{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T00:56:03Z","timestamp":1793235363128,"version":"4.5.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5,15]]},"abstract":"<jats:sec>\n            <jats:title>Study Design.<\/jats:title>\n            <jats:p>Screw randomized cadaveric study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective.<\/jats:title>\n            <jats:p>To compare the accuracy of three-dimensional (3D)-printed drill guides <jats:italic toggle=\"yes\">versus<\/jats:italic> additional screw guiding techniques for challenging intra- and extrapedicular screw trajectories.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data.<\/jats:title>\n            <jats:p>Pedicle screw placement can be technically demanding, especially in syndromic scoliosis with limited bone stock. Recently, 3D-printing and virtual planning technology have become available as new tools to improve pedicle screw insertion. Differences in techniques exist, while some focus on guiding the drill, others also actively guide subsequent screws insertion. The accuracy of various 3D-printing-assisted techniques has been studied; however, direct comparative studies have yet to determine whether there is a benefit of additional screw guidance.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods.<\/jats:title>\n            <jats:p>Two cadaveric experiments were conducted to compare drill guides with two techniques that introduce additional screw guiding. The screw guiding consisted of either k-wire cannulated screws or modular guides, which were designed to guide the screw in addition to the drill bit. Screws were inserted intra- or extrapedicular using one of each methods according to a randomization scheme. Postoperative computed tomography scanning was performed and fused with the preoperative planning for detailed 3D screw deviation analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results.<\/jats:title>\n            <jats:p>For <jats:italic toggle=\"yes\">intrapedicular<\/jats:italic> screw trajectories malpositioning was low (2%) and the modular guides revealed a statistically significant increase of accuracy <jats:italic toggle=\"yes\">(P<\/jats:italic>\u200a\n                                 <jats:italic toggle=\"yes\">=<\/jats:italic>\u200a0.05) compared with drill guides. All techniques showed accurate cervical screw insertion without breach. For the <jats:italic toggle=\"yes\">extrapedicular<\/jats:italic> screw trajectories both additional screw guiding methods did not significantly (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a0.09) improve accuracy and malpositioning rates remained high (24%).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions.<\/jats:title>\n            <jats:p>In this cadaveric study it was found that the additional screw-guiding techniques are not superior to the regular 3D-printed drill guides for the technically demanding <jats:italic toggle=\"yes\">extrapedicular<\/jats:italic> screw technique. For <jats:italic toggle=\"yes\">intrapedicular<\/jats:italic> screw insertion, modular guides can improve insertion; however, at cervical levels regular 3D-printed drill guides already demonstrated very high accuracy and therefore there is no benefit from additional screw guiding techniques.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence.<\/jats:title>\n            <jats:p>3<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/brs.0000000000004147","type":"journal-article","created":{"date-parts":[[2021,6,16]],"date-time":"2021-06-16T10:01:03Z","timestamp":1623837663000},"page":"E434-E441","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["A Comparison of Drill Guiding and Screw Guiding 3D-Printing Techniques for Intra- and Extrapedicular Screw Insertion"],"prefix":"10.1097","volume":"47","author":[{"given":"Peter A.J.","family":"Pijpker","sequence":"first","affiliation":[{"name":"University of Groningen, University Medical Center Groningen, Department of Neurosurgery, Groningen, The Netherlands"},{"name":"University of Groningen, University Medical Center Groningen, Department of Orthopedics, Groningen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos M.A.","family":"Kuijlen","sequence":"additional","affiliation":[{"name":"University of Groningen, University Medical Center Groningen, Department of Neurosurgery, Groningen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joep","family":"Kraeima","sequence":"additional","affiliation":[{"name":"University of Groningen, University Medical Center Groningen, Department of Oral and Maxillofacial Surgery, Groningen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rob J.M.","family":"Groen","sequence":"additional","affiliation":[{"name":"University of Groningen, University Medical Center Groningen, Department of Neurosurgery, Groningen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"Faber","sequence":"additional","affiliation":[{"name":"University of Groningen, University Medical Center Groningen, Department of Orthopedics, Groningen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,6,15]]},"reference":[{"key":"R1-20250501","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1097\/00007632-199707150-00002","article-title":"Anatomic relations of the thoracic pedicle to the adjacent neural structures","volume":"22","author":"Ebraheim","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"key":"R2-20250501","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.2106\/00004623-200010000-00013","article-title":"The use of pedicle-screw internal fixation for the operative treatment of spinal disorders","volume":"82","author":"Gaines","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20250501","doi-asserted-by":"crossref","first-page":"1867","DOI":"10.1097\/00007632-199310000-00024","article-title":"Complications of the wiltse pedicle screw fixation system","volume":"18","author":"Blumenthal","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20250501","doi-asserted-by":"crossref","first-page":"2239","DOI":"10.1097\/00007632-199710010-00008","article-title":"Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis","volume":"22","author":"Liljenqvist","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"key":"R5-20250501","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.2106\/00004623-199508000-00009","article-title":"Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment","volume":"77","author":"Vaccaro","year":"1995","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20250501","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1097\/BRS.0b013e31823aff81","article-title":"Application of intraoperative computed tomography with or without navigation system in surgical correction of spinal deformity: a preliminary result of 59 consecutive human cases","volume":"37","author":"Cui","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20250501","doi-asserted-by":"crossref","first-page":"e23","DOI":"10.1097\/BPO.0b013e318263a39e","article-title":"The accuracy of navigation and 3D image-guided placement for the placement of pedicle screws in congenital spine deformity","volume":"32","author":"Larson","year":"2012","journal-title":"J Pediatr Orthop"},{"key":"R8-20250501","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s11517-012-0900-1","article-title":"Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template","volume":"50","author":"Lu","year":"2012","journal-title":"Med Biol Eng Comput"},{"key":"R9-20250501","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1007\/s00586-016-4926-1","article-title":"Preliminary application of a multi-level 3D printing drill guide template for pedicle screw placement in severe and rigid scoliosis","volume":"26","author":"Liu","year":"2017","journal-title":"Eur Spine J"},{"key":"R10-20250501","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.jcot.2018.08.006","article-title":"Current status of 3D printing in spine surgery","volume":"9","author":"Garg","year":"2018","journal-title":"J Clin Orthop Trauma"},{"key":"R11-20250501","doi-asserted-by":"crossref","first-page":"1712","DOI":"10.1007\/s00586-019-05978-3","article-title":"Pedicle screw insertion with patient-specific 3D-printed guides based on low-dose CT scan is more accurate than free-hand technique in spine deformity patients: a prospective, randomized clinical trial","volume":"28","author":"Cecchinato","year":"2019","journal-title":"Eur Spine J"},{"key":"R12-20250501","doi-asserted-by":"crossref","first-page":"E1050","DOI":"10.1097\/BRS.0000000000002067","article-title":"Unilateral spinous process non-covering hook type patient-specific drill template for thoracic pedicle screw fixation","volume":"42","author":"Kim","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"R13-20250501","first-page":"261","article-title":"Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine","volume":"17","author":"Merc","year":"2014","journal-title":"Chin J Traumatol"},{"key":"R14-20250501","doi-asserted-by":"crossref","first-page":"94","DOI":"10.3171\/2015.12.SPINE15678","article-title":"Utility of a custom screw insertion guide and a full-scale, color-coded 3D plaster model for guiding safe surgical exposure and screw insertion during spine revision surgery","volume":"25","author":"Otsuki","year":"2016","journal-title":"J Neurosurg Spine"},{"key":"R15-20250501","doi-asserted-by":"crossref","first-page":"E1314","DOI":"10.1097\/BRS.0b013e31822a82ec","article-title":"The contribution of an electronic conductivity device to the safety of pedicle screw insertion in scoliosis surgery","volume":"36","author":"Ovadia","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R16-20250501","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1097\/00007632-199909150-00011","article-title":"Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography: a prospective study of 35 patients","volume":"24","author":"Sapkas","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"key":"R17-20250501","first-page":"277","article-title":"Probing for thoracic pedicle screw tract violation (s): is it valid?","volume":"17","author":"Lehman","year":"2004","journal-title":"Clin Spine Surg"},{"key":"R18-20250501","doi-asserted-by":"crossref","first-page":"196","DOI":"10.3171\/2013.11.SPINE13413","article-title":"The accuracy of pedicle screw placement using intraoperative image guidance systems: a systematic review","volume":"20","author":"Mason","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"R19-20250501","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1093\/ons\/opy060","article-title":"Accuracy assessment of pedicle and lateral mass screw insertion assisted by customized 3D- printed drill guides: a human cadaver study","volume":"16","author":"Pijpker","year":"2019","journal-title":"Oper Neurosurg (Hagerstown)"},{"key":"R20-20250501","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/BRS.0000000000003747","article-title":"Accuracy of patient-specific 3d-printed drill guides for pedicle and lateral mass screw insertion: an analysis of 76 cervical and thoracic screw trajectories","volume":"46","author":"Pijpker","year":"2021","journal-title":"Spine (Phila Pa 1976)"},{"key":"R21-20250501","doi-asserted-by":"crossref","first-page":"185","DOI":"10.3171\/2013.4.SPINE121059","article-title":"Multistep pedicle screw insertion procedure with patient-specific lamina fit-and- lock templates for the thoracic spine","volume":"19","author":"Sugawara","year":"2013","journal-title":"J Neurosurg Spine"},{"key":"R22-20250501","doi-asserted-by":"crossref","first-page":"e14811","DOI":"10.1097\/MD.0000000000014811","article-title":"Comparison of the accuracy of cannulated pedicle screw versus conventional pedicle screw in the treatment of adolescent idiopathic scoliosis: A randomized retrospective study","volume":"98","author":"Yilar","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"R23-20250501","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1007\/s00586-015-3853-x","article-title":"Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review","volume":"24","author":"Aoude","year":"2015","journal-title":"Eur Spine J"},{"key":"R24-20250501","doi-asserted-by":"crossref","first-page":"590","DOI":"10.3171\/2015.2.PEDS14556","article-title":"Feasibility of CT-based intraoperative 3D stereotactic image-guided navigation in the upper cervical spine of children 10\u200ayears of age or younger: initial experience","volume":"16","author":"Kovanda","year":"2015","journal-title":"J Neurosurg Pediatr"},{"key":"R25-20250501","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.spinee.2005.12.007","article-title":"Pullout resistance of thoracic extrapedicular screws used as a salvage procedure","volume":"7","author":"Y\u00fcsel","year":"2007","journal-title":"Spine J"}],"container-title":["Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BRS.0000000000004147","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T18:11:54Z","timestamp":1746123114000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BRS.0000000000004147"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,15]]},"references-count":25,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/brs.0000000000004147","relation":{},"ISSN":["0362-2436","1528-1159"],"issn-type":[{"value":"0362-2436","type":"print"},{"value":"1528-1159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,15]]}}}