{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:38:21Z","timestamp":1787009901923,"version":"build-2736575974"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"19","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10,1]]},"abstract":"<jats:sec>\n                    <jats:title>Study Design.<\/jats:title>\n                    <jats:p>Cadaveric study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective.<\/jats:title>\n                    <jats:p>To assess the feasibility and accuracy of robotic positioning of thoracic pedicle screws based on magnetic resonance imaging (MRI).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data.<\/jats:title>\n                    <jats:p>Robotic-assisted navigation (RAN) has demonstrated enhanced precision in thoracic pedicle screw placement. Currently, preoperative computer tomography (CT) scanning is required, exposing patients to radiation\u2014a particular concern for younger patients undergoing multilevel fusion surgery. CT-like three-dimensional (3D)-MRI sequences may offer a radiation-free alternative, but their application in thoracic pedicle screw placement remains unexplored.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods.<\/jats:title>\n                    <jats:p>CT-like 3D-MRI scans of the thoracic spine were obtained in two human cadaveric specimens. A RAN system was employed to plan and guide 48 pedicle screws (bilateral screws in thoracic vertebrae T1-T12) using these MRI scans. Following the placement of the pedicle screws, post-procedure CT scans were obtained to evaluate the accuracy of screw positioning. Accuracy was assessed by comparing the actual placement to the pre-procedure plan (difference in millimetres) and via the Gertzbein-Robbins scale (GRS).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results.<\/jats:title>\n                    <jats:p>A total of 48 thoracic pedicle screws were inserted robotically in two human specimens (T1-T12 bilaterally). Post-procedure CT scan evaluations revealed that all screws achieved an acceptable grade on the GRS (A or B). Specifically, 87.5% of the screws were classified as grade A and 12.5% were classified as grade B. The median deviations from the planned trajectory were 0.4\u00a0mm in the axial (IQR: 0.0; 1.2\u00a0mm) and 0.05\u00a0mm in the sagittal (IQR: \u22120.3; 0.3\u00a0mm) planes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions.<\/jats:title>\n                    <jats:p>This cadaveric study demonstrates that MRI-based RAN can accurately guide thoracic pedicle screw placement. The findings suggest MRI-based RAN could provide a radiation-free alternative for thoracic spine instrumentation, particularly beneficial for pediatric and adolescent patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/brs.0000000000005366","type":"journal-article","created":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T07:00:09Z","timestamp":1744786809000},"page":"E397-E403","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Feasibility and Accuracy of Robotic-Assisted Navigation for Thoracic Pedicle Screw Placement Using CT-Like 3D-MRI"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5497-6808","authenticated-orcid":false,"given":"Franziska C.S.","family":"Altorfer","sequence":"first","affiliation":[{"name":"Department of Spine Surgery, Hospital for Special Surgery, New York, NY"},{"name":"University Spine Center Z\u00fcrich, Balgrist University Hospital, University of Z\u00fcrich, Z\u00fcrich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Kelly","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Loggia","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fedan","family":"Avrumova","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaqi","family":"Zhu","sequence":"additional","affiliation":[{"name":"Biostatistics Core, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gracyn","family":"Campbell","sequence":"additional","affiliation":[{"name":"Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Levi","family":"Chazen","sequence":"additional","affiliation":[{"name":"Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ek T.","family":"Tan","sequence":"additional","affiliation":[{"name":"Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darren R.","family":"Lebl","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,16]]},"reference":[{"key":"R1-20251003","doi-asserted-by":"crossref","first-page":"2603","DOI":"10.1007\/s00586-014-3356-1","article-title":"Optimal surgical care for adolescent idiopathic scoliosis: an international consensus","volume":"23","author":"De Kleuver","year":"2014","journal-title":"Eur Spine J"},{"key":"R2-20251003","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/S0030-5898(05)70050-X","article-title":"Thoracic and lumbar trauma","volume":"29","author":"McCullen","year":"1998","journal-title":"Orthop Clin North Am"},{"key":"R3-20251003","doi-asserted-by":"crossref","first-page":"2122","DOI":"10.1097\/01.BRS.0000084266.37210.85","article-title":"Thoracolumbar deformity arthrodesis to L5 in adults: The fate of the L5-S1 disc","volume":"28","author":"Edwards","year":"2003","journal-title":"Spine"},{"key":"R4-20251003","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1097\/00007632-199406000-00014","article-title":"Morphometric study of the pedicles of thoracic and lumbar vertebrae in Koreans","volume":"19","author":"Kim","year":"1994","journal-title":"Spine"},{"key":"R5-20251003","doi-asserted-by":"crossref","first-page":"1850","DOI":"10.1097\/00007632-199310000-00021","article-title":"Pedicle morphology of the lower thoracic and lumbar spine in a Chinese population","volume":"18","author":"Hou","year":"1993","journal-title":"Spine"},{"key":"R6-20251003","doi-asserted-by":"crossref","first-page":"E417","DOI":"10.1097\/BRS.0000000000001846","article-title":"CT radiation dose reduction in robot-assisted pediatric spinal surgery","volume":"42","author":"Sensakovic","year":"2017","journal-title":"Spine"},{"key":"R7-20251003","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","article-title":"Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis","volume":"23","author":"Matur","year":"2023","journal-title":"Spine J"},{"key":"R8-20251003","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1007\/s00586-010-1577-5","article-title":"Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies","volume":"20","author":"Tian","year":"2011","journal-title":"Eur Spine J"},{"key":"R9-20251003","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.spinee.2024.01.007","article-title":"Intraoperative navigation increases the projected lifetime cancer risk in patients undergoing surgery for adolescent idiopathic scoliosis","volume":"24","author":"Striano","year":"2024","journal-title":"Spine J"},{"key":"R10-20251003","doi-asserted-by":"crossref","first-page":"20220059","DOI":"10.1259\/bjr.20220059","article-title":"Zero-TE MRI: principles and applications in the head and neck","volume":"95","author":"Wiesinger","year":"2022","journal-title":"Br J Radiol"},{"key":"R11-20251003","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1002\/nbm.2783","article-title":"High-resolution ZTE imaging of human teeth","volume":"25","author":"Weiger","year":"2012","journal-title":"NMR Biomed"},{"key":"R12-20251003","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1177\/21925682241232328","article-title":"Robot-assisted lumbar pedicle screw placement based on 3D magnetic resonance imaging","volume":"15","author":"Altorfer","year":"2025","journal-title":"Global Spine J"},{"key":"R13-20251003","doi-asserted-by":"crossref","first-page":"CASE23120","DOI":"10.3171\/CASE23120","article-title":"Robot-assisted screw fixation in a cadaver utilizing magnetic resonance imaging\u2013based synthetic computed tomography: toward radiation-free spine surgery. Illustrative case","volume":"6","author":"Davidar","year":"2023","journal-title":"J Neurosurg Case Lessons"},{"key":"R14-20251003","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.spinee.2024.10.020","article-title":"Robotic pedicle screw placement with 3D MRI registration: moving towards radiation free robotic spine surgery","volume":"25","author":"Altorfer","year":"2025","journal-title":"Spine J"},{"key":"R15-20251003","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine (Phila Pa 1976)"},{"key":"R16-20251003","doi-asserted-by":"crossref","first-page":"E986","DOI":"10.1097\/BRS.0000000000000960","article-title":"Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy","volume":"40","author":"Van Dijk","year":"2015","journal-title":"Spine"},{"key":"R17-20251003","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1302\/0301-620X.105B5.BJJ-2022-0810.R3","article-title":"Robotic-navigated assistance in spine surgery: a single-surgeon experience with 1,001 pedicle screws","volume":"105-B","author":"Abel","year":"2023","journal-title":"Bone Joint J"},{"key":"R18-20251003","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1097\/BRS.0000000000001099","article-title":"Accuracy of pedicle screw placement with robotic guidance system: a cadaveric study","volume":"40","author":"Fujishiro","year":"2015","journal-title":"Spine"},{"key":"R19-20251003","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1097\/BRS.0b013e3181d323ab","article-title":"Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study","volume":"35","author":"Devito","year":"2010","journal-title":"Spine"},{"key":"R20-20251003","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1227\/00006123-199508000-00016","article-title":"Anatomy of the thoracic pedicle","volume":"37","author":"McCormack","year":"1995","journal-title":"Neurosurgery"},{"key":"R21-20251003","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/BRS.0000000000001778","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial","volume":"42","author":"Hyun","year":"2017","journal-title":"Spine"},{"key":"R22-20251003","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.rpor.2018.09.010","article-title":"Optimizing MRI sequences and images for MRI-based stereotactic radiosurgery treatment planning","volume":"24","author":"Taghizadeh","year":"2019","journal-title":"Rep Pract Oncol Radiother"},{"key":"R23-20251003","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1097\/BRS.0000000000004685","article-title":"Projected lifetime cancer risk associated with intraoperative computed tomography for lumbar spine surgery","volume":"48","author":"Crawford","year":"2023","journal-title":"Spine"},{"key":"R24-20251003","doi-asserted-by":"crossref","first-page":"141","DOI":"10.21037\/jss-20-687","article-title":"Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes","volume":"7","author":"Avrumova","year":"2021","journal-title":"J Spine Surg"}],"container-title":["Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BRS.0000000000005366","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T21:01:25Z","timestamp":1759525285000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BRS.0000000000005366"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,16]]},"references-count":24,"journal-issue":{"issue":"19","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/brs.0000000000005366","relation":{},"ISSN":["0362-2436","1528-1159"],"issn-type":[{"value":"0362-2436","type":"print"},{"value":"1528-1159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,16]]},"assertion":[{"value":"2025-01-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}