{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T22:42:46Z","timestamp":1772491366376,"version":"3.50.1"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,11]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Multidimensional fluoroscopy has been increasingly used in orthopaedic trauma to improve the intraoperative assessment of articular reductions and implant placement. Owing to the complex osteology of the pelvis, cross-sectional imaging is imperative for accurate evaluation of pelvic ring and acetabular injuries both preoperatively and intraoperatively. The continued development of fluoroscopic technology over the past decade has resulted in improved ease of intraoperative multidimensional fluoroscopy use in pelvic and acetabular surgery. This has provided orthopaedic trauma surgeons with a valuable tool to better evaluate reduction and fixation at different stages during operative treatment of these injuries. Specifically, intraoperative 3D fluoroscopy during treatment of acetabulum and pelvis injuries assists with guiding intraoperative decisions, assessing reductions, ensuring implant safety, and confirming appropriate fixation. We outline the useful aspects of this technology during pelvic and acetabular surgery and report its utility with a consecutive case series at a single institution. The added benefits of this technology have improved the ability to effectively manage patients with pelvis and acetabulum injuries.<\/jats:p>","DOI":"10.1097\/bot.0000000000002686","type":"journal-article","created":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T04:02:42Z","timestamp":1697169762000},"page":"S1-S6","source":"Crossref","is-referenced-by-count":8,"title":["Use of 3D Fluoroscopy to Assist in the Reduction and Fixation of Pelvic and Acetabular Fractures: A Safety and Quality Case Series"],"prefix":"10.1097","volume":"37","author":[{"given":"Stephen J.","family":"Warner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9477-9777","authenticated-orcid":false,"given":"Douglas R.","family":"Haase","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7460-454X","authenticated-orcid":false,"given":"Milton L.","family":"Chip Routt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9330-7540","authenticated-orcid":false,"given":"Jonathan G.","family":"Eastman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3452-0069","authenticated-orcid":false,"given":"Timothy S.","family":"Achor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20231013","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","article-title":"Early results of percutaneous iliosacral screws placed with the patient in the supine position","volume":"9","author":"Chip Routt","year":"1995","journal-title":"J Orthop Trauma"},{"key":"R2-20231013","doi-asserted-by":"crossref","first-page":"1502","DOI":"10.1097\/TA.0b013e318246efe5","article-title":"Osseous fixation pathways in pelvic and acetabular fracture surgery","volume":"72","author":"Bishop","year":"2012","journal-title":"J Trauma Acute Care Surg"},{"key":"R3-20231013","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1016\/j.injury.2022.05.035","article-title":"Fluoroscopic imaging: new advances","volume":"53","author":"Keil","year":"2022","journal-title":"Injury"},{"key":"R4-20231013","doi-asserted-by":"crossref","first-page":"e122","DOI":"10.1097\/BOT.0b013e31826046b0","article-title":"Lateral sacral imaging in the morbidly obese","volume":"27","author":"Miller","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R5-20231013","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.2106\/JBJS.K.00444","article-title":"Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures","volume":"94","author":"Tannast","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20231013","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.2106\/00004623-199611000-00002","article-title":"Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury","volume":"78","author":"Matta","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20231013","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/s00068-020-01504-z","article-title":"Anatomic reduction of the sacroiliac joint in unstable pelvic ring injuries and its correlation with functional outcome","volume":"48","author":"J\u00e4ckle","year":"2022","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R8-20231013","doi-asserted-by":"crossref","first-page":"101994","DOI":"10.1016\/j.jcot.2022.101994","article-title":"Risk factors for screw breach and iatrogenic nerve injury in percutaneous posterior pelvic ring fixation","volume":"33","author":"Hadeed","year":"2022","journal-title":"J Clin Orthop Trauma"},{"key":"R9-20231013","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1007\/s11999-008-0632-6","article-title":"Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure","volume":"467","author":"Zwingmann","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"R10-20231013","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1016\/j.injury.2013.08.008","article-title":"Intra- and postoperative complications of navigated and conventional techniques in percutaneous iliosacral screw fixation after pelvic fractures: results from the German Pelvic Trauma Registry","volume":"44","author":"Zwingmann","year":"2013","journal-title":"Injury"},{"key":"R11-20231013","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1007\/s00402-013-1788-4","article-title":"Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis","volume":"133","author":"Zwingmann","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R12-20231013","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.ocl.2020.02.010","article-title":"What's new in percutaneous pelvis fracture surgery?","volume":"51","author":"Grewal","year":"2020","journal-title":"Orthop Clin North Am"},{"key":"R13-20231013","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1016\/j.jsurg.2018.04.019","article-title":"Use of 3D printed models in resident education for the classification of acetabulum fractures","volume":"75","author":"Lim","year":"2018","journal-title":"J Surg Educ"},{"key":"R14-20231013","doi-asserted-by":"crossref","first-page":"79","DOI":"10.5435\/JAAOS-D-20-00872","article-title":"A new algorithm for classifying acetabular fracture patterns on three-dimensional computed tomography reconstructions markedly improves residents' ability to correctly classify fractures","volume":"30","author":"Shaath","year":"2022","journal-title":"J Am Acad Orthop Surg"},{"key":"R15-20231013","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.2106\/JBJS.16.01446","article-title":"Postoperative CT is superior for acetabular fracture reduction assessment and reliably predicts hip survivorship","volume":"99","author":"Verbeek","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"R16-20231013","doi-asserted-by":"crossref","first-page":"S43","DOI":"10.1097\/BOT.0000000000001405","article-title":"Does routine postoperative computerized tomography after acetabular fracture fixation affect management?","volume":"33","author":"Elnahal","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R17-20231013","doi-asserted-by":"crossref","first-page":"S66","DOI":"10.1097\/BOT.0000000000001092","article-title":"Routine postoperative computed tomography scans after pelvic fracture fixation: a necessity or a luxury?","volume":"32","author":"Elnahal","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R18-20231013","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1186\/s13018-019-1286-7","article-title":"Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases","volume":"14","author":"Beisemann","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R19-20231013","doi-asserted-by":"crossref","first-page":"110734","DOI":"10.1016\/j.injury.2023.04.021","article-title":"Implementing 3D fluoroscopy in the management of tibial plateau fractures: shorter hospitalization and decline in revision surgery, but increase in the duration of surgery and radiation exposure","volume":"54","author":"Havermans","year":"2023","journal-title":"Injury"},{"key":"R20-20231013","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.ejrad.2019.01.013","article-title":"The correlation between intra-operative 2D- and 3D fluoroscopy with postoperative CT-scans in the treatment of calcaneal fractures","volume":"112","author":"Beerekamp","year":"2019","journal-title":"Eur J Radiol"},{"key":"R21-20231013","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.nec.2017.06.002","article-title":"Intraoperative 3D computed tomography: spine surgery","volume":"28","author":"Adamczak","year":"2017","journal-title":"Neurosurg Clin North Am"},{"key":"R22-20231013","doi-asserted-by":"crossref","first-page":"S19","DOI":"10.1016\/j.otsr.2019.05.021","article-title":"Role of 3D intraoperative imaging in orthopedic and trauma surgery","volume":"106","author":"Tonetti","year":"2020","journal-title":"Orthop Traumatol Surg Res"},{"key":"R23-20231013","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1177\/1071100720926111","article-title":"Intraoperative effect of 2D vs 3D fluoroscopy on quality of reduction and patient-related outcome in calcaneal fracture surgery","volume":"41","author":"Halm","year":"2020","journal-title":"Foot Ankle Int"},{"key":"R24-20231013","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1097\/BOT.0000000000001796","article-title":"Multidimensional pelvic fluoroscopy: a new and novel technique for assessing safety and accuracy of percutaneous iliosacral screw fixation","volume":"34","author":"Shaw","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R25-20231013","doi-asserted-by":"crossref","first-page":"e20","DOI":"10.2106\/JBJS.RVW.20.00129","article-title":"Utility of 3-dimensional intraoperative imaging in pelvic and acetabular fractures","volume":"9","author":"Pisquiy","year":"2021","journal-title":"JBJS Rev"},{"key":"R26-20231013","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1007\/s00264-017-3447-9","article-title":"Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series","volume":"41","author":"Shaw","year":"2017","journal-title":"Int Orthop"},{"key":"R27-20231013","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1097\/00005131-199711000-00007","article-title":"Iliosacral screw fixation: early complications of the percutaneous technique","volume":"11","author":"Chip Routt","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R28-20231013","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1097\/BOT.0000000000000092","article-title":"Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study","volume":"28","author":"Matityahu","year":"2014","journal-title":"J Orthop Trauma"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002686","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T04:02:55Z","timestamp":1697169775000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002686"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":28,"journal-issue":{"issue":"11S","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002686","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,11]]}}}