{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T22:20:23Z","timestamp":1765232423779},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"20","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,10,15]]},"abstract":"<jats:sec>\n            <jats:title>Study Design.<\/jats:title>\n            <jats:p>Retrospective comparative study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective.<\/jats:title>\n            <jats:p>To compare the outcomes of C1-C2 transarticular screw with C1 laminar hook (TAS\u200a+\u200aC1H) fixation and C1 trans-arch lateral mass screw with C2 pedicle screw (C1TLMS\u200a+\u200aC2PS) fixation in the treatment of reducible atlantoaxial dislocation (AAD).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data.<\/jats:title>\n            <jats:p>TAS\u200a+\u200aC1H is comparable to TAS with posterior wiring techniques and superior to C1 lateral mass screw combined with C2 pedicle screw (C1LMS\u200a+\u200aC2PS) in biomechanics. There were, however, few studies analyzing the differences in outcomes between TAS\u200a+\u200aC1H technique and modified C1LMS\u200a+\u200aC2PS technique (C1TLMS\u200a+\u200aC2PS) for treating AAD.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods.<\/jats:title>\n            <jats:p>Data of 30 patients with reducible AAD treated by TAS\u200a+\u200aC1H fixation and another 30 cases treated by C1TLMS\u200a+\u200aC2PS fixation were retrospectively analyzed. Bone fusion time was recorded. The outcomes evaluated by American Spinal Injury Association impairment scale, visual analog scale score for neck pain, neck stiffness (none\/mild\/severe), patient satisfaction, and Neck Disability Index (NDI) were compared between two groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results.<\/jats:title>\n            <jats:p>There were no complications related to the surgical approach and instrumentation in either group. At the final follow-up, bone graft fusion rates were 100% in both the TAS\u200a+\u200aC1H fixation group and the C1TLMS\u200a+\u200aC2PS fixation group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&gt;\u200a0.05). The neurological status evaluated by American Spinal Injury Association impairment scale were greatly improved in both screw-hook group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a0.001) and screw-rod group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a0.001), but with no significant differences between groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&gt;\u200a0.05). There were no significant differences between two groups in visual analog scale score for neck pain, neck stiffness, patient satisfaction, or Neck Disability Index (all <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&gt;\u200a0.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion.<\/jats:title>\n            <jats:p>C1TLMS\u200a+\u200aC2PS fixation was comparable to TAS\u200a+\u200aC1H fixation in fusion rate and functional outcomes for treating reducible AAD. To reduce the risk of vertebral artery injury, computed tomography scan, and reconstruction should be done to analyze vertebral artery course and C1-C2 anatomic structures before operation.<\/jats:p>\n            <jats:p>\n                                 <jats:bold>Level of Evidence:<\/jats:bold> 3<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/brs.0000000000002152","type":"journal-article","created":{"date-parts":[[2017,3,14]],"date-time":"2017-03-14T14:42:44Z","timestamp":1489502564000},"page":"1587-1593","source":"Crossref","is-referenced-by-count":9,"title":["Comparison of Outcomes Between C1-C2 Screw-Hook Fixation and C1-C2 Screw-Rod Fixation for Treating Reducible Atlantoaxial Dislocation"],"prefix":"10.1097","volume":"42","author":[{"given":"Bin","family":"Ni","sequence":"first","affiliation":[{"name":"Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenlong","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qunfeng","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Traditional Chinese Medicine Rehabilitation, Zhabei Central Hospital, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinshui","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Fuzhou General Hospital, Fuzhou, People's Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiang","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuhua","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Xie","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20240205","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/S0002-9610(39)90309-0","article-title":"Fractures and dislocations of the cervical spine","volume":"46","author":"Gallie","year":"1939","journal-title":"Am J Surg"},{"key":"R2-20240205","doi-asserted-by":"crossref","first-page":"279","DOI":"10.2106\/00004623-197860030-00001","article-title":"Atlanto-axial arthrodesis by the wedge compression method","volume":"60","author":"Brooks","year":"1978","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20240205","doi-asserted-by":"crossref","first-page":"190","DOI":"10.3171\/jns.1991.74.2.0190","article-title":"The interspinous method of posterior atlantoaxial arthrodesis","volume":"74","author":"Dickman","year":"1991","journal-title":"J Neurosurg"},{"key":"R4-20240205","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1227\/01.NEU.0000365798.53288.A3","article-title":"Atlantoaxial transarticular screw fixation: update on technique and outcomes in 269 patients","volume":"66","author":"Finn","year":"2010","journal-title":"Neurosurgery"},{"key":"R5-20240205","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-7091-8882-8_59","article-title":"Stable posterior fusion of the atlas by transarticular screw fixation","author":"Magerl","year":"1987","journal-title":"Cervical Spine I"},{"key":"R6-20240205","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20240205","doi-asserted-by":"crossref","first-page":"E401","DOI":"10.1097\/BRS.0b013e31820611ba","article-title":"Biomechanical evaluations of various c1-c2 posterior fixation techniques","volume":"36","author":"Sim","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R8-20240205","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1097\/00006123-200212000-00004","article-title":"Atlantoaxial fixation using plate and screw method: a report of 160 treated patients","volume":"51","author":"Goel","year":"2002","journal-title":"Neurosurgery"},{"key":"R9-20240205","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1097\/01.brs.0000257539.75693.cc","article-title":"Atlantoaxial transarticular screw fixation with morselized autograft and without additional internal fixation: technical description and report of 57 cases","volume":"32","author":"Wang","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R10-20240205","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1227\/01.NEU.0000365804.75511.E2","article-title":"C1 lateral mass fixation: a comparison of constructs","volume":"66","author":"Mummaneni","year":"2010","journal-title":"Neurosurgery"},{"key":"R11-20240205","doi-asserted-by":"crossref","first-page":"e87676","DOI":"10.1371\/journal.pone.0087676","article-title":"Bilateral C1-C2 transarticular screw and C1 laminar hook fixation and bone graft fusion for reducible atlantoaxial dislocation: a seven-year analysis of outcome","volume":"9","author":"Guo","year":"2014","journal-title":"PLoS One"},{"key":"R12-20240205","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1097\/BSD.0b013e31818da3fe","article-title":"Biomechanical assessment of bilateral C1 laminar hook and C1-2 transarticular screws and bone graft for atlantoaxial instability","volume":"22","author":"Guo","year":"2009","journal-title":"J Spinal Disord Tech"},{"key":"R13-20240205","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.wneu.2016.04.014","article-title":"Posterior open reduction and interlaminae compression fusion for Os odontoideum with atlantoaxial dislocation","volume":"91","author":"Ni","year":"2016","journal-title":"World Neurosurg"},{"key":"R14-20240205","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1016\/S0140-6736(74)90884-8","article-title":"Measurement of pain","volume":"2","author":"Huskisson","year":"1974","journal-title":"Lancet"},{"key":"R15-20240205","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1097\/00007632-198805000-00002","article-title":"Fractures of the atlas: classification, treatment and morbidity","volume":"13","author":"Landells","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"key":"R16-20240205","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1007\/s00586-011-2069-y","article-title":"Rigid cervical collar treatment for geriatric type II odontoid fractures","volume":"21","author":"Molinari","year":"2012","journal-title":"Eur Spine J"},{"key":"R17-20240205","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0004-9514(05)70017-9","article-title":"The Neck Disability Index (NDI)","volume":"51","author":"Sterling","year":"2005","journal-title":"Aust J Physiother"},{"key":"R18-20240205","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1007\/s00586-011-1958-4","article-title":"Modified technique for C1-2 screw-rod fixation and fusion using autogenous bicortical iliac crest graft","volume":"21","author":"Ni","year":"2012","journal-title":"Eur Spine J"},{"key":"R19-20240205","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1097\/00007632-200208150-00008","article-title":"Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques","volume":"27","author":"Richter","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R20-20240205","doi-asserted-by":"crossref","first-page":"155","DOI":"10.3171\/spi.2005.2.2.0155","article-title":"Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients","volume":"2","author":"Gluf","year":"2005","journal-title":"J Neurosurg Spine"},{"key":"R21-20240205","first-page":"65","article-title":"C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience","volume":"49","author":"Haid","year":"2001","journal-title":"Neurosurgery"},{"key":"R22-20240205","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF01400872","article-title":"Plate and screw fixation for atlanto-axial subluxation","volume":"129","author":"Goel","year":"1994","journal-title":"Acta Neurochir (Wien)"},{"key":"R23-20240205","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1097\/01.BRS.0000058719.48596.CC","article-title":"Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass","volume":"28","author":"Tan","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R24-20240205","first-page":"426","article-title":"C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note","volume":"50","author":"Resnick","year":"2002","journal-title":"Neurosurgery"},{"key":"R25-20240205","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.wneu.2016.04.126","article-title":"Biomechanical evaluation of a novel integrated C1 laminar hook combined with C1-C2 transarticular screws for atlantoaxial fusion: an in vitro human cadaveric study","volume":"92","author":"Xu","year":"2016","journal-title":"World Neurosurg"},{"key":"R26-20240205","doi-asserted-by":"crossref","first-page":"961","DOI":"10.3171\/jns.1997.86.6.0961","article-title":"Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique","volume":"86","author":"Madawi","year":"1997","journal-title":"J Neurosurg"},{"key":"R27-20240205","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3171\/jns.1998.88.4.0634","article-title":"Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS\/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons\/Congress of Neurological Surgeons","volume":"88","author":"Wright","year":"1998","journal-title":"J Neurosurg"},{"key":"R28-20240205","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1097\/BRS.0b013e31816957a7","article-title":"Vertebral artery injury during cervical spine surgery: a survey of more than 5600 operations","volume":"33","author":"Neo","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R29-20240205","doi-asserted-by":"crossref","first-page":"247","DOI":"10.3171\/spi.2007.6.3.247","article-title":"Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation","volume":"6","author":"Rocha","year":"2007","journal-title":"J Neurosurg Spine"},{"key":"R30-20240205","doi-asserted-by":"crossref","first-page":"E513","DOI":"10.1097\/01.brs.0000224516.29747.52","article-title":"Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw","volume":"31","author":"Yoshida","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R31-20240205","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1007\/s00402-011-1277-6","article-title":"C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury","volume":"131","author":"Guo","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"R32-20240205","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/00024720-200404000-00014","article-title":"Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note","volume":"17","author":"Wright","year":"2004","journal-title":"J Spinal Disord Tech"}],"container-title":["Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00007632-201710150-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T02:00:42Z","timestamp":1707098442000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00007632-201710150-00018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,15]]},"references-count":32,"journal-issue":{"issue":"20","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/brs.0000000000002152","relation":{},"ISSN":["0362-2436","1528-1159"],"issn-type":[{"value":"0362-2436","type":"print"},{"value":"1528-1159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,15]]}}}