{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T17:59:47Z","timestamp":1782755987619,"version":"3.54.5"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>A retrospective study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The aim of this study was the evaluation of the safety and effectiveness of radiofrequency-targeted vertebral augmentation (RF-TVA) in comparison with balloon kyphoplasty (BK) for the treatment of acute painful vertebral compression fractures (VCFs) on the basis of matched pairs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background:<\/jats:title>\n            <jats:p>Vertebroplasty and BK are the common surgical interventions for the treatment of VCF. Both are effective and safe but pose some risks such as adjacent fractures and cement leakage. In 2009, RF-TVA was introduced as an innovative augmentation procedure for the treatment of VCF.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>A total of 192 patients (116 female; 51\u201390 y) with VCF (n=303) at 1 to 3 levels were treated with RF-TVA or BK. Functionality (Oswestry Disability Index), pain (visual analogue scale), vertebral height (anterior, middle), and kyphotic angle were evaluated over a 2-year period (postoperatively, 3\u20134 d, 3, 6, 12, and 24 mo). In addition, operating time and occurrence of cement leakage were recorded.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Pain and functionality were significantly improved after both treatments. In both groups, there was an increase in the vertebral height and a decrease in the kyphotic angle, which remained relatively consistent during 24 months. The incidence of cement leakage was 9.4% (n=9) in the RF-TVA group and 24.0% (n=25) in the BK group. The mean operating time with radiofrequency kyphoplasty was 25.9\u00b19.9 minutes, and with balloon kyphoplasty 48.0\u00b118.4 minutes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>RF-TVA is a safe and effective procedure for the treatment of vertebral compression fractures when compared with BK. Improvement in pain and functional scores after RF-TVA are durable through 24 months postprocedure and remained better than those after BK at long-term follow-up. Operating time for RF-TVA is shorter and the risk of cement leakage is lower. Both procedures provided similar results in vertebral height restoration and reduction in the kyphotic angle.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000050","type":"journal-article","created":{"date-parts":[[2013,11,18]],"date-time":"2013-11-18T21:02:42Z","timestamp":1384808562000},"page":"E247-E251","source":"Crossref","is-referenced-by-count":12,"title":["Comparison of Radiofrequency-targeted Vertebral Augmentation With Balloon Kyphoplasty for the Treatment of Vertebral Compression Fractures"],"prefix":"10.1097","volume":"30","author":[{"given":"Rahel","family":"Bornemann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom R.","family":"Jansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koroush","family":"Kabir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter H.","family":"Pennekamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brit","family":"St\u00fcwe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dieter C.","family":"Wirtz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Pflugmacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230831","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1055\/s-0028-1103000","article-title":"Osteoporotic Vertebral Compression Fractures and Vertebral Augmentation","volume":"25","author":"Kondo","year":"2008","journal-title":"Semin Intervent Radio"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s12178-007-9013-0","article-title":"Vertebroplasty and kyphoplasty: a comparative review of efficacy and adverse events","volume":"1","author":"McCall","year":"2008","journal-title":"Curr Rev Musculoskelet Med"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1007\/s00586-012-2148-8","article-title":"Continuing conservative care versus crossover to radiofrequency kyphoplasty: a comparative effectiveness study on the treatment of vertebral compression fractures","volume":"21","author":"Bornemann","year":"2012","journal-title":"Eur Spine J"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1007\/s00586-008-0701-2","article-title":"Balloon kyphoplasty in the treatment of metastatic disease of the spine: a 2-year prospective evaluation","volume":"17","author":"Pflugmacher","year":"2008","journal-title":"Eur Spine J"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/1749-799X-6-43","article-title":"Kyphoplasty in osteoporotic vertebral compression fractures\u2014Guidelines and technical considerations","volume":"6","author":"Robinson","year":"2011","journal-title":"J Ortho Surg Res"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/978-3-211-99370-5_29","article-title":"Precutaneous Vertebral Augmentation: StabiliTTM a new delivery system for vertebral fractures","volume":"108","author":"Robertson","year":"2011","journal-title":"Acta Neurochir Suppl"},{"key":"R7-20230831","first-page":"1","article-title":"DFine radiofrequency kyphoplasty (RFK) - kyphoplasty with ultrahigh viscosity cement","volume":"182","author":"Elgeti","year":"2010","journal-title":"R\u00f6F\u00f6"},{"key":"R8-20230831","first-page":"13","article-title":"Radiofrequency kyphoplasty\u2014an innovative method of treating osteoporotic vertebral body compression fractures","volume":"18","author":"Drees","year":"2011","journal-title":"J Miner Stoffwechs"},{"key":"R9-20230831","first-page":"174","article-title":"Radiofrequency kyphoplasty\u2014a novel vertebral augmentation system","volume":"3","author":"Kurth","year":"2012","journal-title":"Osteologie"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1055\/s-0031-1280122","article-title":"Comparison of clinical and radiological data in the treatment of patients with osteoporotic vertebral compression fractures using radiofrequency kyphoplasty or balloon kyphoplasty","volume":"150","author":"Pflugmacher","year":"2012","journal-title":"Z Orthop Unfall"},{"key":"R11-20230831","first-page":"525","article-title":"Radiofrequency-targeted vertebral augmentation versus traditional balloon kyphoplasty: radiographic and morphologic outcomes of an ex vivo biomechanical pilot study","volume":"7","author":"Dalton","year":"2012","journal-title":"Clin Interv Aging"},{"key":"R12-20230831","first-page":"5","article-title":"Radiofrequency kyphoplasty for the treatment of osteoporotic and neoplastic vertebral body fractures","volume":"18","author":"Elgeti","year":"2011","journal-title":"J Miner Stoffwechs"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s00198-009-0952-8","article-title":"Balloon kyphoplasty versus vertebroplasty for the treatment of osteoporotic vertebral compression fracture: a prospective, comparative, and randomized clinical study","volume":"21","author":"Liu","year":"2010","journal-title":"Osteoporosis International"},{"key":"R14-20230831","first-page":"381","article-title":"Long-term efficacy and safety of balloon kyphoplasty for treatment of osteoporotic vertebral fractures","volume":"150","author":"Bornemann","year":"2012","journal-title":"Z Orthop Unfall"},{"key":"R15-20230831","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/1754-9493-2-2","article-title":"Complications and safety aspects of kyphoplasty for osteoporotic vertebral compression fractures: a prospective follow-up study in 102 consecutive patients","volume":"2","author":"Robinson","year":"2008","journal-title":"Patient Saf Surg"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1016\/S0140-6736(09)60010-6","article-title":"Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): a randomised controlled trial","volume":"373","author":"Wardlaw","year":"2009","journal-title":"Lancet"},{"key":"R17-20230831","doi-asserted-by":"crossref","first-page":"1880","DOI":"10.1007\/s00586-012-2262-7","article-title":"Social implications of balloon kyphoplasty: prospective study from a single UK centre","volume":"21","author":"Klezl","year":"2012","journal-title":"Eur Spine J"},{"key":"R18-20230831","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1002\/jbmr.364","article-title":"Balloon kyphoplasty for the treatment of acute vertebral compression fractures: 2-year results from a randomized trial","volume":"26","author":"Boonen","year":"2011","journal-title":"J Bone Miner Res"},{"key":"R19-20230831","first-page":"156","article-title":"Is height restoration possible with a comparatively smaller amount of cement in radiofrequency kyphoplasty using a monopedicle approach","volume":"151","author":"R\u00f6llinghoff","year":"2013","journal-title":"Z Orthop Unfall"},{"key":"R20-20230831","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1080\/10255842.2010.522183","article-title":"Mechanical variables affecting balloon kyphoplasty outcome\u2014a finite element study","volume":"15","author":"Dabirrahmani","year":"2012","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R21-20230831","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1007\/s00586-005-0048-x","article-title":"Efficacy and safety of balloon kyphoplasty in the treatment of vertebral compression fractures: a systemic review","volume":"15","author":"Bouza","year":"2006","journal-title":"Eur Spine J"},{"key":"R22-20230831","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.spinee.2006.10.020","article-title":"Percutaneous vertebral augmentation: an elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty","volume":"7","author":"Frankel","year":"2007","journal-title":"Spine J"},{"key":"R23-20230831","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1007\/s00586-007-0308-z","article-title":"Balloon kyphoplasty in the management of vertebral compression fractures: an updated systematic review and meta-analysis","volume":"16","author":"Taylor","year":"2007","journal-title":"Eur Spine J"},{"key":"R24-20230831","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1097\/BRS.0b013e3181a18529","article-title":"Computer navigation in balloon kyphoplasty reduce the intraoperative radiation exposure","volume":"34","author":"Izadpaha","year":"2009","journal-title":"Spine"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201704000-00025","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T18:34:18Z","timestamp":1693506858000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201704000-00025"}},"subtitle":["2-Year Results"],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000050","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2017,4]]}}}