{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T12:31:13Z","timestamp":1792499473559,"version":"4.5.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,5]]},"DOI":"10.1097\/bot.0b013e318059b993","type":"journal-article","created":{"date-parts":[[2007,5,3]],"date-time":"2007-05-03T13:03:40Z","timestamp":1178197420000},"page":"316-322","source":"Crossref","is-referenced-by-count":544,"title":["Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-Plate"],"prefix":"10.1097","volume":"21","author":[{"given":"Rohit","family":"Arora","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Lutz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfred","family":"Hennerbichler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dietmar","family":"Krappinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Espen","family":"MD","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Gabl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-5-20210212","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/j.jhsa.2005.02.009","article-title":"Palmar plating system for Colles fractures-a preliminary report.","volume":"30","author":"Kamano","year":"2005","journal-title":"J Hand Surg Am"},{"key":"R2-5-20210212","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.jhsa.2005.10.016","article-title":"Treatment of distal radius fractures with a low profile dorsal plating system: an outcomes assessment.","volume":"31","author":"Simic","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R3-5-20210212","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0266-7681(03)00011-1","article-title":"Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate-a biomechanical study in a cadaveric model.","volume":"28","author":"Leung","year":"2003","journal-title":"J Hand Surg Br"},{"key":"R4-5-20210212","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.jhsa.2005.12.017","article-title":"Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model.","volume":"31","author":"Taylor","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R5-5-20210212","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.jhsa.2005.04.017","article-title":"Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study.","volume":"30","author":"Trease","year":"2005","journal-title":"J Hand Surg Am"},{"issue":"Suppl 2","key":"R6-5-20210212","doi-asserted-by":"crossref","first-page":"S80","DOI":"10.1007\/s00198-004-1808-x","article-title":"Treatment of osteoporotic distal radius fractures.","volume":"16","author":"Ring","year":"2005","journal-title":"Osteoporos Int"},{"key":"R7-5-20210212","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1007\/s00113-006-1163-9","article-title":"What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly?","volume":"109","author":"Voigt","year":"2006","journal-title":"Unfallchirurg"},{"key":"R8-5-20210212","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1055\/s-2006-924042","article-title":"Open reduction and internal fixation of distal radius extension fractures in women over 60 years of age with the dorsal radius plate (pi-plate).","volume":"38","author":"Keller","year":"2006","journal-title":"Handchir Mikrochir Plast Chir"},{"key":"R9-5-20210212","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1016\/j.jhsa.2006.05.008","article-title":"Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study.","volume":"31","author":"Kamath","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R10-5-20210212","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1007\/s00064-005-1155-x","article-title":"Dorsal double-plate fixation of the distal radius.","volume":"17","author":"Rikli","year":"2005","journal-title":"Oper Orthop Traumatol"},{"issue":"Suppl 1","key":"R11-5-20210212","first-page":"195","article-title":"Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius.","volume":"87","author":"Ring","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"R12-5-20210212","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jhsa.2005.09.011","article-title":"Volar versus dorsal plating in the management of intra-articular distal radius fractures.","volume":"31","author":"Ruch","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R13-5-20210212","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/S0363-5023(98)80063-4","article-title":"Complications of the AO\/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report.","volume":"23","author":"Kambouroglou","year":"1998","journal-title":"J Hand Surg Am"},{"key":"R14-5-20210212","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1053\/jhsu.1999.1279","article-title":"Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius.","volume":"24","author":"Nunley","year":"1999","journal-title":"J Hand Surg Am"},{"key":"R15-5-20210212","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00264-002-0393-x","article-title":"Osteosynthesis of distal radial fractures with a volar locking screw plate system.","volume":"27","author":"Drobetz","year":"2003","journal-title":"Int Orthop"},{"key":"R16-5-20210212","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius.","volume":"31","author":"Rozental","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R17-5-20210212","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/0363-5023(94)90028-0","article-title":"Factors affecting functional outcome of displaced intra-articular distal radius fractures.","volume":"19","author":"Trumble","year":"1994","journal-title":"J Hand Surg Am"},{"key":"R18-5-20210212","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0363-5023(78)80089-6","article-title":"Open reduction of carpal dislocations: indications and operative techniques.","volume":"3","author":"Green","year":"1978","journal-title":"J Hand Surg Am"},{"key":"R19-5-20210212","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/S0894-1130(96)80076-7","article-title":"Development of a scale for patient rating of wrist pain and disability.","volume":"9","author":"MacDermid","year":"1996","journal-title":"J Hand Ther"},{"key":"R20-5-20210212","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1053\/jhsu.2001.22917","article-title":"Surgical management of delayed union and nonunion of distal radius fractures.","volume":"26","author":"Fernandez","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R21-5-20210212","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.hcl.2005.02.003","article-title":"Volar plate fixation of distal radius fractures.","volume":"21","author":"Orbay","year":"2005","journal-title":"Hand Clin"},{"key":"R22-5-20210212","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1016\/j.jhsa.2006.07.004","article-title":"The outcome of intra-articular distal radius fractures treated with fragment-specific fixation.","volume":"31","author":"Benson","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R23-5-20210212","first-page":"558","article-title":"Fractures of the distal end of the radius treated by internal fixation and early function.","volume":"78","author":"Rikli","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"R24-5-20210212","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/J.JHSB.2005.09.021","article-title":"Peripheral nerve compression neuropathy after fractures of the distal radius.","volume":"31","author":"Bienek","year":"2006","journal-title":"J Hand Surg Br"},{"key":"R25-5-20210212","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1142\/S0218810400000223","article-title":"The treatment of unstable distal radius fractures with volar fixation.","volume":"5","author":"Orbay","year":"2000","journal-title":"Hand Surg"},{"key":"R26-5-20210212","doi-asserted-by":"crossref","first-page":"59","DOI":"10.3109\/17453679709003977","article-title":"Open reduction and internal fixation of displaced intraarticular fractures of the distal radius. 31 patients followed for 3-7 years.","volume":"68","author":"Hove","year":"1997","journal-title":"Acta Orthop Scand"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0b013e318059b993","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:36:31Z","timestamp":1786034191000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00005131-200705000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,5]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2007]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0b013e318059b993","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2007,5]]}}}