{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T22:03:12Z","timestamp":1709330592867},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"14","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7,15]]},"abstract":"<jats:sec>\n            <jats:title>Study Design.<\/jats:title>\n            <jats:p>Cadaveric.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective.<\/jats:title>\n            <jats:p>Determine optimal fluoroscopic views for detecting cervical lateral mass screw (LMS) violations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data.<\/jats:title>\n            <jats:p>Single plane intraoperative x-rays are commonly used but frequently inadequate due to its complex trajectory. Fluoroscopy can be taken in multiple planes, but the ideal fluoroscopic view to assess malposition is not known: depending on the view, any given screw may look \u201cin\u201d or \u201cout.\u201d<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods.<\/jats:title>\n            <jats:p>C3\u20136 LMS were inserted in three cadavers. To evaluate neuroforaminal violation, LMS were inserted into the foramen with the tip penetrating the anterior cortex by 0, 2, and 4\u200amm. To assess facet joint violation, LMS were inserted toward the subjacent facet joint with the tip penetrating the anterior cortex by 0 and 2\u200amm. Fluoroscopic views were taken 0\u00b0, 10\u00b0, 20\u00b0, 30\u00b0, and 40\u00b0 to the lateral plane. Views were independently evaluated by three blinded spine surgeons.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results.<\/jats:title>\n            <jats:p>Twenty-degree oblique view correctly identified a 2\u200amm penetration into the neuroforamen in 79%, and a 4\u200amm penetration in 86%, for a sensitivity of 83% and specificity of 90%. Thirty-degree view had lower sensitivity (76%) but slightly higher specificity (93%). Twenty-degree and 30\u00b0 views were significantly more sensitive than the other views. Zero-degree view correctly identified a 2\u200amm penetration into the facet joint in 93%, for a sensitivity of 93% and specificity of 92%. Ten-degree view had lower sensitivity (72%) but higher specificity (100%). The 0\u00b0 view was significantly more sensitive than the other views.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion.<\/jats:title>\n            <jats:p>Twenty-degree and 30\u00b0 oblique views significantly provided the most sensitive assessment of LMS potentially violating the neuroforamen, whereas the 0\u00b0 neutral lateral view significantly provided the most sensitive assessment of facet violations. The specificities were also high (in the 90% range) for these views. We recommend the use of these views intraoperatively when assessing proper placement of LMS fluoroscopically.<\/jats:p>\n            <jats:p>\n                                 <jats:bold>Level of Evidence:<\/jats:bold> N\/A<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/brs.0000000000001985","type":"journal-article","created":{"date-parts":[[2016,12,3]],"date-time":"2016-12-03T16:54:51Z","timestamp":1480784091000},"page":"1039-1043","source":"Crossref","is-referenced-by-count":0,"title":["Is It \u201cIn\u201d or \u201cOut\u201d? The Optimal Fluoroscopic Views for Intraoperative Determination of Proper Lateral Mass Screw Placement"],"prefix":"10.1097","volume":"42","author":[{"given":"Sang Bum","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Konyang University Hospital, Daejeon, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John M.","family":"Rhee","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Emory Spine Center, Atlanta, GA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byung Hak","family":"Oh","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Konyang University Hospital, Daejeon, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"You Gun","family":"Won","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Konyang University Hospital, Daejeon, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yousun","family":"Jung","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Konyang University Hospital, Daejeon, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kun Young","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Daejeon Veterans Hospital, Daejeon, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William C.","family":"Hutton","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Emory Spine Center, Atlanta, GA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chulmin","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Mathematics, University of West Georgia, Carrollton, GA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20240205","doi-asserted-by":"crossref","first-page":"2136","DOI":"10.2106\/JBJS.L.01522","article-title":"Lateral mass screw fixation in the cervical spine: a systematic literature review","volume":"95","author":"Coe","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20240205","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1007\/s00402-012-1507-6","article-title":"Cervical lateral mass screw fixation without fluoroscopic control: analysis of risk factors for complications associated with screw insertion","volume":"132","author":"Inoue","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"R3-20240205","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1097\/BSD.0b013e3182024c06","article-title":"Lateral mass screw complications: analysis of 1662 screws","volume":"24","author":"Katonis","year":"2011","journal-title":"J Spinal Disord Tech"},{"key":"R4-20240205","doi-asserted-by":"crossref","first-page":"2442","DOI":"10.1097\/00007632-199511001-00013","article-title":"Complications of posterior cervical plating","volume":"20","author":"Heller","year":"1995","journal-title":"Spine"},{"key":"R5-20240205","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.spinee.2005.04.010","article-title":"Lateral mass screw fixation for cervical spine trauma: associated complications and efficacy in maintaining alignment","volume":"6","author":"Pateder","year":"2006","journal-title":"Spine J"},{"key":"R6-20240205","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.spinee.2007.04.002","article-title":"Accuracy of pedicle and mass screw placement in the spine without using fluoroscopy: a prospective clinical study","volume":"8","author":"Kotil","year":"2008","journal-title":"Spine J"},{"key":"R7-20240205","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1186\/1475-925X-13-115","article-title":"Four lateral mass screw fixation techniques in lower cervical spine following laminectomy: a finite element analysis study of stress distribution","volume":"13","author":"Song","year":"2014","journal-title":"Biomed Eng Online"},{"key":"R8-20240205","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1097\/01.bsd.0000166640.23448.09","article-title":"Posterior cervical lateral mass screw fixation: analysis of 1026 consecutive screws in 143 patients","volume":"18","author":"Sekhon","year":"2005","journal-title":"J Spinal Disord Tech"},{"key":"R9-20240205","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/foc.2004.16.1.11","article-title":"History of instrumentation for stabilization of the subaxial cervical spine","volume":"16","author":"Omeis","year":"2004","journal-title":"Neurosurg Focus"},{"key":"R10-20240205","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1016\/j.spinee.2014.03.046","article-title":"Radiographic and clinical assessment of a freehand lateral mass screw fixation technique: is it always safe in subaxial cervical spine?","volume":"14","author":"Ra","year":"2014","journal-title":"Spine J"},{"key":"R11-20240205","doi-asserted-by":"crossref","first-page":"2057","DOI":"10.1097\/00007632-199910010-00016","article-title":"The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques","volume":"24","author":"Xu","year":"1999","journal-title":"Spine"},{"key":"R12-20240205","doi-asserted-by":"crossref","first-page":"E45","DOI":"10.1097\/BSD.0000000000000143","article-title":"The effect of hubbing on the pull-out strength of lateral mass screws in the cervical spine: a biomechanical experiment","volume":"28","author":"Koo","year":"2015","journal-title":"J Spinal Disord Tech"},{"key":"R13-20240205","doi-asserted-by":"crossref","first-page":"193","DOI":"10.3340\/jkns.2010.48.3.193","article-title":"Comparative analysis of three different cervical lateral mass screw fixation techniques by complications and bicortical purchase: cadaveric study","volume":"48","author":"Baek","year":"2010","journal-title":"J Korean Neurosurg Soc"},{"key":"R14-20240205","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1097\/BRS.0b013e31816b4666","article-title":"Quantitative anatomy of subaxial cervical lateral mass: an analysis of safe screw lengths for Roy-Camille and magerl techniques","volume":"33","author":"Stemper","year":"2008","journal-title":"Spine"},{"key":"R15-20240205","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/S1529-9430(02)00461-8","article-title":"Anatomic consideration for standard and modified techniques of cervical lateral mass screw placement","volume":"2","author":"Merola","year":"2002","journal-title":"Spine J"},{"key":"R16-20240205","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1097\/BRS.0b013e31816957a7","article-title":"Vertebral artery injury during cervical spine surgery: a survey of more than 5600 operations","volume":"33","author":"Neo","year":"2008","journal-title":"Spine"},{"key":"R17-20240205","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/00002517-199806000-00011","article-title":"Modified Magerl technique of lateral mass screw placement in the lower cervical spine: an anatomic study","volume":"11","author":"Xu","year":"1998","journal-title":"J Spinal Disord"},{"key":"R18-20240205","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1097\/00007632-199808150-00006","article-title":"Safe lateral-mass screw lengths in the Roy-Camille and Magerl techniques. An anatomic study","volume":"23","author":"Ebraheim","year":"1998","journal-title":"Spine"},{"issue":"(10 suppl)","key":"R19-20240205","doi-asserted-by":"crossref","first-page":"S552","DOI":"10.1097\/00007632-199110001-00020","article-title":"Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine","volume":"16","author":"Heller","year":"1991","journal-title":"Spine"},{"key":"R20-20240205","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1097\/00007632-199602010-00014","article-title":"Posterior cervical arthrodesis and stabilization with a lateral mass plate. Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications","volume":"21","author":"Graham","year":"1996","journal-title":"Spine"},{"key":"R21-20240205","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1097\/00007632-199603150-00007","article-title":"Evaluation of cervical posterior lateral mass screw placement by oblique radiographs","volume":"21","author":"Xu","year":"1996","journal-title":"Spine"},{"key":"R22-20240205","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1016\/j.spinee.2009.02.008","article-title":"Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement","volume":"9","author":"Yeom","year":"2009","journal-title":"Spine J"},{"key":"R23-20240205","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1097\/00007632-199802150-00010","article-title":"Lateral radiologic evaluation of lateral mass screw placement in the cervical spine","volume":"23","author":"Ebraheim","year":"1998","journal-title":"Spine"}],"container-title":["Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00007632-201707150-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T01:26:08Z","timestamp":1707096368000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00007632-201707150-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,15]]},"references-count":23,"journal-issue":{"issue":"14","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/brs.0000000000001985","relation":{},"ISSN":["0362-2436","1528-1159"],"issn-type":[{"value":"0362-2436","type":"print"},{"value":"1528-1159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,7,15]]}}}