{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T22:40:03Z","timestamp":1748299203519,"version":"3.41.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:p>The purpose of this study was to examine whether measurement accuracy is impacted with a low radiation radiograph technique. Treatment decisions for hip dysplasia require serial radiographs to monitor acetabular anatomy. However, radiation use creates concern for future malignancy. Standard radiograph technique utilizes a grid to enhance clarity, but requires a larger X-ray dose. We hypothesized grid removal would lower radiation exposure without decreasing measurement accuracy. This is a retrospective cohort study of patients with idiopathic DDH and neuromuscular hip displacement at a single institution from 2019 to 2020 receiving surveillance radiographs. A cohort receiving modified technique radiographs (grid removed) was compared to an age-matched cohort receiving standard technique radiographs. Four examiners measured radiographs on two separate occasions, a minimum of 2 weeks apart. Migration percentage (MP) was measured for neuromuscular patients and acetabular index (AI) for idiopathic DDH. Intraclass correlation coefficient (ICC) with a 95% confidence interval (CI) was used to evaluate inter-observer and intra-observer agreement for measurements. Average radiation dose for both techniques. A total of 134 age-matched patients were included for measurement of MP. Thirty age-matched patients were included for AI measurements. Inter and intra-rater reliability of MP and AI were not different with or without use of the grid. There was a 50\u201375% decrease in radiation dose per radiograph following grid removal, dependent on patient size. The adjusted radiograph technique showed no significant difference in MP or AI reliability. A slight decrease in picture contrast did not jeopardize measurement reliability and decreased radiation exposure for the patient significantly. This simple technique can be useful for patients requiring multiple radiographs over time.<\/jats:p>","DOI":"10.1097\/bpb.0000000000000967","type":"journal-article","created":{"date-parts":[[2022,3,8]],"date-time":"2022-03-08T12:48:14Z","timestamp":1646743694000},"page":"539-545","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Reliability of radiographic measurements for hip dysplasia using a reduced radiation technique"],"prefix":"10.1097","volume":"31","author":[{"given":"Cheryl R.","family":"Lawing","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, University of South Florida, Tampa, Florida"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rebecca L.","family":"Gorbe","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of South Florida, Tampa, Florida"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maureen J.","family":"Maciel","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of South Florida, Tampa, Florida"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Travis C.","family":"Greene","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of South Florida, Tampa, Florida"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph G.","family":"Khoury","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of South Florida, Tampa, Florida"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,3,7]]},"reference":[{"key":"R1-20250526","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1302\/0301-620X.86B6.14441","article-title":"Acetabular dysplasia after treatment for developmental dysplasia of the hip. Implications for secondary procedures.","volume":"86","author":"Albinana","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"R2-20250526","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00003086-198612000-00004","article-title":"Etiology of osteoarthritis of the hip.","volume":"213","author":"Harris","year":"1986","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20250526","doi-asserted-by":"crossref","first-page":"S33","DOI":"10.1097\/BPO.0000000000001347","article-title":"Natural history of spastic hip disease.","volume":"39","author":"Lins","year":"2019","journal-title":"J Pediatr Orthop"},{"key":"R4-20250526","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/s11832-011-0356-0","article-title":"Dysplasia of the hip in adolescent patients successfully treated for developmental dysplasia of the hip.","volume":"5","author":"Modaressi","year":"2011","journal-title":"J Child Orthop"},{"key":"R5-20250526","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1302\/0301-620X.88B11.18114","article-title":"A systematic review of the evidence for hip surveillance in children with cerebral palsy.","volume":"88","author":"Gordon","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"R6-20250526","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1093\/jnci\/djn045","article-title":"Solid cancer incidence in atomic bomb survivors exposed in utero or as young children.","volume":"100","author":"Preston","year":"2008","journal-title":"J Natl Cancer Inst"},{"key":"R7-20250526","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","article-title":"Estimated risks of radiation-induced fatal cancer from pediatric CT.","volume":"176","author":"Brenner","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"R8-20250526","doi-asserted-by":"crossref","first-page":"f2360","DOI":"10.1136\/bmj.f2360","article-title":"Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians.","volume":"346","author":"Mathews","year":"2013","journal-title":"BMJ"},{"key":"R9-20250526","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1097\/01241398-200003000-00023","article-title":"The risk of carcinogenesis from radiographs to pediatric orthopaedic patients.","volume":"20","author":"Bone","year":"2000","journal-title":"J Pediatr Orthop"},{"issue":"Suppl 2","key":"R10-20250526","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s00247-006-0191-5","article-title":"Cancer risks following diagnostic and therapeutic radiation exposure in children.","volume":"36","author":"Kleinerman","year":"2006","journal-title":"Pediatr Radiol"},{"key":"R11-20250526","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1118\/1.596496","article-title":"Studies of performance of antiscatter grids in digital radiography: effect on signal-to-noise ratio.","volume":"17","author":"Chan","year":"1990","journal-title":"Med Phys"},{"key":"R15-20250526","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s11832-012-0406-2","article-title":"Reliability of plain radiographic parameters for developmental dysplasia of the hip in children.","volume":"6","author":"Upasani","year":"2012","journal-title":"J Child Orthop"},{"key":"R16-20250526","first-page":"39","article-title":"Normal values of the hip joint for the evaluation of X-rays in children and adults.","volume":"119","author":"Tonnis","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"R17-20250526","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BPO.0000000000000791","article-title":"Normal percentile reference curves and correlation of acetabular index and acetabular depth ratio in children.","volume":"38","author":"Novais","year":"2018","journal-title":"J Pediatr Orthop"},{"key":"R19-20250526","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1259\/bjr.72.856.10474491","article-title":"Reliability of radiological measurements in the assessment of hip dysplasia in adults.","volume":"72","author":"Nelitz","year":"1999","journal-title":"Br J Radiol"},{"key":"R20-20250526","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/ort.1980.51.suppl-184.01","article-title":"The stability of the hip in children. A radiological study of the results of muscle surgery in cerebral palsy.","volume":"184","author":"Reimers","year":"1980","journal-title":"Acta Orthop Scand Suppl"},{"key":"R21-20250526","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1302\/0301-620X.86B3.14094","article-title":"Inter- and intra-measurer error in the measurement of Reimers\u2019 hip migration percentage.","volume":"86","author":"Faraj","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"R22-20250526","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1097\/01241398-200209000-00017","article-title":"Hip displacement in spastic cerebral palsy: repeatability of radiologic measurement.","volume":"22","author":"Parrott","year":"2002","journal-title":"J Pediatr Orthop"},{"key":"R23-20250526","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/BPO.0000000000000227","article-title":"Reliability of radiologic measures of hip displacement in a cohort of preschool-aged children with cerebral palsy.","volume":"34","author":"Craven","year":"2014","journal-title":"J Pediatr Orthop"},{"key":"R26-20250526","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1007\/s10554-017-1067-5","article-title":"Selective anti-scatter grid removal during coronary angiography and PCI: a simple and safe technique for radiation reduction.","volume":"33","author":"Roy","year":"2017","journal-title":"Int J Cardiovasc Imaging"},{"key":"R27-20250526","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1088\/1361-6498\/aa80a4","article-title":"Removal of scatter radiation in paediatric cardiac catheterisation: a randomised controlled clinical trial.","volume":"37","author":"Gould","year":"2017","journal-title":"J Radiol Prot"},{"key":"R28-20250526","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1007\/s00247-013-2824-9","article-title":"Guidelines for anti-scatter grid use in pediatric digital radiography.","volume":"44","author":"Fritz","year":"2014","journal-title":"Pediatr Radiol"}],"container-title":["Journal of Pediatric Orthopaedics B"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000000967","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T22:02:18Z","timestamp":1748296938000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000000967"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,7]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bpb.0000000000000967","relation":{},"ISSN":["1060-152X"],"issn-type":[{"type":"print","value":"1060-152X"}],"subject":[],"published":{"date-parts":[[2022,3,7]]}}}