{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,12,21]],"date-time":"2023-12-21T17:21:15Z","timestamp":1703179275086},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>A retrospective study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To evaluate radiographic changes of patients with osteophytes at the anterior border of the caudal vertebral body who were treated with anterior cervical discectomy and fusion using dynamic rotational plates.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Dynamic cervical plates are widely used in surgeries of the anterior cervical spine. One concern in using dynamic plates is that the subjacent anterior osteophytes might act as a bony block and prevent dynamization of the plate. To our knowledge, there are no studies that have investigated the validity of this concern.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>Twenty-eight patients were selected for the study out of patients who had undergone 1-level anterior cervical discectomy and fusion using a dynamic rotational plate. They were divided into 2 groups on the basis of the presence of osteophytes located at the anterior border of the subjacent vertebrae. Thirteen patients had osteophytes and 15 control patients did not. The mean follow-up period was 10.8\u00b18.4 months (range, 6\u201336 mo). Lateral radiographs were taken preoperatively, immediately postoperatively, and at the final follow-ups to assess changes in the following radiographic parameters: Cobb angle of the adjacent segments and fused segment, horizontal distance between C2 and C7 plumb lines, height of the bone graft, vertebral heights of the operated segment, and migration distance of the plate.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>No statistical significance was found in the Cobb angles of the adjacent segments and fused segment, distance between the C2\u2013C7 plumb lines, height of the graft, height of vertebral bodies of the operated segment, and migration distance of the plate through the preoperative, postoperative, and final follow-ups between the 2 groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Osteophytes did not appear to affect the dynamization of plates in any of the measured radiographic parameters.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000064","type":"journal-article","created":{"date-parts":[[2013,12,12]],"date-time":"2013-12-12T09:27:04Z","timestamp":1386840424000},"page":"E314-E318","source":"Crossref","is-referenced-by-count":1,"title":["Do Anterior Cervical Osteophytes Prevent Dynamization of Cervical Dynamic Plates?"],"prefix":"10.1097","volume":"29","author":[{"given":"Moon Soo","family":"Park","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seong-Hwan","family":"Moon","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hwan-Mo","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seok Woo","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tae-Hwan","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seul Ki","family":"Min","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo-Kyung","family":"Suh","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K. Daniel","family":"Riew","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, MO"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230831","first-page":"1566","article-title":"Anterior cervical fixation: analysis of load-sharing and stability with use of static and dynamic plates","volume":"88","author":"Brodke","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1007\/s00586-007-0451-6","article-title":"Fusion and failure following anterior cervical plating with dynamic or rigid plates: 6-months results of a multi-centric, prospective, randomized, controlled study","volume":"16","author":"Stulik","year":"2007","journal-title":"Eur Spine J"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.spinee.2007.11.009","article-title":"Choice of plate may affect outcomes for single versus multilevel ACDF: results of a prospective randomized single-blind trial","volume":"9","author":"Nunley","year":"2009","journal-title":"Spine J"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.spinee.2006.07.004","article-title":"Static versus dynamic plating for multilevel anterior cervical discectomy and fusion","volume":"7","author":"DuBois","year":"2007","journal-title":"Spine J"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BSD.0b013e31819877e7","article-title":"A comparison of fixed-hole and slotted-hole dynamic plates for anterior cervical discectomy and fusion","volume":"23","author":"Hong","year":"2010","journal-title":"J Spinal Disord Tech"},{"issue":"suppl 3","key":"R6-20230831","first-page":"264","article-title":"Clinical and radiological evaluation of the Codman semiconstrained load-sharing anterior cervical plate: prospective multicenter trial and independent blinded evaluation of outcome","volume":"99","author":"Casha","year":"2003","journal-title":"J Neurosurg"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"E582","DOI":"10.1097\/BRS.0b013e3181e0f06a","article-title":"Risk factors for early reconstruction failure of multilevel cervical corpectomy with dynamic plate fixation","volume":"36","author":"Okawa","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.spinee.2010.08.031","article-title":"The use of the T1 sagittal angle in predicting overall sagittal balance of the spine","volume":"10","author":"Knott","year":"2010","journal-title":"Spine J"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"104","DOI":"10.3171\/spi.2007.6.2.104","article-title":"Neutral upright sagittal spinal alignment from the occiput to the pelvis in asymptomatic adults: a review and resynthesis of the literature","volume":"6","author":"Kuntz","year":"2007","journal-title":"J Neurosurg Spine"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1038\/sj.sc.3101418","article-title":"Anterior cervical dynamic ABC plating with single level corpectomy and fusion in forty-two patients","volume":"41","author":"Epstein","year":"2003","journal-title":"Spinal Cord"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1097\/BRS.0b013e318198ce10","article-title":"Implant complications, fusion, loss of lordosis, and outcome after anterior cervical plating with dynamic or rigid plates: two-year results of a multi-centric, randomized, controlled study","volume":"34","author":"Pitzen","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1097\/BRS.0b013e3181a99346","article-title":"Dynamic plates in anterior cervical fusion surgery: graft settling and cervical alignment","volume":"34","author":"Ghahreman","year":"2009","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201607000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T18:17:21Z","timestamp":1693505841000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201607000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":12,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000064","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]}}}