{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T07:39:09Z","timestamp":1774424349629,"version":"3.50.1"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To evaluate 1 manufacturer's titanium intramedullary lengthening nail (ILN) for radiographic evidence of adverse tissue reactions similar to those in their stainless-steel ILN that was recalled in 2021, with specific outcomes of (1) incidence of periosteal reaction and osteolysis and (2) adverse tissue reaction-related device failures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Radiographic review of consecutive patients with \u22651-year clinical follow-up who received 1 manufacturer's ILNs implanted in the femur and\/or tibia from February 2012 to July 2021.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Single tertiary-care center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Two hundred twenty-six limbs with titanium ILNs and 57 limbs with stainless-steel ILNs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Precice titanium ILN (NuVasive Specialized Orthopedics, San Diego, CA) and Stryde stainless-steel ILN (NuVasive Specialized Orthopedics).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Radiographic outcome data and complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of 226 limbs with titanium ILNs, 160 (70.8%) had periosteal reaction, and 2 (0.9%) had osteolysis. Periosteal reaction and osteolysis rates in stainless-steel ILNs (57 limbs) were 39% and 26%, respectively. No adverse tissue reaction-related device failures were noted with titanium. Several other complications presented, notably hip and\/or knee tissue contracture (141), consolidation problems (8), and needing peroneal nerve decompression (14).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Osteolysis incidence was substantially less among the titanium population, supporting the claim that observed osteolysis in the stainless-steel cohort was attributed to its construct. On average, periosteal reaction was radiographically appreciated later in patients with titanium than stainless steel. Further study is needed to confirm this finding.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002709","type":"journal-article","created":{"date-parts":[[2023,11,17]],"date-time":"2023-11-17T05:07:07Z","timestamp":1700197627000},"page":"664-668","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Incidence of Focal Osteolysis in a Titanium Limb-Lengthening Device: A Comparison to a Stainless-Steel Model"],"prefix":"10.1097","volume":"37","author":[{"given":"Oliver C.","family":"Sax","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Larysa P.","family":"Hlukha","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyle A.","family":"Kowalewski","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Davidson College, Davidson, NC."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandeep S.","family":"Bains","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeremy A.","family":"Dubin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John E.","family":"Herzenberg","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Assayag","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip K.","family":"McClure","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/00003086-198901000-00038","article-title":"The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preservation","volume":"238","author":"Ilizarov","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/00003086-198902000-00029","article-title":"The tension-stress effect on the genesis and growth of tissues: Part II. The influence of the rate and frequency of distraction","volume":"239","author":"Ilizarov","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"2923","DOI":"10.1007\/s11999-008-0509-8","article-title":"Limb lengthening and then insertion of an intramedullary nail: a case-matched comparison","volume":"466","author":"Rozbruch","year":"2008","journal-title":"Clin Orthop Relat Res"},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/00003086-199001000-00011","article-title":"Problems, obstacles, and complications of limb lengthening by the Ilizarov technique","volume":"250","author":"Paley","year":"1990","journal-title":"Clin Orthop Relat Res"},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/00003086-199710000-00023","article-title":"A fully implantable motorized intramedullary nail for limb lengthening and bone transport","volume":"343","author":"Baumgart","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"R6-20250614","first-page":"1058","article-title":"Fully implantable intramedullary distraction nail in shortening deformity and bone defects. Spectrum of indications [in German]","volume":"28","author":"Baumgart","year":"1999","journal-title":"Orthopade"},{"key":"R7-20250614","first-page":"e21.00101","article-title":"Biopsyproven focal osteolysis in a stainless-steel limb-lengthening device: a report of three cases","volume":"5","author":"Sax","year":"2021","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1302\/2046-3758.107.BJR-2021-0146.R1","article-title":"Focal osteolysis and corrosion at the junction of Precice Stryde intramedullary lengthening device: preliminary clinical, radiological, and metallurgic analysis of 57 lengthened segments","volume":"10","author":"Frommer","year":"2021","journal-title":"Bone Joint Res"},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.2106\/JBJS.RVW.16.00118","article-title":"Evaluation and treatment of femoral osteolysis following total hip arthroplasty","volume":"5","author":"Gittings","year":"2017","journal-title":"JBJS Rev"},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1186\/s40824-018-0144-8","article-title":"Recent updates for biomaterials used in total hip arthroplasty","volume":"22","author":"Hu","year":"2018","journal-title":"Biomater Res"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"e258","DOI":"10.5435\/JAAOS-D-16-00685","article-title":"Evaluation and treatment of patients with acetabular osteolysis after total hip arthroplasty","volume":"27","author":"Sheth","year":"2019","journal-title":"J Am Acad Orthop Surg"},{"issue":"suppl l","key":"R12-20250614","doi-asserted-by":"crossref","first-page":"S206","DOI":"10.1097\/00003086-199608001-00018","article-title":"Metal versus polyethylene wear particles in total hip replacements. A review","volume":"329","author":"Doorn","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/00003086-199707000-00016","article-title":"Wear particulate species and bone loss in failed total joint arthroplasties","volume":"340","author":"Kadoya","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/S0883-5403(08)80093-9","article-title":"Tissue response in relation to type of wear particles around failed hip arthroplasties","volume":"5","author":"Howie","year":"1990","journal-title":"J Arthroplasty"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1302\/0301-620X.103B6.BJJ-2020-2165.R1","article-title":"Early results from a single centre's experience with the Stryde nail: a cause for concern","volume":"103-B","author":"Iliadis","year":"2021","journal-title":"Bone Joint J"},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1080\/17453674.2021.1927506","article-title":"The Stryde limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants","volume":"92","author":"Jellesen","year":"2021","journal-title":"Acta Orthop"},{"key":"R17-20250614","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1080\/17453674.2021.1903278","article-title":"Pain, osteolysis, and periosteal reaction are associated with the Stryde limb lengthening nail: a nationwide cross-sectional study","volume":"92","author":"R\u00f6lfing","year":"2021","journal-title":"Acta Orthop"},{"key":"R19-20250614","doi-asserted-by":"crossref","first-page":"19","DOI":"10.4103\/jllr.jllr_17_21","article-title":"Risk factors for focal osteolysis in a stainless-steel limb-lengthening device","volume":"7","author":"Sax","year":"2021","journal-title":"J Limb Lengthening Reconstr"},{"key":"R20-20250614","doi-asserted-by":"crossref","first-page":"537","DOI":"10.2106\/00004623-200104000-00008","article-title":"Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail","volume":"83","author":"Jones","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1302\/2046-3758.77.BJR-2017-0359.R1","article-title":"A retrieval analysis of the titanium intramedullary limb lengthening system","volume":"7","author":"Panagiotopoulou","year":"2018","journal-title":"Bone Joint Res"},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"103501","DOI":"10.1016\/j.otsr.2022.103501","article-title":"No osteolysis at the telescopic junction of 128 Fitbone lengthening nails","volume":"109","author":"Leblanc","year":"2023","journal-title":"Orthop Traumatol Surg Res"},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1016\/j.biomaterials.2004.04.035","article-title":"The role of macrophages in osteolysis of total joint replacement","volume":"26","author":"Ingham","year":"2005","journal-title":"Biomaterials"},{"key":"R25-20250614","first-page":"1515","article-title":"Early osteolysis following second-generation metal-on-metal hip replacement","volume":"87","author":"Park","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"2297","DOI":"10.1016\/S0142-9612(98)00140-9","article-title":"Polyethylene particles of a \u201ccritical size\u201d are necessary for the induction of cytokines by macrophages in vitro","volume":"19","author":"Green","year":"1998","journal-title":"Biomaterials"},{"key":"R27-20250614","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1054\/arth.2002.33664","article-title":"A literature review of the association between wear rate and osteolysis in total hip arthroplasty","volume":"17","author":"Dumbleton","year":"2002","journal-title":"J Arthroplasty"},{"key":"R28-20250614","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1302\/0301-620X.103B.BJJ-2021-0549.R1","article-title":"Radiographs of 366 removed limb-lengthening nails reveal differences in bone abnormalities between different nail types","volume":"103-B","author":"Iobst","year":"2021","journal-title":"Bone Joint J"},{"key":"R29-20250614","first-page":"860","article-title":"Does focal osteolysis in a Precice Stryde intramedullary lengthening nail resolve after explantation","volume":"9","author":"Sax","year":"2022","journal-title":"Children (Basel)"},{"key":"R30-20250614","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1002\/jbm.b.30904","article-title":"Histomorphometric analysis of the intramedullary bone response to titanium particles in wild-type and IL-1R1 knock-out mice: a preliminary study","volume":"84","author":"Bragg","year":"2008","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R31-20250614","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.jmbbm.2012.08.016","article-title":"Load-bearing in cortical bone microstructure: selective stiffening and heterogeneous strain distribution at the lamellar level","volume":"17","author":"Katsamenis","year":"2013","journal-title":"J Mech Behav Biomed Mater"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002709","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:02:43Z","timestamp":1749924163000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002709"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":29,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002709","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"2023-09-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}