{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,5]],"date-time":"2025-08-05T13:02:41Z","timestamp":1754398961346,"version":"3.41.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,3]]},"abstract":"<jats:p>The migration of epiphyseal screws into growing physis in tension band plating is a known complication. We investigated the screw migration into physis in 10 patients (18 plates) to study the various technical details, which may have contributed to this complication. The methodology involved retrospective review of radiological records. Among these 10 affected patients, in four patients, there were eight additional tension band plates, which had remained uncomplicated (\u2018controls\u2019) at the time when implant failure was detected. We statistically compared the length of epiphyseal screw, proximity of screw start point to the physis, screw trajectory angle, interscrew angle and correction rate between the migrated and other uncomplicated plates. Majority patients were postrachitic (<jats:italic toggle=\"yes\">n<\/jats:italic> = 7). The mean time from primary procedure to detection of radiological complication was 15.1 months. The mean epiphyseal screw length proportion in migrated and uncomplicated plates matched. The starting point of epiphyseal screw was relatively closer to physis in migrated plates. The trajectory of epiphyseal screw with respect to physis was more divergent in the migrated plates (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.02). All implants were inserted in a divergent manner with mean interscrew angle being 22.3\u00b0 for migrated and 13.8\u00b0 for the uncomplicated plates (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.02). The correction rate of the implant reduced as it failed. Osteopenic bone and pathological physis predispose to migrated plates. Technically, a wider trajectory of epiphyseal screw and too divergent screws should be avoided. A migrated implant becomes less effective in its function.<\/jats:p>","DOI":"10.1097\/bpb.0000000000001030","type":"journal-article","created":{"date-parts":[[2022,11,29]],"date-time":"2022-11-29T16:07:33Z","timestamp":1669738053000},"page":"165-169","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Predisposing factors for migration of epiphyseal screws into physis in tension band plating"],"prefix":"10.1097","volume":"32","author":[{"given":"Ankit","family":"Jain","sequence":"first","affiliation":[{"name":"Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anil","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ravi","family":"Jethwa","sequence":"additional","affiliation":[{"name":"Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jatin Raj","family":"Sareen","sequence":"additional","affiliation":[{"name":"Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yogesh","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,11,14]]},"reference":[{"key":"R1-20250526","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1302\/0301-620X.92B2.22937","article-title":"Correcting genu varum and genu valgum in children by guided growth: temporary hemiepiphysiodesis using tension band plates.","volume":"92","author":"Ballal","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"R2-20250526","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/BPB.0b013e32834f0477","article-title":"Distal tibial physeal bridge: a complication from a tension band plate and screw construct. Report of a case.","volume":"22","author":"Oda","year":"2013","journal-title":"J Pediatr Orthop B"},{"key":"R3-20250526","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1007\/s00264-011-1369-5","article-title":"The 8-plate versus physeal stapling for temporary hemiepiphyseodesis correcting genu valgum and genu varum: a retrospective analysis of thirty five patients.","volume":"36","author":"Jelinek","year":"2012","journal-title":"Int Orthop"},{"key":"R4-20250526","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1097\/BPO.0000000000000115","article-title":"The efficacy and complications of 2-hole 3.5\u2009mm reconstruction plates and 4\u2009mm noncanulated cancellous screws for temporary hemiepiphysiodesis around the knee.","volume":"34","author":"Aslani","year":"2014","journal-title":"J Pediatr Orthop"},{"key":"R5-20250526","doi-asserted-by":"crossref","first-page":"e4951","DOI":"10.1097\/MD.0000000000004951","article-title":"Guided growth for tibia vara (Blount\u2019s disease).","volume":"95","author":"Heflin","year":"2016","journal-title":"Medicine (Baltim)"},{"key":"R6-20250526","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1097\/BPB.0000000000000397","article-title":"Paediatric lower limb deformity correction with the eight plate: adverse events and correction outcomes of 126 patients from an international multicentre study.","volume":"26","author":"Joeris","year":"2017","journal-title":"J Pediatr Orthop B"},{"key":"R7-20250526","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1097\/BPB.0000000000000367","article-title":"Failure of tension band plating: a case series.","volume":"26","author":"Masquijo","year":"2017","journal-title":"J Pediatr Orthop B"},{"key":"R8-20250526","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.2106\/JBJS.RVW.16.00115","article-title":"Guided growth: current perspectives and future challenges.","volume":"5","author":"Yang","year":"2017","journal-title":"JBJS Rev"},{"key":"R9-20250526","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1302\/2058-5241.6.200098","article-title":"Growth modulation with tension-band plates for the correction of paediatric lower limb angular deformity: current concepts and indications for a rational use.","volume":"6","author":"Masquijo","year":"2021","journal-title":"EFORT Open Rev"},{"key":"R10-20250526","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1302\/0301-620X.100B8.BJJ-2017-1206.R3","article-title":"Eight-plate epiphysiodesis: are we creating an intra-articular deformity?","volume":"100","author":"Sinha","year":"2018","journal-title":"Bone Joint J"},{"key":"R11-20250526","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1302\/1863-2548.13.180086","article-title":"Hemiepiphysiodesis using tension band plates: does the initial screw angle influence the rate of correction?","volume":"13","author":"Eltayeby","year":"2019","journal-title":"J Child Orthop"},{"key":"R12-20250526","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.jocd.2005.11.001","article-title":"Changes in bone mineral density following treatment of osteomalacia.","volume":"9","author":"Bhambri","year":"2006","journal-title":"J Clin Densitom"}],"container-title":["Journal of Pediatric Orthopaedics B"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000001030","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T22:03:15Z","timestamp":1748296995000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000001030"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,14]]},"references-count":12,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bpb.0000000000001030","relation":{},"ISSN":["1060-152X"],"issn-type":[{"type":"print","value":"1060-152X"}],"subject":[],"published":{"date-parts":[[2022,11,14]]}}}