{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T22:46:07Z","timestamp":1774478767414,"version":"3.50.1"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,2]]},"DOI":"10.1097\/bsd.0000000000000042","type":"journal-article","created":{"date-parts":[[2013,10,25]],"date-time":"2013-10-25T12:28:04Z","timestamp":1382704084000},"page":"E1-E8","source":"Crossref","is-referenced-by-count":23,"title":["Radiographic Analysis of One-level Minimally Invasive Transforaminal Lumbar Interbody Fusion (MI-TLIF) With Unilateral Pedicle Screw Fixation for Lumbar Degenerative Diseases"],"prefix":"10.1097","volume":"29","author":[{"given":"Xiaolong","family":"Shen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hailong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Gu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guangfei","family":"Gu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shisheng","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-8-20210204","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s00064-006-0112-7","article-title":"Die posteriore, lumbale, interkorporalle fusion in unilateraler transforminaler technik.","volume":"10","author":"Harms","year":"1998","journal-title":"Orthop Traumatol"},{"key":"R2-8-20210204","doi-asserted-by":"crossref","first-page":"2300","DOI":"10.1007\/s00586-012-2376-y","article-title":"Minimally invasive transforaminal lumber interbody fusion and degenerative lumbar spine disease.","volume":"21","author":"Tsahtsarlis","year":"2012","journal-title":"Eur Spine J"},{"key":"R3-8-20210204","first-page":"499","article-title":"Advances in minimally invasive spine surgery.","volume":"49","author":"Foley","year":"2002","journal-title":"Clin Neurosurg"},{"key":"R4-8-20210204","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1007\/s00264-008-0687-8","article-title":". Minimally invasive versus open transforaminal lumbar interbody fusion: Evaluating initial experience.","volume":"33","author":"Schizas","year":"2009","journal-title":"Int Orthop"},{"key":"R5-8-20210204","doi-asserted-by":"crossref","first-page":"E65","DOI":"10.1097\/01.BRS.0000113034.74567.86","article-title":". Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine.","volume":"29","author":"Harris","year":"2004","journal-title":"Spine"},{"key":"R6-8-20210204","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.spinee.2005.08.003","article-title":". Less invasive posterior fixation method following transforaminal lumbar interbody fusion: a biomechanical analysis.","volume":"6","author":"Slucky","year":"2006","journal-title":"Spine J"},{"key":"R7-8-20210204","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/foc.2006.20.3.11","article-title":"Minimally invasive transforaminal lumbar interbody fusion with unilateral pedicle screw fixation.","volume":"20","author":"Deutsch","year":"2006","journal-title":"Neurosurg Focus"},{"key":"R8-8-20210204","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/foc.2001.10.4.11","article-title":". Percutaneous pedicle screw fixation of the lumbar spine.","volume":"10","author":"Foley","year":"2001","journal-title":"Neurosurg Focus"},{"key":"R9-8-20210204","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/S1076-6332(97)80078-5","article-title":". Computer-assisted measurement of lumbar spine radiographs.","volume":"4","author":"Quint","year":"1997","journal-title":"Acad Radiol"},{"key":"R10-8-20210204","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/foc.2001.10.4.12","article-title":". Surgical interbody research groupradiographic assessment of interbody fusion devices: Fusion criteria for anterior lumbar interbody surgery.","volume":"10","author":"Burkus","year":"2001","journal-title":"Neurosurg Focus"},{"key":"R11-8-20210204","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1007\/s002560050566","article-title":". Radiographic evaluation of the lumbosacral disc height.","volume":"28","author":"Inoue","year":"1999","journal-title":"Skeletal Radiol"},{"key":"R12-8-20210204","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/00002517-199203000-00006","article-title":". Isolated l4-l5 fusions using the variable screw placement system: unilateral versus bilateral.","volume":"5","author":"Kabins","year":"1992","journal-title":"J Spinal Disord"},{"key":"R13-8-20210204","doi-asserted-by":"crossref","first-page":"1843","DOI":"10.1097\/00007632-200007150-00017","article-title":". Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion.","volume":"25","author":"Suk","year":"2000","journal-title":"Spine"},{"key":"R14-8-20210204","doi-asserted-by":"crossref","first-page":"E92","DOI":"10.1097\/01.brs.0000153703.80747.16","article-title":". Biomechanical analysis of unilateral fixation with interbody cages.","volume":"30","author":"Chen","year":"2005","journal-title":"Spine"},{"key":"R15-8-20210204","doi-asserted-by":"crossref","first-page":"E4","DOI":"10.3171\/foc.2006.20.3.5","article-title":"Unilateral pedicle screw instrumentation for minimally invasive transforaminal lumbar interbody fusion.","volume":"20","author":"Beringer","year":"2006","journal-title":"Neurosurg Focus"},{"key":"R17-8-20210204","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3340\/jkns.2009.46.1.5","article-title":". Unilateral augmented pedicle screw fixation for foraminal stenosis.","volume":"46","author":"Kim","year":"2009","journal-title":"J Korean Neurosurg Soc"},{"key":"R18-8-20210204","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1007\/s00586-008-0825-4","article-title":"Transforaminal lumbar interbody fusion using unilateral pedicle screws and a translaminar screw.","volume":"18","author":"Sethi","year":"2009","journal-title":"Eur Spine J"},{"key":"R19-8-20210204","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1227\/00006123-198811000-00014","article-title":"Relief of lumbar canal stenosis using multilevel subarticular fenestrations as an alternative to wide laminectomy: preliminary report.","volume":"23","author":"Young","year":"1988","journal-title":"Neurosurgery"},{"key":"R20-8-20210204","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1007\/BF01808872","article-title":". Unilateral laminotomy for bilateral decompression of lumbar spinal stenosis. Part i: anatomical and surgical considerations.","volume":"139","author":"Spetzger","year":"1997","journal-title":"Acta Neurochir"},{"key":"R21-8-20210204","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/BF01808874","article-title":". Unilateral laminotomy for bilateral decompression of lumbar spinal stenosis. Part ii: clinical experiences.","volume":"139","author":"Spetzger","year":"1997","journal-title":"Acta Neurochir"},{"key":"R22-8-20210204","doi-asserted-by":"crossref","first-page":"E172","DOI":"10.1097\/BRS.0b013e3181db998c","article-title":". A comparison of unilateral and bilateral laminotomies for decompression of l4-l5 spinal stenosis.","volume":"36","author":"Hong","year":"2011","journal-title":"Spine"},{"key":"R23-8-20210204","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1227\/00006123-199508000-00025","article-title":"Central lumbar stenosis caused by ligamentum flavum: Unilateral laminotomy for bilateral ligamentectomy: preliminary report of two cases.","volume":"37","author":"Poletti","year":"1995","journal-title":"Neurosurgery"},{"key":"R24-8-20210204","doi-asserted-by":"crossref","first-page":"2268","DOI":"10.1097\/00007632-199911010-00016","article-title":". Microdecompression for lumbar spinal canal stenosis.","volume":"24","author":"Weiner","year":"1999","journal-title":"Spine"},{"key":"R25-8-20210204","doi-asserted-by":"crossref","first-page":"579","DOI":"10.3171\/SPI-07\/12\/579","article-title":". Degenerative lumbar spinal stenosis: analysis of results in a series of 374 patients treated with unilateral laminotomy for bilateral microdecompression.","volume":"7","author":"Costa","year":"2007","journal-title":"J Neurosurg Spine"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000000042","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T23:16:26Z","timestamp":1620947786000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201602000-00008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000042","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2016,2]]}}}