{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T01:20:16Z","timestamp":1781313616717,"version":"3.54.1"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:p>Guided growth affects the physis in children to produce a desired effect. Several devices achieve alteration of growth, including staples, plates, and screws. Complications can include device failures, failure to modulate growth as expected, and unintended physeal arrest. We present the results of a unique technique designed to minimize these complications. This was a retrospective review of guided growth at the knee at a single institution utilizing cannulated screws with epiphyseal-entry points. Each case was reviewed to determine the presence of complications related to guided growth, including implant breakage, implant pull-out or pull-through, iatrogenic physeal arrest, failure to modulate growth, and the incidence of revision surgeries. There were 89 patients who had 146 epiphyseal-entry guided growth procedures with a total of 221 4.5\u2005mm cannulated screws. There were no iatrogenic physeal arrests. Five (2.26%) screws in 4 (4.49%) patients had either a broken screw or screw pull-out\/pull-through requiring revision procedures. Three patients had osteotomies after skeletal maturity. Four had revision-guided growth for other reasons: 2 due to a lack of timely follow-up, 1 for iatrogenic genu varum without implant failure, and 1 due to recurrent deformity after implant removal. Revision procedures were unanticipated in 6 (6.74%) patients. This study describes a technique for placing cannulated screws at the knee with epiphyseal starting points. Our rate of complications and number of revision surgeries compare favorably with those noted for other techniques. Guided growth using epiphyseal-entry cannulated screws is a safe, effective option for most patients.<\/jats:p>","DOI":"10.1097\/bpb.0000000000001118","type":"journal-article","created":{"date-parts":[[2023,8,23]],"date-time":"2023-08-23T12:01:28Z","timestamp":1692792088000},"page":"114-118","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Epiphyseal-entry cannulated screws for temporary guided growth of the knees: a retrospective review of 89 cases"],"prefix":"10.1097","volume":"33","author":[{"given":"Kevin M.","family":"Neal","sequence":"first","affiliation":[{"name":"Nemours Children\u2019s Specialty Care, Jacksonville, Florida, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary M.","family":"Kiebzak","sequence":"additional","affiliation":[{"name":"Nemours Children\u2019s Specialty Care, Jacksonville, Florida, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,8,15]]},"reference":[{"key":"R1-20250526","first-page":"1","article-title":"Operative arrestment of longitudinal growth of bones in the treatment of deformities.","volume":"15","author":"Phemister","year":"1933","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20250526","first-page":"170","article-title":"Percutaneous epiphysiodesis.","author":"Bowen","year":"1984","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20250526","doi-asserted-by":"crossref","first-page":"320","DOI":"10.2106\/00004623-197961030-00001","article-title":"Epiphyseal stapling for angular deformity at the knee.","volume":"61","author":"Zuege","year":"1979","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20250526","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1097\/BPO.0b013e31803433a1","article-title":"Guided growth for angular correction: a preliminary series using a tension band plate.","volume":"27","author":"Stevens","year":"2007","journal-title":"J Pediatr Orthop"},{"key":"R5-20250526","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/01241398-199805000-00018","article-title":"Percutaneous epiphysiodesis using transphyseal screws (PETS).","volume":"18","author":"M\u00e9taizeau","year":"1998","journal-title":"J Pediatr Orthop"},{"key":"R6-20250526","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1097\/BPO.0b013e3181841fda","article-title":"Guided growth for pathological physes: radiographic improvement during realignment.","volume":"28","author":"Stevens","year":"2008","journal-title":"J Pediatr Orthop"},{"key":"R7-20250526","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1302\/0301-620X.94B2.27470","article-title":"Efficacy and late complications of percutaneous epiphysiodesis with transphyseal screws.","volume":"94","author":"Ilharreborde","year":"2012","journal-title":"J Bone Joint Surg Br"},{"key":"R8-20250526","doi-asserted-by":"crossref","first-page":"626","DOI":"10.3109\/17453674.2014.960646","article-title":"Temporary epiphyseodesis for limb-length discrepancy. 8- to 15-year follow-up of 34 children.","volume":"85","author":"Siedhoff","year":"2014","journal-title":"Acta Orthop"},{"key":"R9-20250526","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1097\/BPO.0000000000000214","article-title":"Percutaneous epiphysiodesis using transphyseal screws in the management of leg length discrepancy: optimal operation timing and techniques to avoid complications.","volume":"35","author":"Song","year":"2015","journal-title":"J Pediatr Orthop"},{"key":"R10-20250526","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1097\/BPO.0000000000000647","article-title":"Comparing percutaneous physeal epiphysiodesis and eight-plate epiphysiodesis for the treatment of limb length discrepancy.","volume":"37","author":"Bayhan","year":"2017","journal-title":"J Pediatr Orthop"},{"key":"R11-20250526","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/01241398-199105000-00013","article-title":"Prospective evaluation of fifty-three consecutive percutaneous epiphysiodeses of the distal femur and proximal tibia and fibula.","volume":"11","author":"Timperlake","year":"1991","journal-title":"J Pediatr Orthop"},{"key":"R12-20250526","first-page":"172","article-title":"L\u2019\u00e9piphysiod\u00e8se percutan\u00e9e. Analyse d\u2019une s\u00e9rie de 60 patients \u00e0 maturit\u00e9 [Percutaneous epiphysiodesis. Analysis of a series of 60 full-grown patients].","volume":"84","author":"Craviari","year":"1998","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"R13-20250526","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1097\/BPO.0b013e3181832475","article-title":"Efficacy and safety of percutaneous epiphysiodesis.","volume":"28","author":"Inan","year":"2008","journal-title":"J Pediatr Orthop"},{"key":"R14-20250526","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/BPB.0b013e3282e61af7","article-title":"The correction of leg-length discrepancy after treatment in developmental dysplasia of the hip by using a percutaneous epiphysiodesis.","volume":"17","author":"Inan","year":"2008","journal-title":"J Pediatr Orthop B"},{"key":"R15-20250526","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/BPB.0b013e32836132f0","article-title":"Guided growth for the treatment of limb length discrepancy: a comparative study of the three most commonly used surgical techniques.","volume":"22","author":"Lykissas","year":"2013","journal-title":"J Pediatr Orthop B"},{"key":"R16-20250526","doi-asserted-by":"crossref","first-page":"e575","DOI":"10.3928\/01477447-20130426-18","article-title":"Guided growth for the treatment of moderate leg-length discrepancy.","volume":"36","author":"Pendleton","year":"2013","journal-title":"Orthopedics"},{"key":"R17-20250526","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1097\/BPO.0b013e3182a11d23","article-title":"Dual 8-plate technique is not as effective as ablation for epiphysiodesis about the knee.","volume":"33","author":"Stewart","year":"2013","journal-title":"J Pediatr Orthop"},{"key":"R18-20250526","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11751-013-0180-9","article-title":"Epiphysiodesis for limb length discrepancy: a comparison of two methods.","volume":"9","author":"Babu","year":"2014","journal-title":"Strategies Trauma Limb Reconstr"},{"key":"R19-20250526","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1302\/1863-2548.12.170050","article-title":"Guided growth: preliminary results of a multinational study of 967 physes in 537 patients.","volume":"12","author":"Danino","year":"2018","journal-title":"J Child Orthop"},{"key":"R20-20250526","doi-asserted-by":"crossref","first-page":"e533","DOI":"10.1097\/BPO.0000000000001835","article-title":"Efficacy of percutaneous retrograde transphyseal guided growth screw in distal femoral angular deformity correction: a new technique.","volume":"41","author":"Abdelaziz","year":"2021","journal-title":"J Pediatr Orthop"},{"key":"R21-20250526","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1097\/BPO.0000000000000116","article-title":"Medial malleolar screw versus tension-band plate hemiepiphysiodesis for ankle valgus in the skeletally immature.","volume":"34","author":"Driscoll","year":"2014","journal-title":"J Pediatr Orthop"},{"key":"R22-20250526","first-page":"414","article-title":"Medial malleolar screw hemiepiphysiodesis for ankle valgus in children with spina bifida.","volume":"80","author":"Bayhan","year":"2014","journal-title":"Acta Orthop Belg"},{"key":"R23-20250526","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1097\/BPO.0000000000000333","article-title":"Rate of correction and recurrence of ankle valgus in children using a transphyseal medial malleolar screw.","volume":"35","author":"Chang","year":"2015","journal-title":"J Pediatr Orthop"},{"key":"R24-20250526","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s11832-015-0687-3","article-title":"Percutaneous epiphysiodesis using transphyseal screws for limb-length discrepancies: high variability among growth predictor models.","volume":"9","author":"Monier","year":"2015","journal-title":"J Child Orthop"}],"container-title":["Journal of Pediatric Orthopaedics B"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000001118","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T22:02:11Z","timestamp":1748296931000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BPB.0000000000001118"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,15]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/bpb.0000000000001118","relation":{},"ISSN":["1060-152X"],"issn-type":[{"value":"1060-152X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,8,15]]}}}