{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T17:00:27Z","timestamp":1793120427924,"version":"4.5.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>This study was a retrospective radiographic analysis of consecutive patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To analyze exposure to radiation of the surgeon and\u2014separately\u2014of patients in minimally invasive surgery (MIS) of multilevel posterior stabilization by percutaneous pedicle screw insertion guided by navigation (PIN) versus percutaneous pedicle screw insertion guided by fluoroscopy (PIF).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Spine surgeons are exposed to a 12-fold higher dose of radiation than other nonspinal musculoskeletal surgeons and PIF in MIS leads to a 2-fold higher dose of radiation than in open surgery. PIN might reduce the dose of radiation for the surgeon and the patient, especially in multilevel MIS surgery. To the best of our knowledge, there are only rare data of short-segment fusions that do not focus on exposure to radiation of surgeons.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>After power analysis, we included 205 consecutive screws (22 patients). We monitored dose of radiation (recorded separately for patient and surgeon), accuracy of screw placement, time of operation, and approach-related complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In PIN, only 58.7% of dose area product (cGy\u00d7cm<jats:sup>2<\/jats:sup>) per screw of PIF was determined for patients (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.01). The surgeon was only exposed to 19.9% of radiation per screw in PIN compared with dosage in PIF (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.01). Four of 205 screws (2.0%) were classified as being incorrectly positioned: 2 of 87 screws (2.3%) in PIF and 2 of 118 screws (1.7%) in PIN (<jats:italic toggle=\"yes\">P<\/jats:italic>&gt;0.05). We did not observe any wound infections.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>PIN in MIS is a safe procedure and does, compared with PIF, lead to significant reduction of radiation dose for patients and\u2014even more\u2014for spine surgeons.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000807","type":"journal-article","created":{"date-parts":[[2019,2,21]],"date-time":"2019-02-21T12:40:50Z","timestamp":1550752850000},"page":"E258-E265","source":"Crossref","is-referenced-by-count":17,"title":["Navigation Versus Fluoroscopy in Multilevel MIS Pedicle Screw Insertion"],"prefix":"10.1097","volume":"32","author":[{"given":"Markus R.","family":"Konieczny","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00fcdiger","family":"Krauspe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230831","doi-asserted-by":"crossref","first-page":"2637","DOI":"10.1097\/00007632-200010150-00016","article-title":"Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion","volume":"25","author":"Rampersaud","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"2811","DOI":"10.1007\/s00586-017-4968-z","article-title":"Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study","volume":"26","author":"Kaminski","year":"2017","journal-title":"Eur Spine J"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1007\/s00586-012-2505-7","article-title":"Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques","volume":"22","author":"Allam","year":"2013","journal-title":"Eur Spine J"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1007\/s00586-016-4489-1","article-title":"Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation","volume":"25","author":"Ohba","year":"2016","journal-title":"Eur Spine J"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/978-3-319-39546-3_42","article-title":"Does navigation improve pedicle screw placement accuracy? Comparison between navigated and non-navigated percutaneous and open fixations","volume":"124","author":"Innocenzi","year":"2017","journal-title":"Acta Neurochir Suppl"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1097\/BSD.0b013e31819877c8","article-title":"Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery","volume":"22","author":"Nakashima","year":"2009","journal-title":"J Spinal Disord Tech"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.neuchi.2015.04.002","article-title":"Assessment of the surgeon radiation exposure during a minimally invasive TLIF: comparison between fluoroscopy and O-arm system","volume":"61","author":"Grelat","year":"2015","journal-title":"Neurochirurgie"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.spinee.2006.12.012","article-title":"Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery","volume":"8","author":"Kim","year":"2008","journal-title":"Spine J"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"2055","DOI":"10.1097\/BRS.0b013e31825c05cd","article-title":"Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: perioperative results of a prospective, comparative, multicenter study","volume":"37","author":"Yang","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1227\/NEU.0b013e318222ae16","article-title":"Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing, part I: cervicothoracic spine","volume":"69","author":"Scheufler","year":"2011","journal-title":"Neurosurgery"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1007\/s005860050105","article-title":"Complications of vertebral metastasis surgery","volume":"7","author":"Pascal-Moussellard","year":"1998","journal-title":"Eur Spine J"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"1604","DOI":"10.1245\/s10434-014-4178-4","article-title":"Versatility of percutaneous pedicular screw fixation in metastatic spine tumor surgery: a prospective analysis","volume":"22","author":"Kumar","year":"2015","journal-title":"Ann Surg Oncol"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"2800","DOI":"10.1097\/01.brs.0000192297.07709.5d","article-title":"The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae","volume":"30","author":"Neo","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"R14-20230831","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1097\/BRS.0b013e3181646ba1","article-title":"Outcome-based classification for assessment of thoracic pedicular screw placement","volume":"33","author":"Upendra","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R15-20230831","doi-asserted-by":"crossref","first-page":"E1221","DOI":"10.1097\/BRS.0b013e3181e16ae2","article-title":"A novel classification system for spinal instability in neoplastic disease: an evidence-based approach and expert consensus from the Spine Oncology Study Group","volume":"35","author":"Fisher","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"175","DOI":"10.3758\/BF03193146","article-title":"G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences","volume":"39","author":"Faul","year":"2007","journal-title":"Behav Res Methods"},{"key":"R17-20230831","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","article-title":"Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses","volume":"41","author":"Faul","year":"2009","journal-title":"Behav Res Methods"},{"key":"R18-20230831","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1007\/s00586-012-2509-3","article-title":"CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws","volume":"22","author":"Waschke","year":"2013","journal-title":"Eur Spine J"},{"key":"R19-20230831","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1515\/BMT.2005.043","article-title":"Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation","volume":"50","author":"Seller","year":"2005","journal-title":"Biomed Tech (Berl)"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201906000-00014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T19:26:18Z","timestamp":1693509978000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201906000-00014"}},"subtitle":["Separate Analysis of Exposure to Radiation of the Surgeon and of the Patients"],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000807","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6]]}}}