{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T23:04:33Z","timestamp":1775775873453,"version":"3.50.1"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12S","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Summary:<\/jats:title>\n                  <jats:p>Complex tibial plateau fractures continue to challenge orthopaedic surgeons because of the difficulty in obtaining an anatomic reduction of the joint, axial alignment of the articular segment, while avoiding complications. Despite overall good results, significant complications persist with internal fixation, particularly in cases with compromised soft tissues, open fractures, bone loss, extensive comminution, compartment syndrome, extensor mechanism disruption, or significant osteopenia. Circular external fixation offers advantages in these situations because of its unique biomechanics, adaptability, and percutaneous techniques. The method limits incisions to only those needed to optimize reduction. Fixation of the articular surface and metaphyseal region is by a combination of small-diameter lag screws and olive wires \u00b1 half pins. Fixation of the shaft is with half pins from 1 or 2 rings. The articular fixation block can be connected to the distal ring block by threaded rods, trauma struts, or hexapod struts. Extension of the frame across the knee is useful in selected cases to protect injured soft tissue or extensor mechanism, provide distraction, and prevent a flexion contracture. Excellent results have been achieved with this technique and may have a lower complication rate than internal fixation in complex injuries.<\/jats:p>","DOI":"10.1097\/bot.0000000000003068","type":"journal-article","created":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T14:01:43Z","timestamp":1763128903000},"page":"S14-S18","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Circular External Fixation in the Treatment of Complex Tibial Plateau Fractures"],"prefix":"10.1097","volume":"39","author":[{"given":"Kevin J.","family":"Perry","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. Spence","family":"Reid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20251114","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1097\/00005131-200411000-00001","article-title":"Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique","volume":"18","author":"Barei","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R2-20251114","doi-asserted-by":"crossref","first-page":"e196","DOI":"10.1097\/BOT.0b013e318284704e","article-title":"Risk factors of infection after ORIF of bicondylar tibial plateau fractures","volume":"27","author":"Morris","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R3-20251114","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/S0030-5898(20)31955-6","article-title":"High-energy fractures of the tibial plateau","volume":"25","author":"Watson","year":"1994","journal-title":"Orthop Clin North Am."},{"key":"R4-20251114","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/00003086-199808000-00012","article-title":"Treatment of complex lateral plateau fractures using Ilizarov techniques","volume":"353","author":"Watson","year":"1998","journal-title":"Clin Orthop Relat Res."},{"key":"R5-20251114","doi-asserted-by":"crossref","first-page":"2613","DOI":"10.2106\/JBJS.E.01416","article-title":"Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial","volume":"88","year":"2006","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20251114","first-page":"1043","article-title":"Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation","volume":"63","author":"Catagni","year":"2007","journal-title":"J Trauma."},{"key":"R7-20251114","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1302\/0301-620X.97B12.34635","article-title":"Ilizarov management of Schatzker IV to VI fractures of the tibial plateau: 105 fractures at a mean follow-up of 7.8 years","volume":"97-B","author":"Keightley","year":"2015","journal-title":"Bone Joint J."},{"key":"R8-20251114","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/S0030-5898(03)00080-4","article-title":"Hybrid external fixation for tibial plateau fractures: clinical and biomechanical correlation","volume":"33","author":"Watson","year":"2002","journal-title":"Orthop Clin North Am."},{"key":"R9-20251114","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1016\/j.jbiomech.2005.03.022","article-title":"Experimental model of tibial plateau fracture for biomechanical testing","volume":"39","author":"Ali","year":"2006","journal-title":"J Biomech."},{"key":"R10-20251114","doi-asserted-by":"crossref","first-page":"2080","DOI":"10.1002\/jor.20270","article-title":"Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures","volume":"24","author":"Ali","year":"2006","journal-title":"J Orthop Res."},{"key":"R11-20251114","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00005131-200101000-00003","article-title":"Safe placement of proximal tibial transfixation wires with respect to intracapsular penetration","volume":"15","author":"Reid","year":"2001","journal-title":"J Orthop Trauma."},{"key":"R12-20251114","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1097\/00005131-199905000-00002","article-title":"Safe extracapsular placement of proximal tibia transfixation pins","volume":"13","author":"DeCoster","year":"1999","journal-title":"J Orthop Trauma."},{"key":"R13-20251114","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1097\/00005131-199803000-00014","article-title":"Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators","volume":"12","author":"Hutson","year":"1998","journal-title":"J Orthop Trauma."},{"key":"R14-20251114","doi-asserted-by":"crossref","first-page":"355","DOI":"10.3928\/01477447-20060401-08","article-title":"High energy tibial plateau fractures treated with hybrid fixation: is knee bridging necessary?","volume":"29","author":"Katsenis","year":"2006","journal-title":"Orthopedics."},{"key":"R15-20251114","doi-asserted-by":"crossref","first-page":"111131","DOI":"10.1016\/j.injury.2023.111131","article-title":"Circular frame fixation of complex tibial plateau fractures in the elderly: functional and radiological outcomes for Schatzker V and VI type fractures","volume":"54","author":"Robinson","year":"2023","journal-title":"Injury."},{"key":"R16-20251114","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/00013611-200203000-00008","article-title":"Chapter 7: the treatment of proximal periarticular tibial fractures with Ilizarov fixators","volume":"17","author":"Hutson","year":"2002","journal-title":"Tech Orthop."},{"issue":"suppl 2 pt 1","key":"R17-20251114","doi-asserted-by":"crossref","first-page":"74","DOI":"10.2106\/JBJS.G.01165","article-title":"Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Surgical technique","volume":"91","author":"Hall","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R18-20251114","first-page":"e11277","article-title":"Ilizarov fixation method of tibia Plateau Fractures: a prospective observational study","volume":"12","author":"Baloch","year":"2020","journal-title":"Cureus."},{"issue":"suppl 6","key":"R19-20251114","doi-asserted-by":"crossref","first-page":"S81","DOI":"10.1016\/S0020-1383(17)30799-4","article-title":"Severe tibial plateau fractures (Schatzker V-VI): open reduction and internal fixation versus hybrid external fixation","volume":"48","author":"Bertrand","year":"2017","journal-title":"Injury."},{"key":"R20-20251114","doi-asserted-by":"crossref","first-page":"e0232911","DOI":"10.1371\/journal.pone.0232911","article-title":"Comparison between open reduction with internal fixation to circular external fixation for tibial plateau fractures: a systematic review and meta-analysis","volume":"15","author":"Li","year":"2020","journal-title":"PLoS One"},{"key":"R21-20251114","doi-asserted-by":"crossref","first-page":"105","DOI":"10.5005\/jp-journals-10080-1557","article-title":"A meta-analysis comparing external fixation against open reduction and internal fixation for the management of tibial plateau fractures","volume":"17","author":"Naja","year":"2022","journal-title":"Strategies Trauma Limb Reconstr."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003068","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T14:01:46Z","timestamp":1763128906000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003068"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":21,"journal-issue":{"issue":"12S","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003068","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"value":"0890-5339","type":"print"},{"value":"1531-2291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"2025-08-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}