{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T16:38:24Z","timestamp":1794328704835,"version":"4.9.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"23","license":[{"start":{"date-parts":[[2022,10,17]],"date-time":"2022-10-17T00:00:00Z","timestamp":1665964800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,12,1]]},"abstract":"<jats:sec>\n            <jats:title>Study Design.<\/jats:title>\n            <jats:p>Retrospective multicenter.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective.<\/jats:title>\n            <jats:p>The aim was to investigate the factors involved in, and their relative contributions to, the overall accuracy of robot-assisted pedicle screw placement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data.<\/jats:title>\n            <jats:p>Robot-assisted surgery has reportedly resulted in greater accuracy for placement of pedicle screws than conventional methods. There are many potential factors affecting the accuracy of pedicle screws placed with a robot. No study has investigated these factors in a robust way.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods.<\/jats:title>\n            <jats:p>Radiographic and clinical data of three centers were pooled. Preoperative and postoperative computerized tomographies were obtained by all three centers to assess the accuracy of the placed screws. The primary outcome measured was accuracy of pedicle screws placed with the robot. The authors performed a multivariate regression analysis to determine the significant patient-related and screw-related variables and their relative contribution to the overall accuracy. In addition, an ordinal regression analysis was conducted to investigate the effects of different variables on accuracy of robot-placed screws graded by Gertzbein-Robbins grading system (GRS).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results.<\/jats:title>\n            <jats:p>The total contribution of all studied variables to overall accuracy variation as measured by offsets between the placed and planned screws was only 18%. Obesity, long constructs, female gender, surgeon, and vertebral levels were among the factors that had small contributions to the different screw offsets. For GRS grades, significant variables were gender (Log odds: 0.62, 95% CI: 0.38\u20130.85), age (Log odds: 0.02, 95% CI: 0.01\u20130.03), length of constructs (Log odds: 0.07, 95% CI: 0.02\u20130.11), screw diameter (Log odds: 0.55, 95% CI: 0.39\u20130.71), and length of the screws (Log odds: 0.03, 95% CI: 0.01\u20130.05). However, these variables too, regardless of their significant association with the accuracy of placed screws, had little contribution to overall variability of accuracy itself (only about 7%).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion.<\/jats:title>\n            <jats:p>The accuracy of screws placed with robotic assistance, as graded by GRS or measured offsets between planned and placed screw trajectories, is minimally affected by different patient-related or screw-related variables due to the robustness of the robotic navigation system used in this study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence.<\/jats:title>\n            <jats:p>Level III.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/brs.0000000000004473","type":"journal-article","created":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T18:00:08Z","timestamp":1666116008000},"page":"1613-1619","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":15,"title":["Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery"],"prefix":"10.1097","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4167-2976","authenticated-orcid":false,"given":"Nader","family":"Toossi","sequence":"first","affiliation":[{"name":"Musculoskeletal Education and Research Center (MERC), Audubon, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnold B.","family":"Vardiman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Texas Health, San Antonio, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo A.","family":"Benech","sequence":"additional","affiliation":[{"name":"Department of Neurology and Clinical Neurophysiology, Fornaca Clinic, Turin, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles W.","family":"Kanaly","sequence":"additional","affiliation":[{"name":"The Spine Center of Saint Anne\u2019s Hospital, Fall River, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitchell G.","family":"Maltenfort","sequence":"additional","affiliation":[{"name":"Applied Clinical Research Center, Children\u2019s Hospital of Philadelphia, Philadelphia, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danielle M.","family":"Backes","sequence":"additional","affiliation":[{"name":"Neurosurgery Center of Southern New England, PC, Fall River, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon","family":"Bucklen","sequence":"additional","affiliation":[{"name":"Musculoskeletal Education and Research Center (MERC), Audubon, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,10,17]]},"reference":[{"key":"R1-20250501","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/BRS.0000000000000100","article-title":"Robot-assisted vertebral body augmentation: a radiation reduction tool","volume":"39","author":"Barzilay","year":"2014","journal-title":"Spine"},{"key":"R2-20250501","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1111\/os.13056","article-title":"Percutaneous robot-assisted versus freehand S2 iliosacral screw fixation in unstable posterior pelvic ring fracture","volume":"14","author":"Han","year":"2022","journal-title":"Orthop Surg"},{"key":"R3-20250501","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/BRS.0000000000001778","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial","volume":"42","author":"Hyun","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"issue":"suppl 1","key":"R4-20250501","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1227\/NEU.0b013e318270d02c","article-title":"Spinal robotics: current applications and future perspectives","volume":"72","author":"Roser","year":"2013","journal-title":"Neurosurgery"},{"key":"R5-20250501","doi-asserted-by":"crossref","DOI":"10.1002\/rcs.1779","article-title":"A prospective, randomized, controlled trial of robot-assisted vs freehand pedicle screw fixation in spine surgery","volume":"13","author":"Kim","year":"2017","journal-title":"Int J Med Robot"},{"key":"R6-20250501","doi-asserted-by":"crossref","first-page":"E496","DOI":"10.1097\/BRS.0b013e31824b7767","article-title":"Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation","volume":"37","author":"Ringel","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20250501","first-page":"4","article-title":"Pedicle screw insertion in spine: a randomized comparison study of robot-assisted surgery and fluoroscopy-guided techniques","volume":"1","author":"Tian","year":"2016","journal-title":"J Clin Orthop Res"},{"key":"R8-20250501","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/2018.10.SPINE18487","article-title":"Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial","volume":"30","author":"Han","year":"2019","journal-title":"J Neurosurg Spine"},{"key":"R9-20250501","doi-asserted-by":"crossref","first-page":"e2054","DOI":"10.1002\/rcs.2054","article-title":"Navigated robotic assistance improves pedicle screw accuracy in minimally invasive surgery of the lumbosacral spine: 600 pedicle screws in a single institution","volume":"16","author":"Wallace","year":"2020","journal-title":"Int J Med Robot"},{"key":"R10-20250501","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s11701-019-01007-z","article-title":"Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 cases","volume":"14","author":"Benech","year":"2020","journal-title":"J Robot Surg"},{"key":"R11-20250501","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1007\/s11701-019-01019-9","article-title":"Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery?","volume":"14","author":"Vardiman","year":"2020","journal-title":"J Robot Surg"},{"key":"R12-20250501","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/2020.3.SPINE20208","article-title":"Three-dimensional assessment of robot-assisted pedicle screw placement accuracy and instrumentation reliability based on a preplanned trajectory","volume":"33","author":"Jiang","year":"2020","journal-title":"J Neurosurg Spine"},{"key":"R13-20250501","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine (Phila Pa 1976)"},{"key":"R15-20250501","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v082.i13","article-title":"lmerTest package: tests in linear mixed effects models","volume":"82","author":"Kuznetsova","year":"2017","journal-title":"J Stat Softw"},{"key":"R17-20250501","doi-asserted-by":"crossref","first-page":"S56","DOI":"10.14444\/8140","article-title":"Role of robotics in adult spinal deformity","volume":"15","author":"Cronin","year":"2021","journal-title":"Int J Spine Surg"},{"key":"R18-20250501","first-page":"240","article-title":"Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy","volume":"78","author":"Schizas","year":"2012","journal-title":"Acta Orthop Belg"},{"key":"R19-20250501","doi-asserted-by":"crossref","first-page":"E496","DOI":"10.1097\/BRS.0b013e31824b7767","article-title":"Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation","volume":"37","author":"Ringel","year":"2012","journal-title":"Spine"},{"key":"R20-20250501","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.2106\/00004623-200605000-00036","article-title":"Revised grades of recommendation for summaries or reviews of orthopaedic surgical studies","volume":"88","author":"Wright","year":"2006","journal-title":"JBJS"},{"key":"R21-20250501","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.2106\/JBJS.17.01397","article-title":"Robotic technology in orthopaedic surgery","volume":"100","author":"Chen","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"R22-20250501","doi-asserted-by":"crossref","first-page":"S28","DOI":"10.14444\/8138","article-title":"Spine image guidance and robotics: exposure, education, training, and the learning curve","volume":"15","author":"Judy","year":"2021","journal-title":"Int J Spine Surg"},{"key":"R23-20250501","doi-asserted-by":"crossref","first-page":"141","DOI":"10.21037\/jss-20-687","article-title":"Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes","volume":"7","author":"Avrumova","year":"2021","journal-title":"J Spine Surg"},{"key":"R24-20250501","first-page":"636","article-title":"Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison","volume":"20","author":"Schatlo","year":"2014","journal-title":"J Neurosurg"},{"key":"R25-20250501","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/MD.0000000000005835","article-title":"Pedicle screw placement accuracy of bone-mounted miniature robot system","volume":"96","author":"Tsai","year":"2017","journal-title":"Medicine (Baltimore)"}],"container-title":["Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BRS.0000000000004473","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T18:11:51Z","timestamp":1746123111000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BRS.0000000000004473"}},"subtitle":["A Multicenter Study"],"short-title":[],"issued":{"date-parts":[[2022,10,17]]},"references-count":23,"journal-issue":{"issue":"23","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/brs.0000000000004473","relation":{},"ISSN":["0362-2436"],"issn-type":[{"value":"0362-2436","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10,17]]},"assertion":[{"value":"2022-03-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}