{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T02:20:55Z","timestamp":1781144455707,"version":"3.54.1"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>The risk factors for cement leakage were retrospectively reviewed in 192 patients who underwent percutaneous vertebral augmentation (PVA).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To discuss the factors related to the cement leakage in PVA procedure for the treatment of osteoporotic vertebral compression fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>PVA is widely applied for the treatment of osteoporotic vertebral fractures. Cement leakage is a major complication of this procedure. The risk factors for cement leakage were controversial.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>A retrospective review of 192 patients who underwent PVA was conducted. The following data were recorded: age, sex, bone density, number of fractured vertebrae before surgery, number of treated vertebrae, severity of the treated vertebrae, operative approach, volume of injected bone cement, preoperative vertebral compression ratio, preoperative local kyphosis angle, intraosseous clefts, preoperative vertebral cortical bone defect, and ratio and type of cement leakage. To study the correlation between each factor and cement leakage ratio, bivariate regression analysis was employed to perform univariate analysis, whereas multivariate linear regression analysis was employed to perform multivariate analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The study included 192 patients (282 treated vertebrae), and cement leakage occurred in 100 vertebrae (35.46%). The vertebrae with preoperative cortical bone defects generally exhibited higher cement leakage ratio, and the leakage is typically type C. Vertebrae with intact cortical bones before the procedure tend to experience type S leakage. Univariate analysis showed that patient age, bone density, number of fractured vertebrae before surgery, and vertebral cortical bone were associated with cement leakage ratio (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.05). Multivariate analysis showed that the main factors influencing bone cement leakage are bone density and vertebral cortical bone defect, with standardized partial regression coefficients of \u22120.085 and 0.144, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>High bone density and vertebral cortical bone defect are independent risk factors associated with bone cement leakage.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000229","type":"journal-article","created":{"date-parts":[[2014,12,3]],"date-time":"2014-12-03T13:39:00Z","timestamp":1417613940000},"page":"E171-E176","source":"Crossref","is-referenced-by-count":29,"title":["Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures"],"prefix":"10.1097","volume":"29","author":[{"given":"Weixing","family":"Xie","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daxiang","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinyong","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jixi","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuncong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"De","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230831","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.spinee.2007.04.004","article-title":"Comparison of vertebroplasty and balloon kyphoplasty for treatment of vertebral compression fractures: a meta-analysis of the literature","volume":"8","author":"Eck","year":"2008","journal-title":"Spine J"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1097\/BRS.0b013e3181a3c742","article-title":"Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications","volume":"34","author":"Lee","year":"2009","journal-title":"Spine"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"1983","DOI":"10.1097\/01.brs.0000229254.89952.6b","article-title":"Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies","volume":"31","author":"Hulme","year":"2006","journal-title":"Spine"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/jbmr.5650080915","article-title":"Vertebral fracture assessment using a semiquantitative technique","volume":"8","author":"Genant","year":"1993","journal-title":"J Bone Miner Res"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1302\/0301-620X.85B1.13026","article-title":"Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures","volume":"85","author":"Yeom","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"R6-20230831","first-page":"166","article-title":"Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty","volume":"33","author":"Galibert","year":"1987","journal-title":"Neurochirurgie"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"E419","DOI":"10.1097\/00007632-200210010-00022","article-title":"Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate","volume":"27","author":"Lee","year":"2002","journal-title":"Spine"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.2106\/00004623-200107000-00014","article-title":"Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate","volume":"83","author":"Harrington","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"R9-20230831","first-page":"175","article-title":"Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body","volume":"25","author":"Lin","year":"2004","journal-title":"AJNR Am J Neuroradiol"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"27","DOI":"10.3171\/spi.2005.2.1.0027","article-title":"Calcium phosphate cement leakage after percutaneous vertebroplasty for osteoporotic vertebral fractures: risk factor analysis for cement leakage","volume":"2","author":"Nakano","year":"2005","journal-title":"J Neurosurg Spine"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.2214\/AJR.06.0903","article-title":"Cement leakage during vertebroplasty can be predicted on preoperative MRI","volume":"188","author":"Hiwatashi","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"W442","DOI":"10.2214\/AJR.09.2774","article-title":"Cement leakage in percutaneous vertebroplasty for osteoporotic compression fractures with or without intravertebral clefts","volume":"193","author":"Tanigawa","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/j.spinee.2011.07.027","article-title":"Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors","volume":"11","author":"Nieuwenhuijse","year":"2011","journal-title":"Spine J"},{"key":"R14-20230831","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1148\/radiol.2511080854","article-title":"Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors","volume":"251","author":"Kim","year":"2009","journal-title":"Radiology"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201605000-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T18:20:41Z","timestamp":1693506041000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201605000-00009"}},"subtitle":["Analysis of Risk Factors"],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":14,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000229","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]}}}