{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T11:08:25Z","timestamp":1789729705184,"version":"4.0.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Summary:<\/jats:title>\n                  <jats:p>When treating periprosthetic femur fractures, bicortical screw fixation around a medullary-filling femoral stem may present a technical challenge, potentially leading surgeons to opt for unicortical locking screws or cerclage wires. These solutions may not achieve desirable stability, particularly in osteoporotic bone. In this technical note, we describe a simple approach using bicortical small-fragment screws-in-washers through large-fragment plates to facilitate secure bicortical screw passage around the stem. We also present preliminary outcomes from a case series in which this technique was used.<\/jats:p>","DOI":"10.1097\/bot.0000000000003223","type":"journal-article","created":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T18:02:30Z","timestamp":1778004150000},"page":"e238-e242","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Periprosthetic Femur Fractures: The Screw-In-Washer Technique for Bicortical Small-Fragment Screw Fixation Through Large-Fragment Plates. A Technical Trick and Case Series"],"prefix":"10.1097","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5869-133X","authenticated-orcid":false,"given":"Ahmed Nageeb","family":"Mahmoud","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Geisinger Medical Center, Danville, PA; and"},{"name":"Department of Orthopedic Surgery, Ain Shams University Faculty of Medicine, Cairo, Egypt."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel S.","family":"Horwitz","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Geisinger Medical Center, Danville, PA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260918","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.arth.2021.09.006","article-title":"Mortality after postoperative periprosthetic fracture of the femur after hip arthroplasty in the last decade: meta-analysis of 35 cohort studies including 4841 patients","volume":"37","author":"Lamb","year":"2022","journal-title":"J Arthroplasty"},{"key":"R2-20260918","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1007\/s00198-023-06695-w","article-title":"Periprosthetic fractures: an unrecognized osteoporosis crisis","volume":"34","author":"Binkley","year":"2023","journal-title":"Osteoporos Int"},{"key":"R3-20260918","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/BOT.0000000000002695","article-title":"Dual plate fixation of periprosthetic distal femur fractures","volume":"38","author":"Andring","year":"2024","journal-title":"J Orthop Trauma"},{"key":"R4-20260918","doi-asserted-by":"crossref","first-page":"e246","DOI":"10.1097\/OI9.0000000000000246","article-title":"Periprosthetic fracture management of the proximal femur","volume":"6","author":"Padilla-Rojas","year":"2023","journal-title":"OTA Int"},{"key":"R5-20260918","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/s00590-023-03665-0","article-title":"Adequate bone healing after supplementary fixation of periprosthetic total knee arthroplasty fractures using Luque cerclage wiring: a retrospective case series","volume":"34","author":"Mahmoud","year":"2024","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R6-20260918","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/BOT.0000000000002730","article-title":"Retrograde intramedullary nailing versus locked plating for extreme distal periprosthetic femur fractures: a multicenter retrospective cohort study","volume":"38","author":"Van Rysselberghe","year":"2024","journal-title":"J Orthop Trauma"},{"key":"R7-20260918","doi-asserted-by":"crossref","first-page":"2333","DOI":"10.1016\/j.arth.2015.06.060","article-title":"Better axial stiffness of a bicortical screw construct compared to a cable construct for comminuted Vancouver B1 proximal femoral fractures","volume":"30","author":"Griffiths","year":"2015","journal-title":"J Arthroplasty"},{"key":"R8-20260918","doi-asserted-by":"crossref","first-page":"1","DOI":"10.58616\/001c.88826","article-title":"The biomechanical performance of different plate fixation configurations to repair Vancouver type C periprosthetic femur fractures","volume":"1","author":"Kheir","year":"2023","journal-title":"SurgiColl"},{"key":"R9-20260918","doi-asserted-by":"crossref","first-page":"e138","DOI":"10.1097\/OI9.0000000000000138","article-title":"A systematic review of the use of titanium versus stainless steel implants for fracture fixation","volume":"4","author":"Barber","year":"2021","journal-title":"OTA Int"},{"key":"R10-20260918","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1115\/1.3138497","article-title":"Three-dimensional finite element analysis of a simplified compression plate fixation system","volume":"106","author":"Cheal","year":"1984","journal-title":"J Biomech Eng"},{"key":"R12-20260918","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1097\/00005131-199604000-00009","article-title":"The strength of plate fixation in relation to the number and spacing of bone screws","volume":"10","author":"T\u00f6rnkvist","year":"1996","journal-title":"J Orthop Trauma"},{"key":"R13-20260918","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","article-title":"Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases","volume":"28","author":"Ricci","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R14-20260918","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1177\/1938640011422597","article-title":"Combining dissimilar metals in orthopaedic implants: revisited","volume":"4","author":"Zartman","year":"2011","journal-title":"Foot Ankle Specialist"},{"key":"R15-20260918","doi-asserted-by":"crossref","first-page":"e1175","DOI":"10.3928\/01477447-20130821-21","article-title":"Mixing implants of differing metallic composition in the treatment of upper-extremity fractures","volume":"36","author":"Acevedo","year":"2013","journal-title":"Orthopedics"},{"key":"R16-20260918","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.spinee.2003.12.004","article-title":"Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?","volume":"4","author":"Serhan","year":"2004","journal-title":"Spine J"},{"key":"R17-20260918","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1007\/s00402-003-0614-9","article-title":"Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates","volume":"124","author":"Krischak","year":"2004","journal-title":"Arch Orthop Trauma Surg"},{"key":"R18-20260918","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.injury.2007.07.015","article-title":"Should the galvanic combination of titanium and stainless steel surgical implants be avoided?","volume":"39","author":"Hol","year":"2008","journal-title":"Injury"},{"key":"R19-20260918","doi-asserted-by":"crossref","first-page":"2591","DOI":"10.1016\/j.arth.2021.02.060","article-title":"Retrospective population-based cohort study of incidence, complications, and survival of 202 operatively treated periprosthetic femoral fractures","volume":"36","author":"Miettinen","year":"2021","journal-title":"J Arthroplasty"},{"key":"R20-20260918","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.1016\/j.arth.2016.12.007","article-title":"Comparable results with porous metal augments in combination with either cemented or uncemented cups in revision hip arthroplasty: an analysis of one hundred forty-seven revisions at a mean of five years","volume":"32","author":"Mahmoud","year":"2017","journal-title":"J Arthroplasty"},{"issue":"suppl 1 Pt 2","key":"R22-20260918","doi-asserted-by":"crossref","first-page":"275","DOI":"10.2106\/00004623-200609001-00011","article-title":"Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. Surgical technique","volume":"88","author":"Ricci","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R23-20260918","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1177\/112070001002000106","article-title":"Uncemented revision hip arthroplasty in B2 and B3 periprosthetic femoral fractures\u2014a prospective analysis","volume":"20","author":"Rayan","year":"2010","journal-title":"Hip Int"},{"key":"R24-20260918","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1177\/2151458512462870","article-title":"A review of periprosthetic femoral fractures associated with total hip arthroplasty","volume":"3","author":"Marsland","year":"2012","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"R25-20260918","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.3390\/jcm11051371","article-title":"Peri-and interprosthetic femoral fractures\u2014current concepts and new developments for internal fixation","volume":"11","author":"K\u00f6sters","year":"2022","journal-title":"J Clin Med"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0000000000003223","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T11:00:13Z","timestamp":1789729213000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0000000000003223"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":23,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000003223","relation":{},"ISSN":["0890-5339","1531-2291"],"issn-type":[{"value":"0890-5339","type":"print"},{"value":"1531-2291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"2026-04-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}