{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T13:05:43Z","timestamp":1764853543967,"version":"3.46.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","funder":[{"DOI":"10.13039\/100008894","name":"Stryker","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008894","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>To compare time, fluoroscopic utilization, and number of misses for placement of far interlocking screws in tibial and femoral nails using a targeting arm (Targeter) versus perfect circle technique (Control).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Prospective randomized controlled trial.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Single-center, large, urban, level 1 trauma center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient Selection Criteria:<\/jats:title>\n                    <jats:p>Patients \u226518 years old with a tibia or femur fracture (AO\/OTA 31A, 32, or 42) treated with an intramedullary nail from November 2022 to December 2023 were included.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcome Measures and Comparisons:<\/jats:title>\n                    <jats:p>The main outcome measures were number of fluoroscopy images taken and average time elapsed to place each far interlocking screw. The far interlocking screws were defined as the screws farthest from the insertion handle. Comparisons were made between the Targeter and Control cohorts in terms of number of fluoroscopy images taken and average time elapsed to place each far interlocking screw, and the number of misses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Thirty-one patients were randomized to Targeter and 31 to Control. There were no significant differences between the Targeter and Control cohorts in patient sex (58.6% vs. 54.5% women,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.75), age (range (20\u201390 vs. 18\u201391, mean 52.7 vs. 54.2,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.81), BMI (mean 25.9 vs. 26.2,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.66), AO classification (13.8% vs. 36.4% 31 A, 37.9% vs. 21.2% 32, 48.2% vs. 42.4% 42,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.20), or number of open fractures (13.8% vs. 7.1%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.67) between the 2 cohorts. For the Targeter group, fewer images were used than Controls for the first (15.0 vs. 22.5,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002), second (11.5 vs. 18.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.006), and combined first and second (25.0 vs. 39.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001) screws. There was no difference between the Targeter and Control cohorts in the time it took to place the first (6.3 vs. 7.3 minutes,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.31), second (5.8 vs. 6.2 minutes,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.63), or combined first and second (11.9 vs. 13.7 minutes,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.63) screws. In the Control cohort, there was 1 missed screw (1.4%, n = 69). In the Targeter cohort, there were 3 missed screws (5.4%, n = 56), a 4-fold increase that did not reach statistical significance (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.31).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>\n                      In this prospective randomized controlled trial, a targeting arm decreased the number of fluoroscopic images used for all far interlocking screws as compared with the perfect circle technique without a reduction in time. There was a trend toward increased misses in the Targeter cohort (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.31). Although the reduction in radiation exposure may have a cumulative beneficial effect during the course of a surgeon's career, the trend of increased misses with the Targeter should be taken into account.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>LEVEL OF EVIDENCE:<\/jats:title>\n                    <jats:p>Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000003066","type":"journal-article","created":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T19:00:11Z","timestamp":1756839611000},"page":"631-638","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Targeting Arm for Interlocking Screws Reduces Radiation Exposure: Results of a Prospective Randomized Controlled Trial"],"prefix":"10.1097","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-2916-9197","authenticated-orcid":false,"given":"Mackinzie","family":"Stanley","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"},{"name":"Department of Surgery, University of Arizona College of Medicine\u2014Phoenix, Phoenix, AZ; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"},{"name":"Department of Orthopaedic Surgery, McGill University Health Center, Montreal, QC, Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Garlich","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milton","family":"Little","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geoffrey","family":"Marecek","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Moon","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Vrahas","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carol","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA ;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20251204","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.whi.2015.05.005","article-title":"Cancer prevalence among a cross-sectional survey of female orthopedic, urology, and plastic surgeons in the United States","volume":"25","author":"Chou","year":"2015","journal-title":"Womens Health Issues"},{"key":"R2-20251204","first-page":"e22.00031","article-title":"Increased prevalence of breast and all-cause cancer in female orthopaedic surgeons","volume":"6","author":"Chou","year":"2022","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"R3-20251204","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1089\/jwh.2011.3342","article-title":"Increased breast cancer prevalence among female orthopedic surgeons","volume":"21","author":"Chou","year":"2012","journal-title":"J Womens Health"},{"key":"R4-20251204","doi-asserted-by":"crossref","first-page":"1727","DOI":"10.1016\/j.injury.2017.04.041","article-title":"The Great Unknown\u2014a systematic literature review about risk associated with intraoperative imaging during orthopaedic surgeries","volume":"48","author":"Matityahu","year":"2017","journal-title":"Injury"},{"key":"R6-20251204","doi-asserted-by":"crossref","first-page":"268","DOI":"10.5435\/JAAOS-D-16-00342","article-title":"Radiation exposure and health risks for orthopaedic surgeons","volume":"26","author":"Hayda","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"key":"R7-20251204","doi-asserted-by":"crossref","first-page":"e0060","DOI":"10.2106\/JBJS.RVW.19.00060","article-title":"Radiation exposure in orthopaedics","volume":"8","author":"Frane","year":"2020","journal-title":"JBJS Rev."},{"key":"R8-20251204","first-page":"280","article-title":"Does electromagnetic guidance system superior to free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study","volume":"26","author":"Aslan","year":"2020","journal-title":"Turk J Trauma Emerg Surg"},{"key":"R9-20251204","doi-asserted-by":"crossref","first-page":"106326","DOI":"10.1016\/j.cmpb.2021.106326","article-title":"A novel dynamic electromagnetic tracking navigation system for distal locking of intramedullary nails","volume":"209","author":"Gao","year":"2021","journal-title":"Comput Methods Programs Biomed."},{"key":"R10-20251204","doi-asserted-by":"crossref","first-page":"e281","DOI":"10.1097\/BOT.0000000000000125","article-title":"Distal interlocking screw placement in the femur: free-hand versus electromagnetic assisted technique (Sureshot)","volume":"28","author":"Maqungo","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R11-20251204","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.injury.2013.09.023","article-title":"Insertion of distal locking screws of tibial intramedullary nails: a comparison between the free-hand technique and the SURESHOTTM Distal Targeting System","volume":"45","author":"Moreschini","year":"2014","journal-title":"Injury"},{"key":"R12-20251204","doi-asserted-by":"crossref","first-page":"4145","DOI":"10.2147\/IJGM.S321005","article-title":"A new accurate, simple and less radiation exposure device for distal locking of femoral intramedullary nails","volume":"14","author":"Gao","year":"2021","journal-title":"Int J Gen Med."},{"key":"R13-20251204","doi-asserted-by":"crossref","first-page":"e2110","DOI":"10.1002\/rcs.2110","article-title":"Implementation and performance evaluation of a drilling assistive device for distal locking of intramedullary nails","volume":"16","author":"Hsu","year":"2020","journal-title":"Int J Med Robot"},{"key":"R14-20251204","first-page":"78","article-title":"Mechanical aiming device for distal locking in femur nail-an undeveloped part of femur nail system","volume":"1","author":"Saket","year":"2023","journal-title":"J Orthop Clin Res"},{"key":"R15-20251204","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/S0020-1383(01)00100-0","article-title":"The AO distal locking aiming device an evaluation of efficacy and learning curve","volume":"32","author":"Pardiwala","year":"2001","journal-title":"Injury"},{"key":"R16-20251204","doi-asserted-by":"crossref","first-page":"113","DOI":"10.31080\/ASOR.2023.06.0803","article-title":"Distal locking of intramedullary nailing: current technology to improve accuracy, radiation exposure, and operative time","volume":"6","author":"Ulrich","year":"2023","journal-title":"Acta Sci Orthop"},{"key":"R17-20251204","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1016\/j.injury.2008.04.020","article-title":"Evaluation of the Stryker S2TM IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study","volume":"39","author":"Anastopoulos","year":"2008","journal-title":"Injury"},{"key":"R18-20251204","doi-asserted-by":"crossref","first-page":"e202215","DOI":"10.1001\/jamanetworkopen.2020.2215","article-title":"Effectiveness of iodophor vs chlorhexidine solutions for surgical site infections and unplanned reoperations for patients who underwent fracture repair: the PREP-IT master protocol","volume":"3","author":"Slobogean","year":"2020","journal-title":"JAMA Netw Open"},{"key":"R19-20251204","doi-asserted-by":"crossref","first-page":"m3800","DOI":"10.1136\/bmj.m3800","article-title":"Use of multiple period, cluster randomised, crossover trial designs for comparative effectiveness research","volume":"371","author":"Hemming","year":"2020","journal-title":"BMJ"},{"issue":"suppl 4","key":"R21-20251204","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/S0020-1383(01)00115-2","article-title":"Tibial intramedullary nail distal interlocking screw placement: comparison of the free-hand versus distally-based targeting device techniques","volume":"32","author":"Gugala","year":"2001","journal-title":"Injury"},{"key":"R20-20251204","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1007\/s11999-007-0036-z","article-title":"Distal locking of tibial nails: a new device to reduce radiation exposure","volume":"466","author":"Anastopoulos","year":"2008","journal-title":"Clin Orthop Relat Res"},{"key":"R25-20251204","first-page":"106","article-title":"Risk of Ionising radiation to trainee orthopaedic surgeons","volume":"78","author":"Khan","year":"2012","journal-title":"Acta Orthop Belg."},{"key":"R26-20251204","doi-asserted-by":"crossref","first-page":"2111","DOI":"10.1007\/s00590-022-03401-0","article-title":"The relevance of the number of distal locking planes and nail to canal ratio in bone healing after intramedullary nailing in tibial shaft fractures","volume":"33","author":"Garabano","year":"2022","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R27-20251204","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1667\/RR2629.1","article-title":"Studies of the mortality of atomic bomb survivors, report 14, 1950\u20132003: an overview of cancer and noncancer diseases","volume":"177","author":"Ozasa","year":"2012","journal-title":"Radiat Res."},{"key":"R28-20251204","first-page":"1","article-title":"Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102","volume":"37","author":"Valentin","year":"2007","journal-title":"Ann ICRP"},{"key":"R29-20251204","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1016\/j.amjcard.2012.12.060","article-title":"Brain and neck tumors among physicians performing interventional procedures","volume":"111","author":"Roguin","year":"2013","journal-title":"Am J Cardiol."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003066","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T13:00:58Z","timestamp":1764853258000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003066"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":25,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003066","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"type":"print","value":"0890-5339"},{"type":"electronic","value":"1531-2291"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"2025-08-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}