{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T13:13:05Z","timestamp":1778850785233,"version":"3.51.4"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>To determine whether use of a mini C-arm increased emergency department (ED) efficiency and decreased patient radiation exposure and the frequency of repeat closed reductions, as compared with traditional postreduction radiographs in patients with isolated distal radius and ankle fracture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Retrospective chart review.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Academic Level 1 Trauma Center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient Selection Criteria:<\/jats:title>\n                    <jats:p>Adult patients with an isolated distal radius (OTA\/AO 2R3A2), bimalleolar or trimalleolar ankle (OTA\/AO 44B1) fractures requiring closed reduction by the orthopaedic surgery team in an academic level 1 trauma center ED from 2013 to 2023 were included. Patients with pathologic fractures were excluded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcome Measures and Comparisons:<\/jats:title>\n                    <jats:p>Closed reductions in which mini C-arm imaging was used were compared with those that used traditional postreduction radiographs. Total radiation exposure to the patient during the encounter (mGy), closed reduction radiation exposure (mGy), the number of repeated reductions in the ED requiring an additional analgesic\/anesthetic event and splint application, orthopaedic consult time, doctor visit to discharge time, and time under sedation (conscious or unconscious) were compared between the mini C-arm group and the traditional postreduction radiographs group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      A total of 199 subjects met inclusion criteria (81 ankle fractures and 118 distal radius fractures). For the mini C-arm group, the mean age was 59 years (range 25\u201393) and 58% of the patients were female (n = 14). For the traditional postreduction radiographs group, the mean age was 58 years (range 21\u201390) and 55% of the patients were female (n = 96). Use of a mini C-arm (16 ankle fractures and 8 distal radius fractures) versus traditional postreduction radiographs (65 ankle fractures and 110 distal radius fractures) resulted in significantly lower total radiation exposure, 0.9 mGy versus 0.4 mGy (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and closed reduction radiation exposure, 0.5 versus 0.1 mGy (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001); fewer repeated reductions, 65 versus 0 repeated reductions (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001); and shorter time from doctor visit to discharge, 6.2 versus 3.8 hours (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), orthopaedic consult time, 4.0 versus 1.7 hours (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and time under sedation, 37 versus 26 minutes (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.046).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>This study found that the use of a mini C-arm compared with traditional postreduction radiographs for distal radius and ankle fracture closed reductions improved ED efficiency and decreased patient radiation exposure and repeated closed reductions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>LEVEL OF EVIDENCE:<\/jats:title>\n                    <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000003147","type":"journal-article","created":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T14:00:22Z","timestamp":1769522422000},"page":"e128-e133","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Increased Efficiency With Use of a Mini C-Arm in Emergency Department Closed Reductions"],"prefix":"10.1097","volume":"40","author":[{"given":"Mara","family":"Bajic","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carolyn","family":"Meinerz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew","family":"Laprade","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Kleven","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peyton","family":"Keeling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven","family":"Cherney","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth","family":"Nolte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20260515","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.jht.2016.03.003","article-title":"Epidemiology of distal radius fractures and factors predicting risk and prognosis","volume":"29","author":"MacIntyre","year":"2016","journal-title":"J Hand Ther."},{"key":"R2-20260515","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1016\/j.jhsa.2018.02.015","article-title":"The effectiveness of mini-C-arm fluoroscopy for the closed reduction of distal radius fractures in adults: a randomized controlled trial","volume":"43","author":"Dailey","year":"2018","journal-title":"J Hand Surg Am."},{"key":"R3-20260515","doi-asserted-by":"crossref","first-page":"58","DOI":"10.3113\/FAI.2008.0058","article-title":"A comparison of radiation exposure with the conventional versus mini c arm in orthopedic extremity surgery","volume":"29","author":"Shoaib","year":"2008","journal-title":"Foot Ankle Int"},{"key":"R4-20260515","first-page":"598","article-title":"Reliability of postoperative radiographies in ankle fractures","volume":"8","author":"Abbasian","year":"2020","journal-title":"Arch Bone Joint Surg."},{"key":"R5-20260515","first-page":"34","article-title":"Role of mini C-arm in orthopedic emergency department, Karachi, Pakistan \u201csave time, money and radiation exposure\u201d","volume":"1","author":"Kumar","year":"2017","journal-title":"J Trauma Crit Care"},{"key":"R6-20260515","doi-asserted-by":"crossref","first-page":"102994","DOI":"10.1016\/j.otsr.2021.102994","article-title":"Prospective analysis of intraoperative radiation dose in foot and ankle surgery using mini-c-arm fluoroscopy. continuous series of 1064 procedures","volume":"107","author":"Guyonnet","year":"2021","journal-title":"Orthop Traumatol Surg Res"},{"key":"R7-20260515","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.2106\/JBJS.J.01052","article-title":"Mini-C-arm fluoroscopy for emergency-department reduction of pediatric forearm fractures","volume":"93","author":"Lee","year":"2011","journal-title":"J Bone Joint Surg"},{"key":"R8-20260515","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/S0196-0644(94)70284-5","article-title":"Safety and effectiveness of portable fluoroscopy in the emergency department for the management of distal extremity fractures","volume":"24","author":"Lee","year":"1994","journal-title":"Ann Emerg Med."},{"key":"R9-20260515","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1308\/003588407X155770","article-title":"Effect of introduction of mini C-arm image intensifier in orthopaedic theatre","volume":"89","author":"White","year":"2007","journal-title":"Ann R Coll Surg Engl"},{"key":"R10-20260515","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.fas.2008.10.004","article-title":"Optimizing use of the mini C-arm in foot and ankle surgery","volume":"15","author":"Gangopadhyay","year":"2009","journal-title":"Foot Ankle Surg."},{"key":"R11-20260515","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.fas.2010.01.001","article-title":"A comparative study of radiation dose and screening time between mini C-arm and standard fluoroscopy in elective foot and ankle surgery","volume":"17","author":"Dawe","year":"2011","journal-title":"Foot Ankle Surg"},{"key":"R12-20260515","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/j.jhsa.2014.02.031","article-title":"Ultrasound-assisted closed reduction of distal radius fractures","volume":"39","author":"Kodama","year":"2014","journal-title":"J Hand Surg Am."},{"key":"R13-20260515","doi-asserted-by":"crossref","first-page":"e1097","DOI":"10.3928\/01477447-20160808-01","article-title":"The mini C-arm adds quality and efficiency to the Pediatric Orthopedic Outpatient Clinic","volume":"39","author":"Fanelli","year":"2016","journal-title":"Orthopedics"},{"key":"R14-20260515","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/BPO.0000000000000422","article-title":"Measurement of radiation exposure when using the mini C-Arm to reduce pediatric upper extremity fractures","volume":"36","author":"Sumko","year":"2016","journal-title":"J Pediatr Orthop."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003147","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T13:01:32Z","timestamp":1778850092000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000003147"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":14,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003147","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"value":"0890-5339","type":"print"},{"value":"1531-2291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"2026-01-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}