{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T04:55:51Z","timestamp":1784004951745,"version":"3.55.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Formerly poor bone stock and periprosthetic fractures used to jeopardize monoaxial constructs. Polyaxial locking screws have substantially supported those particular fixation constructs. However, those systems rely on complex alignment between the screw head and the plate hole. This study aimed to investigate the mechanical properties of several polyaxial systems and to correlate these parameters with the screw head and the plate hole engagement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Polyaxial locking systems were tested with screws inserted into the corresponding plates at various angles (0, 5, 10, and 15 degrees). A micro-computed tomography (micro-CT) scan of the plate hole and screw head interface with the quantification of average thread engagement (ATE) was performed before destructive tests. The screw\u2013plate interface of each system was tested in a cantilever bending setup. Representative screws and plates were also examined by scanning electron microscope.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The standard insertion at 0 degrees sustained the greatest maximum bending strength in all analyzed systems. Point-loading thread-in and cut-in screws inserted off-axis showed a significant reduction in bending strength (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.041) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). By contrast, locking cap screws maintained similar bending strength with disregard to the angle of insertion (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.4849). A micro-CT analysis confirmed that the ATE of point-loading thread-in, cut-in, and locking cap screws was significantly reduced when placed off-axis (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.005) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.002) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). The locking cap mechanisms maintained the highest ATE among all analyzed systems.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The mechanical performance of polyaxial locking plates usually comes at the price of reduced bending strength. Surgeons should limit polyaxial insertions depending on the particular system's characteristics.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002712","type":"journal-article","created":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T04:00:56Z","timestamp":1697688056000},"page":"e466-e473","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Biomechanical Evaluation of Variable-Angle Locking Systems. A Micro-CT Analysis"],"prefix":"10.1097","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8200-742X","authenticated-orcid":false,"given":"Jakub","family":"Glowacki","sequence":"first","affiliation":[{"name":"Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Pozna\u0144 University of Medical Sciences, Poznan, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Bartkowiak","sequence":"additional","affiliation":[{"name":"Institute of Mechanical Technology, Poznan University of Technology, Poznan, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bartosz","family":"Gapinski","sequence":"additional","affiliation":[{"name":"Institute of Mechanical Technology, Poznan University of Technology, Poznan, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Paczos","sequence":"additional","affiliation":[{"name":"Institute of Applied Mechanics, Poznan University of Technology, Poznan, Poland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patryk","family":"Mietlinski","sequence":"additional","affiliation":[{"name":"Institute of Mechanical Technology, Poznan University of Technology, Poznan, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pawel","family":"Zawadzki","sequence":"additional","affiliation":[{"name":"Institute of Mechanical Technology, Poznan University of Technology, Poznan, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukasz","family":"Lapaj","sequence":"additional","affiliation":[{"name":"Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Pozna\u0144 University of Medical Sciences, Poznan, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/BOT.0b013e3181a567c8","article-title":"Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures","volume":"23","author":"Otto","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s00256-010-0964-7","article-title":"Limb shortening in the course of solitary bone cyst treatment\u2014a comparative study","volume":"40","author":"Glowacki","year":"2011","journal-title":"Skeletal Radiol."},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00256-009-0701-2","article-title":"Evaluation of volume and solitary bone cyst remodeling using conventional radiological examination","volume":"39","author":"Glowacki","year":"2010","journal-title":"Skeletal Radiol."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1186\/1471-2474-15-369","article-title":"Mono\u2014versus polyaxial locking plates in distal femur fractures\u2014a biomechanical comparison of the non-contact-bridging\u2014(NCB) and the PERILOC-plate","volume":"15","author":"El-Zayat","year":"2014","journal-title":"BMC Musculoskelet Disord."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/QAI.0b013e3181a25368","article-title":"Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model","volume":"23","author":"Cullen","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1097\/BOT.0b013e31818896b3","article-title":"Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison","volume":"22","author":"Wilkens","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1097\/BOT.0000000000000391","article-title":"Early mechanical failures of the Synthes variable angle locking distal femur plate","volume":"30","author":"Tank","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1007\/s11751-013-0182-7","article-title":"Results in treatment of distal femur fractures using polyaxial locking plate","volume":"9","author":"Pascarella","year":"2014","journal-title":"Strateg Trauma Limb Reconstr."},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1007\/s00264-013-2210-0","article-title":"Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial","volume":"38","author":"Hanschen","year":"2014","journal-title":"Int Orthop."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1097\/BOT.0b013e31821d7a56","article-title":"Pitfalls in the application of distal femur plates for fractures","volume":"25","author":"Collinge","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1097\/00005131-200409000-00015","article-title":"Failure of less invasive stabilization system plates in the distal femur: a report of four cases","volume":"18","author":"Button","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1016\/j.injury.2013.06.013","article-title":"A biomechanical study comparing polyaxial locking screw mechanisms","volume":"44","author":"Hebert-Davies","year":"2013","journal-title":"Injury"},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1515\/bmt-2012-0105","article-title":"Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius plates","volume":"58","author":"Mehling","year":"2013","journal-title":"Biomed Technik\/Biomedical Eng."},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.1016\/j.injury.2016.06.001","article-title":"The biomechanical cost of variable angle locking screws","volume":"47","author":"Tidwell","year":"2016","journal-title":"Injury"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"186","DOI":"10.3415\/VCOT-12-03-0043","article-title":"The effect of screw angulation and insertion torque on the push-out strength of polyaxial locking screws and the single cycle to failure in bending of polyaxial locking plates","volume":"26","author":"Bufkin","year":"2013","journal-title":"Vet Comp Orthop Traumatol."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.clinbiomech.2009.06.004","article-title":"The strength of polyaxial locking interfaces of distal radius plates","volume":"24","author":"Hoffmeier","year":"2009","journal-title":"Clin Biomech."},{"key":"R17-20250614","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.2106\/JBJS.RVW.17.00049","article-title":"Not all polyaxial locking screw Technologies are created equal: a systematic review of the literature","volume":"6","author":"Schoch","year":"2018","journal-title":"JBJS Rev."},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1055\/s-0040-1709728","article-title":"How do the locking screws lock? A micro-CT study of 3.5-mm locking screw mechanism","volume":"33","author":"Kaczmarek","year":"2020","journal-title":"Vet Comp Orthop Traumatol."},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1055\/s-0042-1750431","article-title":"What is the cost of off-Axis insertion of locking screws? A biomechanical comparison of a 3.5 mm fixed-angle and 3.5 mm variable-angle stainless steel locking plate systems","volume":"35","author":"Kaczmarek","year":"2022","journal-title":"Vet Comp Orthop Traumatol."},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1147\/sj.41.0025","article-title":"Algorithm for computer control of a digital plotter","volume":"4","author":"Bresenham","year":"1965","journal-title":"IBM Syst J."},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1111\/j.1532-950X.2014.12095.x","article-title":"In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model","volume":"43","author":"Malenfant","year":"2014","journal-title":"Vet Surg."},{"key":"R27-20250614","doi-asserted-by":"crossref","first-page":"4529","DOI":"10.3892\/mmr.2016.5793","article-title":"Quantification of the asymmetric migration of the lipophilic dyes, DiO and DiD, in homotypic co-cultures of chondrosarcoma SW-1353 cells","volume":"14","author":"Lehmann","year":"2016","journal-title":"Mol Med Rep."},{"key":"R28-20250614","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1097\/01.ta.0000195462.53525.0c","article-title":"Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques","volume":"60","author":"Fulkerson","year":"2006","journal-title":"J Trauma"},{"key":"R29-20250614","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1097\/SAP.0000000000000850","article-title":"Complication rate comparing variable angle distal locking plate to fixed angle plate fixation of distal radius fractures","volume":"77","author":"Mehrzad","year":"2016","journal-title":"Ann Plast Surg."},{"key":"R30-20250614","doi-asserted-by":"crossref","first-page":"614","DOI":"10.2106\/JBJS.F.00510","article-title":"Results of polyaxial locked-plate fixation of periarticular fractures of the knee","volume":"89","author":"Haidukewych","year":"2007","journal-title":"J bone Joint Surg."},{"key":"R31-20250614","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/00005131-200409000-00002","article-title":"Locked internal fixator: sensitivity of screw\/plate stability to the correct insertion angle of the screw","volume":"18","author":"K\u00e4\u00e4b","year":"2004","journal-title":"J Orthop Trauma"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002712","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:03:32Z","timestamp":1749924212000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002712"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002712","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"2023-10-04","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}