{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T09:17:07Z","timestamp":1693559827475},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>An in vitro biomechanical study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The aim of this study was to determine the effect of an optional sleeve on height restoration and compare it with the fracture reduction achieved by a commercially available inflatable bone tamp under simulated physiological load (110 N).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Loss of reduction after bone tamp deflation before cement injection still remains a concern. The optional sleeve surrounds the bone tamp to help maintain height during the kyphoplasty procedure while filling the created cavity with bone cement on the contralateral side.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Eighteen osteoporotic vertebral bodies (VBs) (T11\u2013L4) were alternately assigned to 1 of the 2 treatment groups: group A: KYPHON (Kyphon Inc.) and group B: AFFIRM with sleeve (Globus Medical Inc.). The VBs were compressed axially at a rate of 5 mm\/min until compressed to 40% of the initial anterior height. The fractured VBs then underwent kyphoplasty with cement augmentation while still maintaining load (110 N). The augmented VBs were then recompressed and anterior VB height (mm) and wedge angle (degrees) were measured initially after mechanically creating an anterior wedge fracture, and after repairing the compression fracture. The effect of kyphoplasty on vertebral height, kyphotic angle, cement volumes, and inflation pressures were compared between the treatment groups. Failure load (N) data were compared between intact and repaired VBs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Average percentage of lost VB height restored in group A was 30%, compared with 56% for group B. The mean changes in wedge angle were similar to those of vertebral height measurements. No significant difference in mean inflation pressures (group A: 175\u00b137 psi; group B: 160\u00b136 psi) were found between the 2 groups. Average percentage increase in failure load was 241% and 212% in groups A and B, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Some height restoration was observed using the commercially available bone tamp in fractured VBs under simulated physiological load. The use of an outer sleeve significantly enhanced height restoration compared with the inflatable bone tamp alone.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000076","type":"journal-article","created":{"date-parts":[[2014,2,6]],"date-time":"2014-02-06T09:28:01Z","timestamp":1391678881000},"page":"E211-E218","source":"Crossref","is-referenced-by-count":1,"title":["Effect of an Outer Sleeve on an Inflatable Balloon Tamp in Terms of Height Restoration Under Simulated Physiological Load"],"prefix":"10.1097","volume":"30","author":[{"given":"Walter C.","family":"Peppelman","sequence":"first","affiliation":[{"name":"Pennsylvania Spine Institute, Harrisburg, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"Beutler","sequence":"additional","affiliation":[{"name":"Pennsylvania Spine Institute, Harrisburg, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Gordon","sequence":"additional","affiliation":[{"name":"Newport Orthopedic Institutes, Newport Beach, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suresh R.","family":"Chintakunta","sequence":"additional","affiliation":[{"name":"Globus Medical Inc., Audubon, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Damien","family":"O\u2019Halloran","sequence":"additional","affiliation":[{"name":"Globus Medical Inc., Audubon, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brandon","family":"Bucklen","sequence":"additional","affiliation":[{"name":"Globus Medical Inc., Audubon, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230831","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1007\/s00586-010-1341-x","article-title":"Vertebral body stenting: a new method for vertebral augmentation versus kyphoplasty","volume":"19","author":"Rotter","year":"2010","journal-title":"Eur Spine J"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1097\/00007632-200208010-00009","article-title":"An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load","volume":"27","author":"Belkoff","year":"2002","journal-title":"Spine"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/00007632-200101150-00008","article-title":"An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture","volume":"26","author":"Belkoff","year":"2001","journal-title":"Spine"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1148\/radiol.2373041654","article-title":"Kyphoplasty versus vertebroplasty to increase vertebral body height: a cadaveric study","volume":"237","author":"Hiwatashi","year":"2005","journal-title":"Radiology"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1007\/s00264-011-1283-x","article-title":"Percutaneous vertebroplasty versus balloon kyphoplasty for treatment of osteoporotic vertebral compression fracture: a meta-analysis of randomised and non-randomised controlled trials","volume":"35","author":"Han","year":"2011","journal-title":"Int Orthop"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"2915","DOI":"10.1007\/s00198-011-1639-5","article-title":"Balloon kyphoplasty and vertebroplasty in the management of vertebral compression fractures","volume":"22","author":"Boonen","year":"2011","journal-title":"Osteoporos Int"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.3171\/foc.2005.18.3.6","article-title":"Immediate and early postoperative pain relief after kyphoplasty without significant restoration of vertebral body height in acute osteoporotic vertebral fractures","volume":"18","author":"Feltes","year":"2005","journal-title":"Neurosurg Focus"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"2806","DOI":"10.1097\/01.brs.0000190885.85675.a0","article-title":"Balloon kyphoplasty is effective in deformity correction of osteoporotic vertebral compression fractures","volume":"30","author":"Voggenreiter","year":"2005","journal-title":"Spine"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"1783","DOI":"10.1097\/BRS.0b013e3181b7cc5d","article-title":"Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures","volume":"35","author":"Upasani","year":"2010","journal-title":"Spine"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"2468","DOI":"10.1097\/00007632-199912010-00008","article-title":"In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems","volume":"24","author":"Sato","year":"1999","journal-title":"Spine"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","article-title":"New in vivo measurements of pressures in the intervertebral disc in daily life","volume":"24","author":"Wilke","year":"1999","journal-title":"Spine"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1097\/00007632-200107150-00026","article-title":"Initial outcome and efficacy of \u201ckyphoplasty\u201d in the treatment of painful osteoporotic vertebral compression fractures","volume":"26","author":"Lieberman","year":"2001","journal-title":"Spine"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/00007632-200001150-00004","article-title":"Effect of augmentation on the mechanics of vertebral wedge fractures","volume":"25","author":"Wilson","year":"2000","journal-title":"Spine"},{"key":"R14-20230831","first-page":"1893","article-title":"Kyphosis correction and height restoration effects of percutaneous vertebroplasty","volume":"24","author":"Teng","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"R15-20230831","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1359\/jbmr.2003.18.1.24","article-title":"The dynamic mobility of vertebral compression fractures","volume":"18","author":"McKiernan","year":"2003","journal-title":"J Bone Miner Res"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1148\/radiol.2333030400","article-title":"Osteoporotic vertebral collapse: percutaneous vertebroplasty and local kyphosis correction","volume":"233","author":"Carlier","year":"2004","journal-title":"Radiology"},{"key":"R17-20230831","doi-asserted-by":"crossref","first-page":"1772","DOI":"10.1097\/00007632-199909010-00004","article-title":"Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures","volume":"24","author":"Tohmeh","year":"1999","journal-title":"Spine"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201704000-00020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T18:33:15Z","timestamp":1693506795000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201704000-00020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000076","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2017,4]]}}}