{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T13:13:15Z","timestamp":1793884395324,"version":"4.7.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To determine (1) the natural incidence of sacral inlet angle differences between S1 and S2 and (2) implications for iliosacral screw placement with a technique to improve the accuracy of the intraoperative fluoroscopic inlet for S1 and S2.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Combined retrospective and prospective cohort reviews.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Regional Level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>After exclusion criteria, 300 patients with uninjured pelvic rings to determine the natural incidence of S1\u2013S2 angle differences and 33 patients treated with iliosacral screws over the study period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>None in the retrospective cohort. In the prospective cohort, all patients underwent fluoroscopically assisted iliosacral screw fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Radiographic determination of S1\u2013S2 angle differences above 10 degrees in a natural population for the retrospective cohort. In the prospective, operative cohort, the outcome of interest was the safety of iliosacral screws in S1 and S2 as determined on intraoperative fluoroscopy and postoperative CT scan.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In the retrospective cohort, 180 of 300 (60.0%) had S1\u2013S2 inlet angle differences above 10 degrees. In the operative cohort, 19 of 33 (57.6%) had S1\u2013S2 inlet angle differences above 10 degrees. Of the iliosacral screws in S1 and S2 placed using the described imaging technique, all (69\/69, 100%) were safe.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>A normal population determined that differences in the inlet angle between S1 and S2 are common. An operative cohort was treated using preoperative CT-based planning to define different intraoperative fluoroscopic inlet views for S1 and S2, if a larger difference existed. Using this technique, 69 of 69 (100%) iliosacral screws were safe.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002698","type":"journal-article","created":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T04:01:01Z","timestamp":1695355261000},"page":"607-613","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Iliosacral Screws Can Be Placed With Precision by Adjusting the Pelvic Inlet Between S1 and S2"],"prefix":"10.1097","volume":"37","author":[{"given":"David A.","family":"Zuelzer","sequence":"first","affiliation":[{"name":"Department of Orthopaedic and Sports Medicine, University of Kentucky, Lexington, KY; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lunden","family":"Ryan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic and Sports Medicine, University of Kentucky, Lexington, KY; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Westbrooks","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic and Sports Medicine, University of Kentucky, Lexington, KY; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7460-454X","authenticated-orcid":false,"given":"Milton L. \u201cChip\u201d","family":"Routt","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, Houston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/S0030-5898(05)70294-7","article-title":"Biomechanics of pelvic fixation","volume":"28","author":"Simonian","year":"1997","journal-title":"Orthop Clin North Am"},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/S0030-5898(05)70295-9","article-title":"Stabilization of pelvic ring disruptions","volume":"28","author":"Chip Routt","year":"1997","journal-title":"Orthop Clin North Am"},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","article-title":"Early results of percutaneous iliosacral screws placed with the patient in the supine position","volume":"9","author":"Routt","year":"1995","journal-title":"J Orthop Trauma"},{"issue":"suppl 2","key":"R4-20250614","doi-asserted-by":"crossref","first-page":"B19","DOI":"10.1016\/S0020-1383(99)90004-9","article-title":"Unstable pelvic ring disruptions in unstable patients","volume":"30","author":"Kregor","year":"1999","journal-title":"Injury"},{"issue":"suppl 1","key":"R5-20250614","doi-asserted-by":"crossref","first-page":"SA33","DOI":"10.1016\/S0020-1383(01)00059-6","article-title":"Percutaneous management of unstable pelvic ring disruptions","volume":"32","author":"Barei","year":"2001","journal-title":"Injury"},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/BOT.0b013e3181e47fad","article-title":"Transiliac-transsacral screws for posterior pelvic stabilization","volume":"25","author":"Gardner","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.injury.2012.10.028","article-title":"Posterior iliac crescent fracture-dislocation: what morphological variations are amenable to iliosacral screw fixation?","volume":"44","author":"Calafi","year":"2013","journal-title":"Injury"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"103213","DOI":"10.1016\/j.otsr.2022.103213","article-title":"Screw misplacement in percutaneous posterior pelvic iliosacral screwing with and without navigation: a prospective clinical study of 174 screws in 127 patients","volume":"108","author":"Boudissa","year":"2022","journal-title":"Orthop Traumatol Surg Res"},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s00068-018-0990-z","article-title":"Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures","volume":"46","author":"Berger-Groch","year":"2020","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1007\/s00264-010-1092-7","article-title":"Factors influencing the accuracy of iliosacral screw placement in trauma patients","volume":"35","author":"Grossterlinden","year":"2011","journal-title":"Int Orthop"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s00402-018-3055-1","article-title":"Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation","volume":"139","author":"Takao","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1007\/s00264-017-3447-9","article-title":"Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series","volume":"41","author":"Shaw","year":"2017","journal-title":"Int Orthop"},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1097\/BOT.0000000000001796","article-title":"Multidimensional pelvic fluoroscopy: a new and novel technique for assessing safety and accuracy of percutaneous iliosacral screw fixation","volume":"34","author":"Shaw","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1097\/BOT.0000000000000708","article-title":"A useful preoperative planning technique for transiliac-transsacral screws","volume":"31","author":"Lucas","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s10195-015-0363-x","article-title":"Correlating preoperative imaging with intraoperative fluoroscopy in iliosacral screw placement","volume":"16","author":"Eastman","year":"2015","journal-title":"J Orthop Traumatol"},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"1947","DOI":"10.2106\/JBJS.I.01580","article-title":"Pelvic inlet and outlet radiographs redefined","volume":"92","author":"Ricci","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R17-20250614","first-page":"204","article-title":"Iliosacral screw placement: are uniplanar changes realistic based on standard fluoroscopic imaging?","volume":"71","author":"Graves","year":"2011","journal-title":"J Trauma"},{"key":"R18-20250614","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/j.injury.2008.01.049","article-title":"Is the lateral sacral fluoroscopic view essential for accurate percutaneous sacroiliac screw insertion? An experimental study","volume":"39","author":"Giannoudis","year":"2008","journal-title":"Injury"},{"key":"R19-20250614","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1097\/BOT.0b013e318137948d","article-title":"The effect of C-arm malrotation on iliosacral screw placement","volume":"21","author":"Wolinsky","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R20-20250614","doi-asserted-by":"crossref","first-page":"e120","DOI":"10.2106\/JBJS.M.00895","article-title":"Anatomic determinants of sacral dysmorphism and implications for safe iliosacral screw placement","volume":"96","author":"Kaiser","year":"2014","journal-title":"J Bone Joint Surg"},{"key":"R21-20250614","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/BOT.0000000000002380","article-title":"Defining sacral dysmorphism: what size corridor precludes transsacral screw placement","volume":"36","author":"Woods","year":"2022","journal-title":"J Orthop Trauma"},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"e122","DOI":"10.1097\/BOT.0b013e31826046b0","article-title":"Lateral sacral imaging in the morbidly obese","volume":"27","author":"Miller","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1097\/00005131-199604000-00005","article-title":"Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study","volume":"10","author":"Chip","year":"1996","journal-title":"J Orthop Trauma"},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1007\/s00064-019-0612-x","article-title":"Preoperative planning and safe intraoperative placement of iliosacral screws under fluoroscopic control","volume":"31","author":"Krappinger","year":"2019","journal-title":"Oper Orthop Traumatol"},{"key":"R25-20250614","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1007\/s00402-013-1788-4","article-title":"Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis","volume":"133","author":"Zwingmann","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"103210","DOI":"10.1016\/j.otsr.2022.103210","article-title":"Iliosacral screw fixation of pelvic ring disruption with tridimensional patient-specific template guidance","volume":"108","author":"Liu","year":"2022","journal-title":"Orthop Traumatol Surg Res"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002698","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:03:30Z","timestamp":1749924210000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002698"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002698","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"2023-09-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}