nailing systems for pertrochanteric femoral fractures: a biomechanical comparison of gamma 3 and intertan","volume":"28","author":"N\u00fcchtern","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R21-20250614","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/j.injury.2009.01.117","article-title":"Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study","volume":"40","author":"Horn","year":"2009","journal-title":"Injury"},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1007\/s00068-011-0123-4","article-title":"Biomechanical comparison of two locking plate systems for the distal tibia","volume":"38","author":"H\u00f6gel","year":"2012","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/BOT.0000000000000195","article-title":"Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing","volume":"29","author":"Chan","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"312","DOI":"10.4055\/cios.2014.6.3.312","article-title":"Biomechanical analysis of operative methods in the treatment of extra-articular fracture of the proximal tibia","volume":"6","author":"Lee","year":"2014","journal-title":"Clin Orthop Surg"},{"key":"R25-20250614","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/BOT.0b013e3181e47d0f","article-title":"The biomechanics of varied proximal locking screw configurations in a synthetic model of proximal third tibial fracture fixation","volume":"25","author":"Wolinsky","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1007\/s00264-020-04821-5","article-title":"Intramedullary nailing via suprapatellar approach versus locked plating of proximal extra-articular tibial fractures: a randomized control trial","volume":"45","author":"Cheng","year":"2021","journal-title":"Int Orthop"},{"key":"R27-20250614","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s10195-014-0332-9","article-title":"Intramedullary nailing versus proximal plating in the management of closed extra-articular proximal tibial fracture: a randomized controlled trial","volume":"16","author":"Meena","year":"2015","journal-title":"J Orthop Traumatol"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002683","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:03:27Z","timestamp":1749924207000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002683"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002683","relation":{},"ISSN":["0890-5339"],"issn-type":[{"type":"print","value":"0890-5339"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"2023-08-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}