{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T19:55:46Z","timestamp":1783108546268,"version":"3.54.6"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:p>Femoral neck fracture (FNF) is not common in osteogenesis imperfecta patients but may result in serious complications if not properly treated in due time. We present three types of FNF in osteogenesis imperfecta and their characteristics, treatment methods and outcomes. Cases of FNF followed for more than 2\u2009years were selected from the osteogenesis imperfecta database. Medical records and radiographs were reviewed to obtain demographic information and to determine ambulatory status, mode of injury, location of the fracture line, presence of preexisting implants, treatment methods and complications. Outcomes were evaluated according to the radiographic results and ambulatory function. The study investigated 15 FNFs in 10 patients including 1 Sillence type I, 1 type III and 8 type IV. They were either community or household ambulators. The mean age at fracture was 11.7\u2009years. The fractures were followed for an average of 6.3\u2009years. Six fractures were attributed to accidental injuries and nine without noticeable trauma. The fracture pattern was categorized into undisplaced (<jats:italic toggle=\"yes\">n<\/jats:italic>\u2009=\u20093), angulated-stable (<jats:italic toggle=\"yes\">n\u2009=\u2009<\/jats:italic>7) or displaced-unstable (<jats:italic toggle=\"yes\">n\u2009=\u2009<\/jats:italic>5) types. Five fractures were fixed in-situ using screws or Kirschner wires. Other five fractures were treated by closed reduction and screw fixation and the remaining five fractures were managed by femoral valgus osteotomy. Bony union was achieved, and prefracture ambulatory status was restored in all cases. A high index of suspicion is required in the diagnosis of undisplaced or angulated-stable fractures. Treatment is usually challenging, but a judicious approach considering the fracture pattern and patient characteristics result in successful outcomes. The angulated-stable pattern of fracture is unique in osteogenesis imperfecta patients and requires special attention.<\/jats:p>","DOI":"10.1097\/bpb.0000000000000887","type":"journal-article","created":{"date-parts":[[2021,6,3]],"date-time":"2021-06-03T07:05:34Z","timestamp":1622703934000},"page":"e114-e121","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Patterns of femoral neck fracture and its treatment methods in patients with osteogenesis imperfecta"],"prefix":"10.1097","volume":"31","author":[{"given":"Wan Kee","family":"Hong","sequence":"first","affiliation":[{"name":"Division of Pediatric Orthopaedics, Seoul National University Children\u2019s Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doo Jae","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Seoul National University Children\u2019s Hospital, Seoul"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"HoeJoeng","family":"Chung","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Wonju Severance Christian Hospital, Wonju College of Medicine Yonsei University, Wonju"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaemoon","family":"Lim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Jeju National University Hospital, Jeju"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang Ho","family":"Shin","sequence":"additional","affiliation":[{"name":"Division of Pediatric Orthopaedics, Seoul National University Children\u2019s Hospital"},{"name":"Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won Joon","family":"Yoo","sequence":"additional","affiliation":[{"name":"Division of Pediatric Orthopaedics, Seoul National University Children\u2019s Hospital"},{"name":"Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tae-Joon","family":"Cho","sequence":"additional","affiliation":[{"name":"Division of Pediatric Orthopaedics, Seoul National University Children\u2019s Hospital"},{"name":"Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,5,28]]},"reference":[{"key":"R1-20250526","doi-asserted-by":"crossref","first-page":"417","DOI":"10.4055\/cios20060","article-title":"Management of osteogenesis imperfecta: a multidisciplinary comprehensive approach.","volume":"12","author":"Cho","year":"2020","journal-title":"Clin Orthop Surg"},{"key":"R2-20250526","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.injury.2008.07.028","article-title":"Intramedullary osteosynthesis for fracture associated with osteogenesis imperfecta.","volume":"40","author":"Wolf","year":"2009","journal-title":"Injury"},{"key":"R3-20250526","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s11832-013-0495-6","article-title":"Management pitfalls of fractured neck of femur in osteogenesis imperfecta.","volume":"7","author":"Chow","year":"2013","journal-title":"J Child Orthop"},{"key":"R4-20250526","first-page":"1168","article-title":"A case of screw fixation of femur neck fracture with the use of computer navigation in a woman with osteogenesis imperfecta.","volume":"65","author":"Foo","year":"2008","journal-title":"J Trauma"},{"key":"R5-20250526","doi-asserted-by":"crossref","first-page":"14","DOI":"10.5430\/css.v3n3p14","article-title":"Femoral neck fractures in osteogenesis imperfecta patients: a retrospective case series and novel surgical technique.","volume":"3","author":"Gorsche","year":"2017","journal-title":"Case Stud Surg"},{"key":"R6-20250526","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1302\/1863-2548.11.160212","article-title":"Femoral neck fractures in osteogenesis imperfecta treated with bisphosphonates.","volume":"11","author":"Papanna","year":"2017","journal-title":"J Child Orthop"},{"key":"R7-20250526","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1097\/BPB.0b013e328347a345","article-title":"Cannulated screw fixation of fracture neck of femur in children with osteogenesis imperfecta.","volume":"20","author":"Tsang","year":"2011","journal-title":"J Pediatr Orthop B"},{"key":"R8-20250526","doi-asserted-by":"crossref","first-page":"e0449","DOI":"10.2106\/JBJS.CC.18.00449","article-title":"Treatment of femur neck fracture in children with osteogenesis imperfecta: two case reports.","volume":"9","author":"Morcos","year":"2019","journal-title":"JBJS Case Connect"},{"key":"R9-20250526","first-page":"83","article-title":"Pathologic femoral neck fractures in children.","volume":"38","author":"Shrader","year":"2009","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"R10-20250526","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1097\/BPO.0b013e31818e19b7","article-title":"Results and complications of a surgical technique for correction of coxa vara in children with osteopenic bones.","volume":"28","author":"Fassier","year":"2008","journal-title":"J Pediatr Orthop"},{"key":"R11-20250526","first-page":"43","article-title":"Wagner multiple K-wire osteosynthesis to correct coxa vara in the young child: experience with a versatile \u2018tailor-made\u2019 high angle blade plate equivalent.","volume":"10","author":"Widmann","year":"2001","journal-title":"J Pediatr Orthop B"},{"key":"R12-20250526","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1097\/00003086-199309000-00028","article-title":"Long-term results of valgus osteotomy for congenital coxa vara.","author":"Desai","year":"1993","journal-title":"Clin Orthop Relat Res"},{"key":"R13-20250526","doi-asserted-by":"crossref","first-page":"733","DOI":"10.2106\/JBJS.N.01185","article-title":"Locking plate placement with unicortical screw fixation adjunctive to intramedullary rodding in long bones of patients with osteogenesis imperfecta.","volume":"97","author":"Cho","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"R14-20250526","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1007\/s007760050108","article-title":"Insufficiency fracture of the femoral neck after intramedullary nailing.","volume":"4","author":"Kitajima","year":"1999","journal-title":"J Orthop Sci"},{"key":"R15-20250526","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/BPO.0000000000000343","article-title":"Acetabular protrusio and proximal femur fractures in patients with osteogenesis imperfecta.","volume":"35","author":"Trehan","year":"2015","journal-title":"J Pediatr Orthop"},{"key":"R16-20250526","doi-asserted-by":"crossref","first-page":"e285","DOI":"10.1097\/BPO.0000000000001739","article-title":"Pseudo-protrusio acetabular deformity in osteogenesis imperfecta patients.","volume":"41","author":"Song","year":"2021","journal-title":"J Pediatr Orthop"},{"key":"R17-20250526","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/01.bpo.0000189007.55174.7c","article-title":"High prevalence of coxa vara in patients with severe osteogenesis imperfecta.","volume":"26","author":"Aarabi","year":"2006","journal-title":"J Pediatr Orthop"},{"key":"R18-20250526","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5371\/hp.2018.30.1.53","article-title":"Pauwels osteotomy for femoral neck nonunion in two adult siblings with osteogenesis imperfecta.","volume":"30","author":"Kloen","year":"2018","journal-title":"Hip Pelvis"},{"key":"R19-20250526","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1097\/BTO.0000000000000228","article-title":"Step-cut valgus osteotomy of proximal femur.","volume":"32","author":"Effendi","year":"2017","journal-title":"Tech Orthop"}],"container-title":["Journal of Pediatric Orthopaedics B"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000000887","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T22:06:35Z","timestamp":1748297195000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000000887"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,28]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bpb.0000000000000887","relation":{},"ISSN":["1060-152X"],"issn-type":[{"value":"1060-152X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5,28]]}}}