{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:07:58Z","timestamp":1786118878807,"version":"build-2736575974"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,8]]},"DOI":"10.1097\/bot.0b013e318126bb8e","type":"journal-article","created":{"date-parts":[[2007,8,1]],"date-time":"2007-08-01T03:01:21Z","timestamp":1185937281000},"page":"435-441","source":"Crossref","is-referenced-by-count":42,"title":["Sacroiliac Joint Compression Using an Anterior Pelvic Compressor: A Mechanical Study in Synthetic Bone"],"prefix":"10.1097","volume":"21","author":[{"given":"Michael J","family":"Gardner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Kendoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven","family":"Ostermeier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Musa","family":"Citak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"H\u00fcfner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Krettek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean E","family":"Nork","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-2-20210212","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.injury.2004.03.003","article-title":"Damage control orthopaedics in unstable pelvic ring injuries.","volume":"35","author":"Giannoudis","year":"2004","journal-title":"Injury"},{"key":"R4-2-20210212","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1016\/S0039-6109(16)44584-6","article-title":"Hemorrhage in major pelvic fractures.","volume":"68","author":"Mucha","year":"1988","journal-title":"Surg Clin North Am"},{"key":"R5-2-20210212","first-page":"862","article-title":"A protocol for the initial management of unstable pelvic fractures.","volume":"64","author":"Bassam","year":"1998","journal-title":"Am Surg"},{"key":"R6-2-20210212","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1097\/00005373-199803000-00006","article-title":"Pressure-volume characteristics of the intact and disrupted pelvic retroperitoneum.","volume":"44","author":"Grimm","year":"1998","journal-title":"J Trauma"},{"issue":"Suppl 2","key":"R7-2-20210212","doi-asserted-by":"crossref","first-page":"B19","DOI":"10.1016\/S0020-1383(99)90004-9","article-title":"Unstable pelvic ring disruptions in unstable patients.","volume":"30","author":"Kregor","year":"1999","journal-title":"Injury"},{"key":"R8-2-20210212","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/00003086-199408000-00010","article-title":"The Hannover experience in management of pelvic fractures.","volume":"305","author":"Pohlemann","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"R9-2-20210212","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1097\/00003086-198904000-00009","article-title":"The role of external fixation in pelvic disruptions.","volume":"241","author":"Kellam","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"R10-2-20210212","doi-asserted-by":"crossref","first-page":"278","DOI":"10.3109\/17453677809005765","article-title":"Fixation of pelvic fractures and dislocations. An experimental study on the loading of pelvic fractures and sacro-iliac dislocations after external compression fixation.","volume":"49","author":"Gunterberg","year":"1978","journal-title":"Acta Orthop Scand"},{"key":"R11-2-20210212","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/0020-1383(75)90061-3","article-title":"External fixation of the pelvic girdle with a trapezoid compression frame.","volume":"7","author":"Slatis","year":"1975","journal-title":"Injury"},{"key":"R12-2-20210212","first-page":"73","article-title":"External fixation of unstable pelvic fractures: experiences in 22 patients treated with a trapezoid compression frame.","volume":"151","author":"Slatis","year":"1980","journal-title":"Clin Orthop Relat Res"},{"key":"R14-2-20210212","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1097\/00005131-200009000-00003","article-title":"Distraction external fixation in lateral compression pelvic fractures.","volume":"14","author":"Bellabarba","year":"2000","journal-title":"J Orthop Trauma"},{"key":"R15-2-20210212","first-page":"273","article-title":"Placement of half-pins for supra-acetabular external fixation: an anatomic study.","volume":"269-","author":"Haidukewych","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"R16-2-20210212","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/00003086-199904000-00030","article-title":"Effect of pin location on stability of pelvic external fixation.","volume":"361","author":"Kim","year":"1999","journal-title":"Clin Orthop Relat Res"},{"key":"R17-2-20210212","first-page":"296","article-title":"[A simple supraacetabular external fixation for pelvic ring fractures].","volume":"17","author":"Gansslen","year":"2005","journal-title":"Oper Orthop Traumatol"},{"key":"R18-2-20210212","first-page":"148","article-title":"Supra-acetabular placement of external fixator pins: a safe and expedient method of providing the injured pelvis with stability.","volume":"34","author":"Poelstra","year":"2005","journal-title":"Am J Orthop"},{"key":"R19-2-20210212","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1097\/BOT.0b013e318030e3e4","article-title":"Stablization of unstable pelvic fractures with supraacetabular compression external fixation.","volume":"21","author":"Gardner","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R20-2-20210212","first-page":"363","article-title":"[Stabilizing the pelvic ring with the external fixator. Biomechanical studies and clinical experiences].","volume":"21","author":"Egbers","year":"1992","journal-title":"Orthopade"},{"key":"R21-2-20210212","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/00003086-199106000-00009","article-title":"The antishock pelvic clamp.","volume":"267","author":"Ganz","year":"1991","journal-title":"Clin Orthop Relat Res"},{"key":"R22-2-20210212","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/00005131-200402000-00008","article-title":"Pelvic emergency clamps: anatomic landmarks for a safe primary application.","volume":"18","author":"Pohlemann","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R23-2-20210212","first-page":"254","article-title":"Analysis of the torque applied to bone screws by trauma surgeons. Comparisons based on years of experience and material of implant construction.","volume":"24","author":"McGuire","year":"1995","journal-title":"Am J Orthop"},{"key":"R24-2-20210212","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1097\/00005131-200308000-00002","article-title":"Biomechanical comparison of posterior pelvic ring fixation.","volume":"17","author":"Yinger","year":"2003","journal-title":"J Orthop Trauma"},{"key":"R25-2-20210212","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.medengphy.2005.07.022","article-title":"Measuring contact area, force, and pressure for bioengineering applications: using Fuji Film and TekScan systems.","volume":"28","author":"Bachus","year":"2006","journal-title":"Med Eng Phys"},{"key":"R26-2-20210212","first-page":"525","article-title":"Dynamic in vitro measurement of posterior cruciate ligament load and tibiofemoral stress after TKA in dependence on tibiofemoral slope. Clin Biomech (Bristol, Avon).","volume":"21","author":"Ostermeier","year":"2006","journal-title":""},{"key":"R27-2-20210212","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1007\/s10439-006-9200-y","article-title":"Experimental measurement of tibiofemoral contact area in a meniscectomized ovine model using a resistive pressure measuring sensor.","volume":"34","author":"von Lewinski","year":"2006","journal-title":"Ann Biomed Eng"},{"key":"R28-2-20210212","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1097\/00005373-198807000-00011","article-title":"Pelvic fracture classification: correlation with hemorrhage.","volume":"28","author":"Cryer","year":"1988","journal-title":"J Trauma"},{"key":"R29-2-20210212","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1097\/00005373-198611000-00005","article-title":"Hemorrhage associated with major pelvic fracture: a multispecialty challenge.","volume":"26","author":"Moreno","year":"1986","journal-title":"J Trauma"},{"key":"R30-2-20210212","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1080\/110241500750009078","article-title":"Crush injuries of the pelvis.","volume":"166","author":"Tscherne","year":"2000","journal-title":"Eur J Surg"},{"key":"R31-2-20210212","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1001\/archsurg.1989.01410040032006","article-title":"Pelvic fracture hemorrhage. Priorities in management.","volume":"124","author":"Evers","year":"1989","journal-title":"Arch Surg"},{"key":"R33-2-20210212","first-page":"393","article-title":"[Pelvic clamps for controlling shock in posterior pelvic ring injuries. Application, biomechanical aspects and initial clinical results].","volume":"21","author":"Witschger","year":"1992","journal-title":"Orthopade"},{"key":"R34-2-20210212","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1302\/0301-620X.81B6.0810955","article-title":"Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients.","volume":"81","author":"Lindahl","year":"1999","journal-title":"J Bone Joint Surg Br"},{"key":"R35-2-20210212","first-page":"65","article-title":"Modern concepts of external skeletal fixation of the pelvis.","volume":"151","author":"Mears","year":"1980","journal-title":"Clin Orthop Relat Res"},{"key":"R36-2-20210212","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/BF02442527","article-title":"External fixation of unstable pelvic ring fractures: comparative rigidity of some current frame configurations.","volume":"20","author":"Brown","year":"1982","journal-title":"Med Biol Eng Comput"},{"key":"R37-2-20210212","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1097\/00005131-199306000-00005","article-title":"Posterior pelvic fixation using a transiliac 4.5-mm reconstruction plate: a clinical and biomechanical study.","volume":"7","author":"Albert","year":"1993","journal-title":"J Orthop Trauma"},{"key":"R38-2-20210212","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/00005131-198802010-00008","article-title":"Comparative study of the Orthofix and Pittsburgh frames for external fixation of unstable pelvic ring fractures.","volume":"2","author":"Bell","year":"1988","journal-title":"J Orthop Trauma"},{"key":"R39-2-20210212","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1097\/00005131-199611000-00001","article-title":"Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures.","volume":"10","author":"Comstock","year":"1996","journal-title":"J Orthop Trauma"},{"key":"R40-2-20210212","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1097\/00005373-198410000-00002","article-title":"A study of external skeletal fixation systems for unstable pelvic fractures.","volume":"24","author":"Dahners","year":"1984","journal-title":"J Trauma"},{"key":"R41-2-20210212","first-page":"245","article-title":"Biomechanical simulation of the anteroposterior compression injury of the pelvis. An understanding of instability and fixation.","volume":"309","author":"Simonian","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"R42-2-20210212","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/00005131-199412000-00005","article-title":"Box plate fixation of the symphysis pubis: biomechanical evaluation of a new technique.","volume":"8","author":"Simonian","year":"1994","journal-title":"J Orthop Trauma"},{"key":"R43-2-20210212","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1097\/00005131-199412000-00004","article-title":"Internal fixation of the unstable anterior pelvic ring: a biomechanical comparison of standard plating techniques and the retrograde medullary superior pubic ramus screw.","volume":"8","author":"Simonian","year":"1994","journal-title":"J Orthop Trauma"},{"key":"R44-2-20210212","first-page":"245","article-title":"Anterior versus posterior provisional fixation in the unstable pelvis. A biomechanical comparison.","volume":"310","author":"Simonian","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"R45-2-20210212","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/0020-1383(95)92180-I","article-title":"Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring.","volume":"26","author":"Varga","year":"1995","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BOT.0b013e318126bb8e","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:49:26Z","timestamp":1786034966000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00005131-200708000-00002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,8]]},"references-count":41,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2007]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0b013e318126bb8e","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2007,8]]}}}