{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T02:43:37Z","timestamp":1791513817617,"version":"4.3.4"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>To compare anterior minimally invasive plate osteosynthesis (MIPO) using the proximal humerus internal locking system in an upside-down reverse configuration with conventional posterior open reduction and internal fixation (ORIF) using extra-articular locking compression plate for the treatment of extra-articular distal-third humeral shaft fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Prospective randomized controlled trial.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Single Level 1 trauma center (New Delhi, India).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient Selection Criteria:<\/jats:title>\n                    <jats:p>Adult patients aged 18\u201355 years with extra-articular distal-third humeral shaft fractures (AO\/OTA types 12A-C) presenting within 2 weeks of injury were randomized to undergo anterior MIPO or posterior ORIF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcome Measures and Comparisons:<\/jats:title>\n                    <jats:p>Radiological union, functional outcomes (Mayo Elbow Performance Score, University of California-Los Angeles shoulder rating scale), and elbow range-of-motion were assessed and compared at 2 weeks, 6 weeks, 3 months, and 6 months postoperatively. Operative time, intraoperative blood loss, radiation exposure, postoperative pain (visual analog scale scores) and complications were also compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Thirty patients were included (anterior MIPO, n = 14; posterior ORIF, n = 16). The mean age was 27.9 years (range 18\u201355) in the MIPO group and 29.8 years (range 19\u201348) in the ORIF group,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.598. There were 11 men and 3 women in the MIPO group and 11 men and 5 women in the ORIF group,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.68. The mean time to radiological union was shorter in the MIPO group (16.3 \u00b1 1.3 weeks) compared with the ORIF group (18.1 \u00b1 1.2 weeks,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001). Operative time was shorter in the MIPO group (78.9 \u00b1 24.4 minutes vs. 112.6 \u00b1 42.0 minutes,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.013), intraoperative blood loss was lower (182.1 \u00b1 137.4 mL vs. 328.1 \u00b1 96.8 mL,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002), and immediate postoperative pain on day 2 was lower (visual analog scale, 7 \u00b1 0.5 vs. 8 \u00b1 0.6,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Functional outcomes showed no statistically significant differences between groups at 6 months (Mayo Elbow Performance Score: 100 vs. 100\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 1.000; University of California-Los Angeles: 33.8 \u00b1 0.3 vs. 33.7 \u00b1 0.4,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.636), with no statistically significant difference in elbow range-of-motion (137.8 \u00b1 2.5 degrees vs. 135.4 \u00b1 3.0 degrees,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.192). Radiation exposure was higher in the MIPO group (1.5 \u00b1 1.0 mGy vs. 0.3 \u00b1 0.5 mGy,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003). Postoperative radial nerve palsy occurred in one patient in the MIPO group and three in the ORIF group, with complete recovery in all cases. Nonunion occurred in one patient in each group, both of whom required revision surgery.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Anterior MIPO using a reverse proximal humerus internal locking system was associated with shorter time to radiological union, lower intraoperative morbidity, and no statistically significant differences in functional outcomes compared with posterior ORIF for patients with extra-articular distal humerus fractures. It was a viable and effective alternative for managing distal third humeral shaft fractures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000003200","type":"journal-article","created":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T16:01:10Z","timestamp":1777392070000},"page":"482-491","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Comparative Efficacy of Anterior MIPO With PHILOS Versus Posterior ORIF With EA-LCP in Distal-Third Humerus Fractures: A Randomized Controlled Trial"],"prefix":"10.1097","volume":"40","author":[{"given":"Siva S.","family":"Garika","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pashupati","family":"Yadav","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6425-0141","authenticated-orcid":false,"given":"Nitish J.","family":"Jyoti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hemant","family":"Bansal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samarth","family":"Mittal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivek","family":"Trikha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijay","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260814","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1097\/00005131-200301000-00006","article-title":"Adult distal humeral metaphyseal fractures: epidemiology and results of treatment","volume":"17","author":"Robinson","year":"2003","journal-title":"J Orthop Trauma."},{"key":"R2-20260814","doi-asserted-by":"crossref","first-page":"128","DOI":"10.5397\/cise.2015.18.3.128","article-title":"PHILOS plate osteosynthesis in metaphyseal fractures of the distal humerus through an anterolateral approach","volume":"18","author":"Park","year":"2015","journal-title":"Clin Shoulder Elbow."},{"key":"R3-20260814","doi-asserted-by":"crossref","first-page":"686","DOI":"10.2106\/JBJS.J.00845","article-title":"Distal humeral fractures in adults","volume":"93","author":"Nauth","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R4-20260814","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/0020-1383(95)93494-3","article-title":"The mechanisms of elbow fractures: an investigation using impact tests in vitro","volume":"26","author":"Amis","year":"1995","journal-title":"Injury"},{"key":"R5-20260814","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1302\/0301-620X.72B2.2312570","article-title":"Functional bracing for comminuted extra-articular fractures of the distal third of the humerus","volume":"72","author":"Sarmiento","year":"1990","journal-title":"J Bone Joint Surg Br."},{"key":"R6-20260814","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1007\/s00402-002-0403-x","article-title":"Functional treatment of the distal third humeral shaft fractures","volume":"122","author":"Pehlivan","year":"2002","journal-title":"Arch Orthop Trauma Surg."},{"key":"R7-20260814","doi-asserted-by":"crossref","first-page":"2343","DOI":"10.2106\/00004623-200611000-00004","article-title":"Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation","volume":"88","author":"Jawa","year":"2006","journal-title":"J Bone Joint Surg Am."},{"key":"R8-20260814","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1007\/s00590-020-02708-0","article-title":"Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures","volume":"30","author":"Jitprapaikulsarn","year":"2020","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R9-20260814","doi-asserted-by":"crossref","first-page":"2309499017727948","DOI":"10.1177\/2309499017727948","article-title":"Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: a retrospective study","volume":"25","author":"Trikha","year":"2017","journal-title":"J Orthop Surg."},{"key":"R10-20260814","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1007\/s00264-013-2213-x","article-title":"Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate","volume":"38","author":"Capo","year":"2014","journal-title":"Int Orthop."},{"key":"R11-20260814","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.1016\/j.injury.2009.05.004","article-title":"Functional bracing of humeral shaft fractures. A review of clinical studies","volume":"41","author":"Papasoulis","year":"2010","journal-title":"Injury"},{"key":"R12-20260814","first-page":"795","article-title":"Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study","volume":"66","author":"Tejwani","year":"2009","journal-title":"J Trauma."},{"key":"R13-20260814","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1016\/j.injury.2014.08.036","article-title":"Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants","volume":"45","author":"Scolaro","year":"2014","journal-title":"Injury"},{"key":"R14-20260814","first-page":"1","article-title":"Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach","volume":"12","author":"Kharbanda","year":"2017","journal-title":"Strategies Trauma Limb Reconstr."},{"key":"R15-20260814","doi-asserted-by":"crossref","first-page":"2119","DOI":"10.1007\/s00264-022-05435-9","article-title":"Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures","volume":"46","author":"Shin","year":"2022","journal-title":"Int Orthop."},{"key":"R16-20260814","doi-asserted-by":"crossref","first-page":"1938","DOI":"10.1016\/j.injury.2020.05.022","article-title":"Analyzing the modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures with some concerns","volume":"51","author":"Bansal","year":"2020","journal-title":"Injury"},{"key":"R17-20260814","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/BOT.0b013e31815928c2","article-title":"Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures","volume":"21","author":"Zhiquan","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R18-20260814","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/BF00440575","article-title":"Significance of postoperative stability for bony reparation of comminuted fractures - an experimental study","volume":"109","author":"Heitemeyer","year":"1990","journal-title":"Arch Orthop Trauma Surg."},{"key":"R19-20260814","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1016\/j.injury.2019.05.030","article-title":"Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures","volume":"50","author":"Sohn","year":"2019","journal-title":"Injury"},{"key":"R20-20260814","doi-asserted-by":"crossref","first-page":"e26271","DOI":"10.5812\/traumamon.26271v2","article-title":"Treatment of humeral shaft fractures: minimally invasive plate osteosynthesis versus open reduction and internal fixation","volume":"20","author":"Esmailiejah","year":"2015","journal-title":"Trauma Mon."},{"key":"R21-20260814","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/j.otsr.2011.03.024","article-title":"Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery?","volume":"97","author":"Roux","year":"2011","journal-title":"Orthop Traumatol Surg Res."},{"key":"R22-20260814","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/BOT.0000000000000232","article-title":"A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures","volume":"29","author":"Kim","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R23-20260814","doi-asserted-by":"crossref","first-page":"479","DOI":"10.2106\/00004623-199274040-00003","article-title":"Semiconstrained arthroplasty for the treatment of rheumatoid arthritis of the elbow","volume":"74","author":"Morrey","year":"1992","journal-title":"J Bone Joint Surg Am."},{"key":"R24-20260814","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/S0749-8063(05)80374-3","article-title":"Arthroscopic treatment of full-thickness rotator cuff tears: 2- to 7-year follow-up study","volume":"9","author":"Ellman","year":"1993","journal-title":"Arthroscopy"},{"key":"R25-20260814","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s00264-009-0753-x","article-title":"Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique","volume":"34","author":"An","year":"2010","journal-title":"Int Orthop."},{"key":"R26-20260814","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.otsr.2011.09.016","article-title":"Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating","volume":"98","author":"Oh","year":"2012","journal-title":"Orthop Traumatol Surg Res."},{"key":"R27-20260814","doi-asserted-by":"crossref","first-page":"215","DOI":"10.3109\/13645706.2016.1151891","article-title":"Open vs. closed reduction combined with minimally invasive plate osteosynthesis in humeral fractures","volume":"25","author":"Liu","year":"2016","journal-title":"Minim Invasive Ther Allied Technol."},{"key":"R28-20260814","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1159\/000095487","article-title":"Percutaneous fixation of comminuted fractures of the humerus: initial experience at Al Razi Hospital, Kuwait","volume":"15","author":"Pospula","year":"2006","journal-title":"Med Princ Pract."},{"key":"R29-20260814","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1007\/s00264-008-0522-2","article-title":"Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach","volume":"33","author":"Ji","year":"2009","journal-title":"Int Orthop."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0000000000003200","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T13:00:38Z","timestamp":1786712438000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0000000000003200"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":29,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003200","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"value":"0890-5339","type":"print"},{"value":"1531-2291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"2026-04-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}