{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T18:47:48Z","timestamp":1767984468572,"version":"3.49.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>To identify which intrapelvic structures may be injured in cases of intrapelvic migration of the guide wire used for head screw\/blade placement during cephalomedullary nail fixation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Retrospective review.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Single academic, level 1 orthopaedic trauma subspeciality unit in university hospital.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient Selection Criteria:<\/jats:title>\n                    <jats:p>Patients with contrast-enhanced computed tomography treated with cephalomedullary nail fixation for Arbeitsgemeinschaft f\u00fcr Osteosynthesefragen (AO)\/OTA type 31A1, 31A2, 31A3 fractures from December 2022 to July 2024.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcome Measures and Comparisons:<\/jats:title>\n                    <jats:p>The primary outcome measure of this study was the quantification of pelvic structures that are at risk of iatrogenic injury related to mispositioned\/over advanced guide wire. Six simulation scenarios were created with variations applied in the sagittal axis: neutral anteversion, 7.5-degree anteversion, and 7.5-degree retroversion. Each 3 scenario applied for penetration depths of 2 cm and 5 cm. In addition, the safe distance was recorded. All simulations and measurements were analyzed both pooled and comparatively based on sex and laterality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Eighty-eight patients were included in the analysis, 47 (53.4%) were female and 41 (46.6%) were male. The median age was 77.5 years (interquartile range 65\u201385). In 48 (54.5%) patients, measurements were performed on the right hip. In neutral version trajectory, penetration of 2 cm resulted in contact with anatomical structures in 78% of cases, increasing to 98% at 5 cm. With anteversion, the rates were 90% at 2 cm and 98% at 5 cm. With retroversion, the corresponding rates were 55% and 93%, respectively. The most frequently affected structures at 2 cm were the external iliac artery and vein (external iliac vein), whereas at 5 cm, the small intestine and colon were most involved structures in addition to external iliac artery and external iliac vein. Other at-risk structures included the uterus, bladder, internal iliac artery, and internal iliac vein at both penetration depths and uterine venous plexus at 5-cm penetration. Notably, injury to external iliac vessels was significantly more common in males under the neutral sagittal projection (63% vs. 34% at 2 cm and 63% vs. 36% at 5 cm) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05 for both depths). Safe distances were significantly greater in males across all simulations (12.6 cm vs. 11.4 cm in neutral version, 12.4 cm vs. 11.0 cm in anteversion, 12.2 cm vs. 10.9 cm in retroversion) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05 for all).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Intrapelvic mispositioning of the guide wire used for head screw\/blade placement during cephalomedullary nail fixation posed a substantial risk of iatrogenic injury to intrapelvic structures, and this risk increased further with deeper penetration. However, the clinical implications of such injuries remain unclear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>LEVEL OF EVIDENCE:<\/jats:title>\n                    <jats:p>Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000003080","type":"journal-article","created":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T17:01:15Z","timestamp":1758301275000},"page":"e33-e38","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Structures at Risk With Intrapelvic Guide Wire Migration During Cephalomedullary Fixation of Hip Fractures: CT-Based Analysis"],"prefix":"10.1097","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8937-6658","authenticated-orcid":false,"given":"Arman","family":"Vahabi","sequence":"first","affiliation":[{"name":"Ege University School of Medicine, Department of Orthopedics and Traumatology, \u0130zmir, Turkey;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3222-8192","authenticated-orcid":false,"given":"Yusuf Kerem","family":"Limon","sequence":"additional","affiliation":[{"name":"Akdeniz University School of Medicine, Department of Radiology, Independent Researcher, Antalya, Turkey; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8810-440X","authenticated-orcid":false,"given":"\u00c7a\u011fatay","family":"\u00d6ncel","sequence":"additional","affiliation":[{"name":"Ege University School of Medicine, Department of Orthopedics and Traumatology, \u0130zmir, Turkey;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1232-4195","authenticated-orcid":false,"given":"Mehmet Kemal","family":"G\u00fcrsoy","sequence":"additional","affiliation":[{"name":"Akdeniz University School of Medicine, Department of Orthopedics and Traumatology, Antalya, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8058-0364","authenticated-orcid":false,"given":"Kemal","family":"Aktu\u011flu","sequence":"additional","affiliation":[{"name":"Ege University School of Medicine, Department of Orthopedics and Traumatology, \u0130zmir, Turkey;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20260109","doi-asserted-by":"crossref","first-page":"111185","DOI":"10.1016\/j.injury.2023.111185","article-title":"Mechanical outcomes of the TFNA, InterTAN and IMHS intramedullary nailing systems for the fixation of proximal femur fractures","volume":"55","author":"McAleese","year":"2024","journal-title":"Injury"},{"key":"R2-20260109","doi-asserted-by":"crossref","first-page":"S41","DOI":"10.1097\/BOT.0000000000002670","article-title":"Trust but verify: design differences in the prevention of targeting errors in cephalomedullary nails","volume":"37","author":"Klima","year":"2023","journal-title":"J Orthop Trauma"},{"key":"R3-20260109","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/s00402-012-1674-5","article-title":"Relationship between distal screws and femoral arteries in closed hip nailing on computed tomography angiography","volume":"133","author":"Han","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R4-20260109","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1007\/s00402-011-1347-9","article-title":"Anatomical structures at risk with the proud retrograde femoral nail","volume":"131","author":"Clement","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"R5-20260109","doi-asserted-by":"crossref","first-page":"829","DOI":"10.2106\/00004623-200704000-00019","article-title":"Risk of superior gluteal nerve and gluteus medius muscle injury during femoral nail insertion","volume":"89","author":"Ozsoy","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20260109","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1016\/j.injury.2015.12.012","article-title":"Safe zone for the superficial femoral artery demonstrated on computed tomography angiography","volume":"47","author":"Narulla","year":"2016","journal-title":"Injury"},{"key":"R7-20260109","doi-asserted-by":"crossref","first-page":"3253","DOI":"10.1007\/s00264-021-05177-0","article-title":"Iatrogenic gluteus medius muscle insertion injury while trochanteric entry nailing due to trochanteric fractures: a comparative study in forty patients with gray-scale ultrasound and shear-wave elastography","volume":"45","author":"\u00c7\u00f6lbe","year":"2021","journal-title":"Int Orthop"},{"key":"R8-20260109","first-page":"27","article-title":"Injury to the superior gluteal artery during intramedullary fixation of a proximal femoral fracture\u2013a case report","volume":"9","author":"Fernandes","year":"2020","journal-title":"J Orthop Case Rep"},{"key":"R9-20260109","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/j.injury.2019.10.003","article-title":"Evaluation of the positional relationship between femoral arteries and distal screws in the proximal femoral intramedullary nail for preventing iatrogenic vascular injury","volume":"51","author":"Asano","year":"2020","journal-title":"Injury"},{"key":"R10-20260109","doi-asserted-by":"crossref","first-page":"37","DOI":"10.13107\/jocr.2023.v13.i11.3998","article-title":"Intraosseous retrieval of broken guide wire while fixing proximal femur fractures\u2013a report of 2 cases and review of literature","volume":"13","author":"Samant","year":"2023","journal-title":"J Orthop Case Rep"},{"key":"R11-20260109","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/CORR.0000000000002792","article-title":"Intramedullary nailing of intertrochanteric femoral fractures in a level 1 trauma center in Finland: what complications can be expected?","volume":"482","author":"L\u00e4hdesm\u00e4ki","year":"2024","journal-title":"Clin Orthop Relat Res"},{"key":"R12-20260109","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13018-018-0749-6","article-title":"Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures","volume":"13","author":"Nherera","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R13-20260109","doi-asserted-by":"crossref","first-page":"e18020","DOI":"10.7717\/peerj.18020","article-title":"Comparative analysis of radiological outcomes among cephalomedullary nails: helical, screw and winged screw","volume":"12","author":"Vahabi","year":"2024","journal-title":"PeerJ"},{"key":"R14-20260109","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.1097\/BOT.0000000000002665","article-title":"Failure of fixation in trochanteric hip fractures: does nail design matter?","volume":"37","author":"Davidson","year":"2023","journal-title":"J Orthop Trauma"},{"key":"R15-20260109","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1097\/BOT.0b013e3182693fdd","article-title":"Femoral version of the general population: does \u201cnormal\u201d vary by gender or ethnicity?","volume":"27","author":"Koerner","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R16-20260109","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/BOT.0000000000001969","article-title":"Analysis of computed tomography\u2013based technique for measuring femoral anteversion: implications for measuring rotation after femoral intramedullary nail insertion","volume":"35","author":"McAlister","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R17-20260109","first-page":"19417381251326575","article-title":"Sex- and age-specific review of flag football injuries in the United States: a 10-year analysis of national injury data","author":"Locke","year":"2025","journal-title":"Sports Health A Multidiscip Approach"},{"key":"R18-20260109","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1186\/s12245-025-00897-1","article-title":"Sports injuries in the emergency department: an observational study with a gender perspective","volume":"18","author":"Mallorqu\u00edn","year":"2025","journal-title":"Int J Emerg Med"},{"key":"R19-20260109","doi-asserted-by":"crossref","DOI":"10.1097\/CORR.0000000000003519","article-title":"What is the anatomic footprint of the anterolateral ligament of the knee? A race- and sex-based MRI analysis","author":"Huang","year":"2025","journal-title":"Clin Orthop Relat Res"},{"key":"R20-20260109","doi-asserted-by":"crossref","first-page":"111416","DOI":"10.1016\/j.injury.2024.111416","article-title":"Comparison of patient positions without traction table for proximal femoral nailing: supine, semilithotomy and lateral decubitus positions","volume":"55","author":"Unal","year":"2024","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003080","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T14:03:36Z","timestamp":1767967416000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003080"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003080","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"value":"0890-5339","type":"print"},{"value":"1531-2291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"2025-09-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}