{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T13:34:12Z","timestamp":1773149652654,"version":"3.50.1"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>Retrospective cohort study comparing intraobserver and interobserver reliability of 3 different radiologic fusion classifications following uninstrumented single-level anterior lumbar interbody fusion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective of the Study:<\/jats:title>\n            <jats:p>The objective of the study was to compare the intraobserver and interobserver reliability of 3 different radiologic spinal fusion scoring systems.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Knowledge regarding radiologic spinal fusion is crucial when studying patients that were treated with lumbar interbody fusion. The scoring system should be reliable and reproducible. Various radiologic classification systems coexist, but the reliability of these systems has thus far not been compared in a single consecutive group of patients. The aim of the present study was the identification of the most valid scoring system in the assessment of interbody fusion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We studied a retrospective consecutive cohort of 50 patients who underwent an anterior lumbar interbody fusion procedure by a single surgeon using a stand-alone cage performed between 1993 and 2002. Plain anterior-posterior, lateral radiographs, and flexion-extension radiographs were made during follow-up visits and were used for analysis. The interbody fusion was scored on these radiographic images using the 3 classification systems (Brantigan, Burkus, and the Radiographic Score) by 2 experienced musculoskeletal radiologists and 2 senior orthopedic spinal surgeons all of whom were blinded to clinical data and outcome.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of the 3 classifications included in the current study, the Burkus classification had a moderate interobserver agreement and a substantial to perfect intraobserver agreement. The other classifications (Bratingan and the Radiographic Score) showed only fair interobserver agreement and moderate to substantial agreement among all observers. No significant differences in reliability between orthopedic surgeons and radiologists were found for all 3 classifications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The Burkus classification system was classified as most reliable in this, but showed only moderate interobserver agreement. Therefore, the need for a more reliable classification system for the radiographic assessment of lumbar interbody fusion still exists to date.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000423","type":"journal-article","created":{"date-parts":[[2018,3,30]],"date-time":"2018-03-30T13:11:52Z","timestamp":1522415512000},"page":"E853-E856","source":"Crossref","is-referenced-by-count":6,"title":["Interobserver and Intraobserver Reliability in the Radiologic Assessment of Lumbar Interbody Fusion"],"prefix":"10.1097","volume":"30","author":[{"given":"Robert J.","family":"Kroeze","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Medisch Centrum Alkmaar, Alkmaar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Harm C.A.","family":"Graat","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medisch Centrum Alkmaar, Alkmaar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Winand J.","family":"Pluymakers","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medisch Centrum Alkmaar, Alkmaar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Louis N.","family":"Marting","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Antonius Ziekenhuis, Nieuwegein"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martijn","family":"van Dijk","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Antonius Ziekenhuis, Nieuwegein"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cees F.","family":"van Dijke","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medisch Centrum Alkmaar, Alkmaar, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anton H.","family":"vd Klis","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medisch Centrum Alkmaar, Alkmaar, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven J.","family":"Verberne","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medisch Centrum Alkmaar, Alkmaar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert J.","family":"de Gruyter","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medisch Centrum Alkmaar, Alkmaar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier P.P.","family":"Temmerman","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medisch Centrum Alkmaar, Alkmaar"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"suppl","key":"R1-20230831","first-page":"126S","article-title":"The treatment of degenerative lumbar disorders: a critical review of the literature","volume":"20","author":"Z","year":"1995","journal-title":"Spine (Phila Pa 1976)"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"2731","DOI":"10.1007\/s00586-013-3003-2","article-title":"Relation between radiological assessment and biomechanical stability of lumbar interbody fusion in a large animal model","volume":"22","author":"Kroeze","year":"2013","journal-title":"Eur Spine J"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"859","DOI":"10.2106\/00004623-199906000-00014","article-title":"Interbody fusion cages in reconstructive operations on the spine","volume":"81","author":"McAfee","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.spinee.2004.06.021","article-title":"Three- to six-year follow-up of stand-alone BAK cages implanted by a single surgeon","volume":"5","author":"Button","year":"2005","journal-title":"Spine J"},{"issue":"suppl 1","key":"R5-20230831","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.1097\/00007632-200208151-00007","article-title":"Overview of the biology of lumbar spine fusion and principles for selecting a bone graft substitute","volume":"27","author":"Boden","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"E1564","DOI":"10.1097\/BRS.0b013e3181ef5c14","article-title":"A multicenter study to evaluate the safety and efficacy of a stand-alone anterior carbon I\/F Cage for anterior lumbar interbody fusion: two-year results from a Food and Drug Administration investigational device exemption clinical trial","volume":"35","author":"Li","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/foc.2001.10.4.12","article-title":"Surgical Interbody Research Group: radiographic assessment of interbody fusion devices: fusion criteria for anterior lumbar interbody surgery","volume":"10","author":"Burkus","year":"2001","journal-title":"Neurosurg Focus"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"2106","DOI":"10.1097\/00007632-199310001-00030","article-title":"A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients","volume":"18","author":"Brantigan","year":"1993","journal-title":"Spine"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1097\/00007632-200204010-00003","article-title":"The effect of cage stiffness on the rate of lumbar interbody fusion: an in vivo model using poly(l-lactic Acid) and titanium cages","volume":"27","author":"van Dijk","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"653","DOI":"10.3171\/spi.2005.2.6.0653","article-title":"Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 4: radiographic assessment of fusion","volume":"2","author":"Resnick","year":"2005","journal-title":"J Neurosurg Spine"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1097\/00007632-200006010-00017","article-title":"Lumbar interbody fusion using the Brantigan I\/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: two-year results from a Food and Drug Administration investigational device exemption clinical trial","volume":"25","author":"Brantigan","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.jclinepi.2005.10.015","article-title":"When to use agreement versus reliability measures","volume":"59","author":"de Vet","year":"2006","journal-title":"J Clin Epidemiol"},{"issue":"suppl","key":"R13-20230831","doi-asserted-by":"crossref","first-page":"S261","DOI":"10.1097\/00007632-199106001-00017","article-title":"Correlation of radiologic assessment of lumbar spine fusions with surgical exploration","volume":"16","author":"Brodsky","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"key":"R14-20230831","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1016\/j.spinee.2007.12.004","article-title":"Reliability and accuracy of fine-cut computed tomography scans to determine the status of anterior interbody fusions with metallic cages","volume":"8","author":"Carreon","year":"2008","journal-title":"Spine J"},{"key":"R15-20230831","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1016\/j.spinee.2007.03.013","article-title":"Fusion assessment of posterior lumbar interbody fusion using radiolucent cages: X-ray films and helical computed tomography scans compared with surgical exploration of fusion","volume":"8","author":"Fogel","year":"2008","journal-title":"Spine J"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1097\/01.BRS.0000061988.93175.74","article-title":"Radiologic assessment of interbody fusion using carbon fiber cages","volume":"28","author":"Santos","year":"2003","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201707000-00036","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T19:09:48Z","timestamp":1693508988000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201707000-00036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000423","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2017,7]]}}}