{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T00:26:14Z","timestamp":1785803174251,"version":"3.56.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression type 1 (LC1) injuries.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective comparative study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 trauma center<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient Selection Criteria:<\/jats:title>\n            <jats:p>Stress-positive minimally displaced (&lt;1 cm) LC1 pelvic ring injuries treated with retrograde rami screws.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcome Measures and Comparisons:<\/jats:title>\n            <jats:p>Loss of fixation, defined as &gt;5 mm of pelvic fracture displacement based on the radiographic tear-drop distance or &gt;5 mm of implant displacement on follow-up radiographs; revision surgery for loss of fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>Thirty-eight patients with 40 retrograde rami screws were analyzed. Median patient age was 64 years (interquartile range 42.5\u201373.3 years), 71.1% (n = 27\/38) were female, and 52.6% (n = 20\/38) of injuries were secondary to low-energy mechanisms. Loss of fixation occurred in 17.5% (n = 7\/40) of screws with 10% (n = 4\/40) requiring revision surgery. On univariate analysis, patients who had a loss of fixation were more likely to have greater dynamic displacement on stress radiographs (22.0 vs. 15.2 mm; median difference 5.6 mm, confidence interval [CI] \u221219.2 to 10.3; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.04), unicortical rami screws (71.4% vs. 9.1%; proportional difference 62.3%, CI 8.8%\u201322.6%; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.001), and partially threaded rami screws (71.4% vs. 21.2%; proportional difference 50.2%, CI 10.0%\u201377.6%; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.01). The remaining variables had no observed association (<jats:italic toggle=\"yes\">P<\/jats:italic> \u2265 0.05) with loss of fixation, including age, sex, body mass index, energy of injury mechanism, tobacco use, American Society of Anesthesiologist score, sacral fracture type, distal rami fractures, rami comminution, number of sacral screws, fully threaded sacral screws, transsacral screws, or rami screw diameter. On multivariate analysis, only unicortical rami screws (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.01) remained associated with loss of fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Retrograde rami screws had a high rate of loss of fixation in minimally displaced LC1 pelvic ring injuries, and this was associated with unicortical screws. These screws should be avoided when possible.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>LEVEL OF EVIDENCE:<\/jats:title>\n            <jats:p>Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002756","type":"journal-article","created":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T02:00:25Z","timestamp":1704420025000},"page":"215-219","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries"],"prefix":"10.1097","volume":"38","author":[{"given":"Nicholas J.","family":"Tucker","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Stacey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye Joon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge","family":"DeLeon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raveesh","family":"Richard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Austin","family":"Heare","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Mauffrey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8262-4065","authenticated-orcid":false,"given":"Joshua A.","family":"Parry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1097\/BOT.0000000000001973","article-title":"Factors associated with failure of superior pubic ramus screws","volume":"35","author":"Comadoll","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/BOT.0000000000001942","article-title":"Low superior pubic ramus screw failure rate with combined anterior and posterior pelvic ring fixation","volume":"35","author":"Shieh","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/BOT.0000000000002407","article-title":"Anterior pelvic ring fracture pattern predicts subsequent displacement in lateral compression sacral fractures","volume":"36","author":"Ellis","year":"2022","journal-title":"J Orthop Trauma"},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1097\/BOT.0000000000002403","article-title":"Rami comminution is associated with displacement of minimally displaced lateral compression type 1 injuries on lateral stress radiographs","volume":"36","author":"Hadeed","year":"2022","journal-title":"J Orthop Trauma"},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1007\/s00590-021-02935-z","article-title":"Lateral compression type 1 (LC1) pelvic ring injuries: a spectrum of fracture types and treatment algorithms","volume":"31","author":"Kur\u0161umovi\u0107","year":"2021","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/BOT.0000000000002519","article-title":"Combined anterior-posterior versus posterior-only fixation of stress-positive minimally displaced lateral compression type 1 (LC1) pelvic ring injuries","volume":"37","author":"Tucker","year":"2023","journal-title":"J Orthop Trauma"},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1007\/s00590-022-03373-1","article-title":"The lateral stress radiograph: an effective alternative to examination under anesthesia for identifying occult instability in minimally displaced lateral compression pelvic ring injuries","volume":"33","author":"Tucker","year":"2022","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1097\/BOT.0000000000001805","article-title":"The lateral stress radiograph identifies occult instability of lateral compression pelvic ring injuries without sedation","volume":"34","author":"Parry","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"1953","DOI":"10.1007\/s00590-022-03377-x","article-title":"The effect of pelvic ring rotation and tilt on the radiographic teardrop distance: an important consideration in the assessment of dynamic displacement on stress radiographs","volume":"33","author":"Tucker","year":"2022","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1097\/BOT.0b013e3181f8be33","article-title":"OTA highlight paper predicting future displacement of nonoperatively managed lateral compression sacral fractures: can it Be done?","volume":"25","author":"Bruce","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R11-20250614","article-title":"Fracture displacement of lateral compression type 1 (LC1) Pelvic Ring Injuries: which measurement methods are reliable and does displacement correlate with adverse events?","year":"2023","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s00590-020-02843-8","article-title":"Standardizing statistics and data reporting in orthopaedic research","volume":"31","author":"Strage","year":"2021","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/BOT.0b013e318162ab6e","article-title":"Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure?","volume":"22","author":"Starr","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.injury.2019.12.018","article-title":"Minimal-invasive stabilization of anterior pelvic ring fractures with retrograde transpubic screws","volume":"51","author":"Rommens","year":"2020","journal-title":"Injury"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1007\/s00264-023-05710-3","article-title":"Evaluation of cannulated compression headless screws as an alternative implant for superior pubic ramus fracture fixation: a biomechanical study","volume":"47","author":"Berk","year":"2023","journal-title":"Int Orthop"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002756","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:02:13Z","timestamp":1749924133000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002756"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002756","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"2023-12-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}