{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T13:01:03Z","timestamp":1780491663668,"version":"3.54.1"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,2]]},"DOI":"10.1097\/bot.0b013e3182a225fa","type":"journal-article","created":{"date-parts":[[2013,7,16]],"date-time":"2013-07-16T11:21:59Z","timestamp":1373973719000},"page":"70-76","source":"Crossref","is-referenced-by-count":36,"title":["Osteosynthesis of Unstable Intracapsular Femoral Neck Fracture by Dynamic Locking Plate or Screw Fixation"],"prefix":"10.1097","volume":"28","author":[{"given":"Ran","family":"Thein","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Herman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paz","family":"Kedem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aharon","family":"Chechik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nachshon","family":"Shazar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-2-20210212","first-page":"2254","article-title":"Treatment of femoral neck fractures in young adults.","volume":"90","author":"Ly","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R2-2-20210212","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/00005131-199805000-00002","article-title":"Predictors of early failure of fixation in the treatment of displaced subcapital hip fractures.","volume":"12","author":"Chua","year":"1998","journal-title":"J Orthop Trauma"},{"key":"R3-2-20210212","doi-asserted-by":"crossref","first-page":"129","DOI":"10.2106\/00004623-199401000-00019","article-title":"Intracapsular fractures of the hip.","volume":"76","author":"Swiontkowski","year":"1994","journal-title":"J Bone Joint Surg Am"},{"key":"R4-2-20210212","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.2106\/00004623-198567080-00018","article-title":"Femoral neck fractures in skeletally mature patients, fifty years old or less.","volume":"67","author":"Tooke","year":"1985","journal-title":"J Bone Joint Surg Am"},{"key":"R5-2-20210212","doi-asserted-by":"crossref","first-page":"69","DOI":"10.3109\/17453678909150097","article-title":". Early loss of fixation of femoral neck fractures. Comparison of three devices in 244 cases.","volume":"60","author":"Husby","year":"1989","journal-title":"Acta Orthop Scand"},{"key":"R6-2-20210212","doi-asserted-by":"crossref","first-page":"15","DOI":"10.2106\/00004623-199401000-00003","article-title":". Outcomes after displaced fractures of the femoral neck. A meta-analysis of one hundred and six published reports.","volume":"76","author":"Lu-yao","year":"1994","journal-title":"J Bone Joint Surg Am"},{"key":"R7-2-20210212","doi-asserted-by":"crossref","first-page":"619","DOI":"10.2106\/JBJS.H.01750","article-title":". Internal screw fixation compared with bipolar hemiarthroplasty for treatment of displaced femoral neck fractures in elderly patients.","volume":"92","author":"Gjertsen","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R8-2-20210212","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.injury.2009.09.004","article-title":"Internal fixation of intracapsular hip fractures with a dynamic locking plate: initial experience and results for 83 patients treated with a new implant.","volume":"41","author":"Parker","year":"2010","journal-title":"Injury"},{"key":"R9-2-20210212","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1302\/0301-620X.84B8.0841150","article-title":". Hemiarthroplasty versus internal fixation for displaced intracapsular hip fractures in the elderly. A randomised trial of 455 patients.","volume":"84","author":"Parker","year":"2002","journal-title":"J Bone Joint Surg Br"},{"key":"R10-2-20210212","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1302\/0301-620X.87B5.15237","article-title":"The complications of displaced intracapsular fractures of the hip.","volume":"87","author":"Gurusamy","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"R12-2-20210212","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.2106\/00004623-200408000-00015","article-title":". Operative treatment of femoral neck fractures in patients between the ages of fifteen and fifty years.","volume":"86-A","author":"Haidukewych","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R13-2-20210212","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1097\/00005131-199805000-00003","article-title":". Unstable femoral neck fractures in young adults: treatment with the AO 130-degree blade plate.","volume":"12","author":"Broos","year":"1998","journal-title":"J Orthop Trauma"},{"key":"R14-2-20210212","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/00003086-200206000-00009","article-title":"Reduction and fixation of displaced intracapsular fractures of the proximal femur.","volume":"399","author":"Bosch","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"R15-2-20210212","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1302\/0301-620X.93B6.26432","article-title":". Fixation of intracapsular fractures of the femoral neck in young patients: risk factors for failure.","volume":"93","author":"Duckworth","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"R16-2-20210212","first-page":"1166","article-title":". Internal fixation versus hemiarthroplasty for displaced fractures of the femoral neck in elderly patients with severe cognitive impairment. J Bone Joint Surg Br. 2005;87:523-529.","volume":"87","author":"Blomfeldt","year":"2005","journal-title":"Erratum in: J Bone Joint Surg Br"},{"key":"R17-2-20210212","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1302\/0301-620X.86B7.15047","article-title":". Delayed internal fixation of fractures of the neck of the femur in young adults. A prospective, randomised study comparing closed and open reduction.","volume":"86","author":"Upadhyay","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"R19-2-20210212","first-page":"131","article-title":"Complications after intracapsular hip fractures in young adults. A meta-analysis of 18 published studies involving 564 fractures.","volume":"36","author":"Damany","year":"2005","journal-title":"Injury"},{"key":"R20-2-20210212","doi-asserted-by":"crossref","first-page":"873","DOI":"10.3928\/01477447-20101021-15","article-title":". Displaced femoral neck fractures in young adults treated with closed reduction and internal fixation.","volume":"33","author":"Huang","year":"2010","journal-title":"Orthopedics"},{"key":"R21-2-20210212","doi-asserted-by":"crossref","first-page":"249","DOI":"10.2106\/00004623-200602000-00001","article-title":". Randomized comparison of reduction and fixation, bipolar hemiarthroplasty, and total hip arthroplasty. Treatment of displaced intracapsular hip fractures in healthy older patients.","volume":"88","author":"Keating","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R22-2-20210212","doi-asserted-by":"crossref","first-page":"e170","DOI":"10.1097\/BOT.0b013e31823b4cd1","article-title":". Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant.","volume":"26","author":"Berkes","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R24-2-20210212","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.2106\/00004623-200209000-00013","article-title":". Comparison of early and delayed fixation of subcapital hip fractures in patients sixty years of age or less.","volume":"84-A","author":"Jain","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"R25-2-20210212","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1097\/00003086-199910000-00037","article-title":". Vertical shear fractures of femoral neck. A biomechanical study.","volume":"367","author":"Baitner","year":"1999","journal-title":"Clin Orthop Relat Res"},{"key":"R26-2-20210212","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1097\/BOT.0b013e31814b822e","article-title":". Vertical oriented femoral neck fractures: mechanical analysis of four fixation techniques.","volume":"21","author":"Aminian","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R27-2-20210212","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","article-title":". Results of internal fixation of Pauwels type-3 vertical femoral neck fractures.","volume":"90","author":"Liporace","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R28-2-20210212","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1016\/j.injury.2008.11.003","article-title":"Avascular necrosis after internal fixation of intracapsular hip fractures; a study of the outcome for 1023 patients.","volume":"40","author":"Loizou","year":"2009","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0b013e3182a225fa","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T05:26:44Z","timestamp":1646112404000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201402000-00002"}},"subtitle":["Early Results"],"short-title":[],"issued":{"date-parts":[[2014,2]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0b013e3182a225fa","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2014,2]]}}}