{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T12:45:51Z","timestamp":1790858751113,"version":"4.1.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>Summary:<\/jats:title>\n                  <jats:p>In nonunion surgery, removing a broken intramedullary nail can be technically challenging and time-consuming, often requiring either creating a bone window or an open approach to retrieve the broken nail. A simple, effective, and minimally traumatic technique is presented for removing the difficult-to-access part of broken canulated intramedullary nails. First, the olive-tipped guidewire is inserted and advanced down the nail until the olive end protrudes out of the broken nail. A minifragment screw is inserted through a locking screw hole in the broken part under fluoroscopy. The guidewire is then gradually retracted until it becomes jammed with the minifragment screw in the locking hole of the nail. The construct is sturdy enough to retrieve the broken nail using the necessary force. Ten cases were retrospectively reviewed, including 4 short cephalomedullary femur nails, 1 long cephalomedullary femur nail, 2 antegrade femur nails, and 3 tibia nails, where this technique was used. All broken nails were successfully extracted in no more than 2 attempts. The average extraction time was 21 minutes (17 minutes for femur nails and 26 minutes for tibia nails). This technique relies solely on existing incisions and bone approaches required for standard nail removal, thus avoiding extra trauma to soft tissues and bone.<\/jats:p>","DOI":"10.1097\/bot.0000000000003179","type":"journal-article","created":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T13:00:28Z","timestamp":1775739628000},"page":"e192-e197","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Extraction of Broken Intramedullary Nails Using Olive-Tipped Guidewire and Minifragment Screws"],"prefix":"10.1097","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9918-3753","authenticated-orcid":false,"given":"Alejandro","family":"Ordas-Bayon","sequence":"first","affiliation":[{"name":"Hospital Universitario Ram\u00f3n y Cajal, Madrid, Spain;"},{"name":"Hospital Ruber Internacional, Madrid, Spain;"},{"name":"Universidad Nebrija, Madrid, Spain; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2172-2849","authenticated-orcid":false,"given":"Matija","family":"Krkovic","sequence":"additional","affiliation":[{"name":"Addenbrooke's Hospital, Cambridge, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260809","doi-asserted-by":"crossref","first-page":"e162775","DOI":"10.1001\/jamasurg.2016.2775","article-title":"Epidemiology of fracture nonunion in 18 human bones","volume":"151","author":"Zura","year":"2016","journal-title":"JAMA Surg"},{"key":"R2-20260809","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1097\/BOT.0000000000000736","article-title":"Debilitating effects of femoral nonunion on health-related quality of life","volume":"31","author":"Brinker","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R3-20260809","doi-asserted-by":"crossref","first-page":"2170","DOI":"10.2106\/JBJS.L.00803","article-title":"The devastating effects of tibial nonunion on health-related quality of life","volume":"95","author":"Brinker","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20260809","doi-asserted-by":"crossref","first-page":"e19","DOI":"10.1097\/BOT.0000000000000417","article-title":"Fate of patients with a \u201cSurprise\u201d positive culture after nonunion surgery","volume":"30","author":"Olszewski","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R5-20260809","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/BOT.0000000000000166","article-title":"Results of a systematic approach to exchange nailing for the treatment of aseptic femoral nonunions","volume":"29","author":"Swanson","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R6-20260809","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/BOT.0000000000000151","article-title":"Results of a systematic approach to exchange nailing for the treatment of aseptic tibial nonunions","volume":"29","author":"Swanson","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R7-20260809","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/0020-1383(92)90121-8","article-title":"Complications of metalwork removal","volume":"23","author":"Sanderson","year":"1992","journal-title":"Injury"},{"key":"R8-20260809","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.tcr.2017.05.011","article-title":"Stuffing the nail: a simple technique for the extraction of a broken femoral nail","volume":"9","author":"Lovell","year":"2017","journal-title":"Trauma Case Rep"},{"key":"R9-20260809","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/00005131-200404000-00011","article-title":"Removal of a broken cannulated tibial nail","volume":"18","author":"Levine","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R10-20260809","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s00402-008-0595-9","article-title":"Removal of broken distal intramedullary nail with a simple method: a case report","volume":"129","author":"Georgilas","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"issue":"suppl 1","key":"R11-20260809","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.jcot.2016.10.009","article-title":"Removal of the broken femoral nail with T-reamer technique: a three-case report","volume":"7","author":"Pongsamakthai","year":"2016","journal-title":"J Clin Orthop Trauma"},{"key":"R12-20260809","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/00005131-200404000-00007","article-title":"Removal of a broken distal closed section intramedullary nail","volume":"18","author":"Steinberg","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R13-20260809","doi-asserted-by":"crossref","first-page":"2498","DOI":"10.1016\/j.injury.2015.07.023","article-title":"Use of a Nancy nail to remove a broken intramedullary nail: a technical note","volume":"46","author":"Kim","year":"2015","journal-title":"Injury"},{"key":"R14-20260809","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1590\/1413-785220182601148079","article-title":"Method for removing broken proximal femoral nails using existing screw hole","volume":"26","author":"Man","year":"2018","journal-title":"Acta Ortop Bras"},{"key":"R15-20260809","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1007\/s00113-012-2158-3","article-title":"Implantatentfernung nach intramedull\u00e4ren Osteosynthesen","volume":"115","author":"Krettek","year":"2012","journal-title":"Unfallchirurg"},{"key":"R16-20260809","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1016\/j.injury.2017.06.010","article-title":"A technique for extraction of the distal segment of a broken femoral nail using a flexible reamer","volume":"48","author":"Zhao","year":"2017","journal-title":"Injury"},{"key":"R17-20260809","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1308\/rcsann.2019.0035","article-title":"A novel technique to remove a broken tibiotalocalcaneal intramedullary nail using moreland hip revision instrumentation","volume":"101","author":"Papachristos","year":"2019","journal-title":"Ann R Coll Surg Engl"},{"key":"R18-20260809","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1016\/j.injury.2020.03.038","article-title":"The ball-less technique: a novel technique for the removal of a broken proximal femoral nail anti-rotation. A technical note","volume":"51","author":"Marise","year":"2020","journal-title":"Injury"},{"key":"R19-20260809","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1590\/S1807-59322010000300007","article-title":"Anterograde removal of broken femoral nails without opening the nonunion site: a new technique","volume":"65","author":"de Amorim Cabrita","year":"2010","journal-title":"Clinics"},{"key":"R20-20260809","doi-asserted-by":"crossref","first-page":"e355","DOI":"10.1097\/OI9.0000000000000355","article-title":"Femoral intramedullary nail extraction using the kissing nail technique when primary measures fail","volume":"8","author":"Brenner","year":"2025","journal-title":"OTA Int"},{"key":"R21-20260809","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.injury.2016.12.014","article-title":"Removal of a broken trigen intertan intertrochanteric antegrade nail","volume":"48","author":"Zheng","year":"2017","journal-title":"Injury"},{"key":"R22-20260809","doi-asserted-by":"crossref","first-page":"362","DOI":"10.5152\/j.aott.2021.20282","article-title":"How to extract a broken cephalomedullary nail safely? A case presentation and review of the literature","volume":"55","author":"Ebrahimpour","year":"2021","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R23-20260809","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/S0020-1383(00)00236-9","article-title":"Removal of the retained fragment of broken solid nails by the intra-medullary route","volume":"32","author":"Giannoudis","year":"2001","journal-title":"Injury"},{"key":"R24-20260809","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.2106\/00004623-198870100-00004","article-title":"Broken intramedullary nails","volume":"70","author":"Franklin","year":"1988","journal-title":"J Bone Joint Surg Am"},{"key":"R25-20260809","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1080\/17453670610013330","article-title":"Removal of a broken nail using a guide wire and a screw","volume":"77","author":"Karladani","year":"2006","journal-title":"Acta Orthop"},{"key":"R26-20260809","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1177\/1938640020950153","article-title":"Complications and radiographic outcomes after tibiotalocalcaneal fusion with a retrograde intramedullary nail","volume":"14","author":"Levinson","year":"2021","journal-title":"Foot Ankle Spec"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0000000000003179","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,9]],"date-time":"2026-08-09T18:00:19Z","timestamp":1786298419000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0000000000003179"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":26,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003179","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"value":"0890-5339","type":"print"},{"value":"1531-2291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]}}}