{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T17:21:40Z","timestamp":1780507300630,"version":"3.54.1"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>This was a retrospective observatory analysis study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The objective of this study was to compare the differences in clinical and radiologic outcomes among patients who underwent anterior cervical corpectomy and fusion (ACCF) using titanium mesh cage (TMC) with end-caps and patients who underwent ACCF using TMC without end-cap.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>TMC has been widely used as an effective treatment option for ACCF. However, the subsidence of TMC has been observed frequently in the early postoperative period in some cases, resulting in related clinical complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>Patients who underwent single-level ACCF using TMC from September 2008 to June 2014 at our institute were retrospectively reviewed. Patients treated with TMC with end-cap were classified as an end-cap group, while patients treated with TMC without end-cap classified as a control group. The round press-fit\u2013type end-caps with 2.5-degree angulation were used at both ends of the cage for the end-cap group. Patients were followed postoperatively for a minimum of 36 months with radiologic evaluation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The subsidence was lower in the end-cap group (4.3\u00b13.6 vs. 4.8\u00b13.0, <jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.01), with lower rates of severe subsidence (\u22653\u2009mm) than the control group (34.2% vs. 52.1%, <jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.01). Visual analogue scale (VAS) scores for neck pain and Neck Disability Index (NDI) was reported significantly less in the study group, which showed a positive correlation with lesser severe subsidence. Also, the characteristics of subsidence differed between the 2 groups. In the end-cap group, slippage type subsidence occurred, resulting in better sagittal alignment than that in the control group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>For patients undergoing single-level ACCF, using TMC with end-cap provided better clinical results and similar fusion rate, compared with using TMC without end-cap. The end-cap decreased the severity of postoperative subsidence and related neck pain. Also, sagittal alignment was well preserved, suggesting it may contribute to cervical lordosis.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000000938","type":"journal-article","created":{"date-parts":[[2020,1,8]],"date-time":"2020-01-08T00:23:30Z","timestamp":1578443010000},"page":"E8-E13","source":"Crossref","is-referenced-by-count":27,"title":["Comparative Analysis of 2 Different Types of Titanium Mesh Cage for Single-level Anterior Cervical Corpectomy and Fusion in Terms of Postoperative Subsidence and Sagittal Alignment"],"prefix":"10.1097","volume":"33","author":[{"given":"Jung-Woo","family":"Hur","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyeong-Sik","family":"Ryu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Sung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ho-Jung","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myung-Soo","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,1,3]]},"reference":[{"issue":"suppl","key":"R1-20230831","first-page":"35","article-title":"Cervical corpectomy: report of 185 cases and review of the literature","volume":"90","author":"Eleraky","year":"1999","journal-title":"J Neurosurg"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/00002517-200008000-00009","article-title":"The management of one-level anterior cervical corpectomy with fusion using Atlantis hybrid plates: preliminary experience","volume":"13","author":"Epstein","year":"2000","journal-title":"J Spinal Disord"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"e5437","DOI":"10.1097\/MD.0000000000005437","article-title":"Anterior cervical discectomy and fusion versus anterior cervical corpectomy and fusion in multilevel cervical spondylotic myelopathy: a meta-analysis","volume":"95","author":"Wang","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1007\/s00586-017-5451-6","article-title":"Anterior cervical corpectomy and fusion versus posterior laminoplasty for the treatment of oppressive myelopathy owing to cervical ossification of posterior longitudinal ligament: a meta-analysis","volume":"27","author":"Qin","year":"2018","journal-title":"Eur Spine J"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"1877","DOI":"10.1007\/s00264-018-3804-3","article-title":"Anterior cervical corpectomy and fusion versus discectomy and fusion for the treatment of two-level cervical spondylotic myelopathy: analysis of sagittal balance and axial symptoms","volume":"42","author":"Zhang","year":"2018","journal-title":"Int Orthop"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1097\/BRS.0b013e318068b30a","article-title":"Cervical corpectomy with preserved posterior vertebral wall for cervical spondylotic myelopathy: a randomized control clinical study","volume":"32","author":"Ying","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/2016.3.FOCUS1638","article-title":"Complications following central corpectomy in 468 consecutive patients with degenerative cervical spine disease","volume":"40","author":"Sarkar","year":"2016","journal-title":"Neurosurg Focus"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/S1529-9430(02)00588-0","article-title":"Single stage anterior cervical reconstruction with titanium mesh cages, local bone graft, and anterior plating","volume":"3","author":"Thalgott","year":"2003","journal-title":"Spine J"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"26751","DOI":"10.1038\/srep26751","article-title":"Long-term results of anterior cervical corpectomy and fusion with nano-hydroxyapatite\/polyamide 66 strut for cervical spondylotic myelopathy","volume":"6","author":"Zhang","year":"2016","journal-title":"Sci Rep"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/BSD.0000000000000649","article-title":"Clinical comparison of surgical constructs for anterior cervical corpectomy and fusion in patients with cervical spondylotic myelopathy or ossified posterior longitudinal ligament: a systematic review and meta-analysis","volume":"31","author":"Niedzielak","year":"2018","journal-title":"Clin Spine Surg"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"E1239","DOI":"10.1097\/BSD.0000000000000428","article-title":"Graft subsidence and revision rates following anterior cervical corpectomy: a clinical study comparing different interbody cages","volume":"30","author":"Weber","year":"2017","journal-title":"Clin Spine Surg"},{"issue":"suppl","key":"R12-20230831","first-page":"172","article-title":"Titanium mesh cages for cervical spine stabilization after corpectomy: a clinical and radiological study","volume":"99","author":"Narotam","year":"2003","journal-title":"J Neurosurg"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1097\/01.BRS.0000058712.88053.13","article-title":"Effectiveness of titanium mesh cylindrical cages in anterior column reconstruction after thoracic and lumbar vertebral body resection","volume":"28","author":"Dvorak","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R14-20230831","doi-asserted-by":"crossref","first-page":"2891","DOI":"10.1007\/s00586-013-2976-1","article-title":"Evaluation of a new type of titanium mesh cage versus the traditional titanium mesh cage for single-level, anterior cervical corpectomy and fusion","volume":"22","author":"Yu","year":"2013","journal-title":"Eur Spine J"},{"key":"R15-20230831","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/01.bsd.0000210113.09521.aa","article-title":"Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy","volume":"19","author":"Nakase","year":"2006","journal-title":"J Spinal Disord Tech"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"E1088","DOI":"10.1097\/BRS.0000000000001557","article-title":"Multilevel corpectomy with anterior column reconstruction and plating for subaxial cervical osteomyelitis","volume":"41","author":"Theologis","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R17-20230831","doi-asserted-by":"crossref","first-page":"e9724","DOI":"10.1097\/MD.0000000000009724","article-title":"Anterior corpectomy and reconstruction using dynamic cervical plate and titanium mesh cage for cervical spondylotic myelopathy: a minimum 5-year follow-up study","volume":"97","author":"Zeng","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"R18-20230831","first-page":"111","article-title":"Preliminary surgical result of cervical spine reconstruction with a dynamic plate and titanium mesh cage","volume":"41","author":"Chung","year":"2006","journal-title":"J Korean Neurosurg Soc"},{"key":"R19-20230831","doi-asserted-by":"crossref","first-page":"E582","DOI":"10.1097\/BRS.0b013e3181e0f06a","article-title":"Risk factors for early reconstruction failure of multilevel cervical corpectomy with dynamic plate fixation","volume":"36","author":"Okawa","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R20-20230831","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00024720-200302000-00001","article-title":"Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating","volume":"16","author":"Hee","year":"2003","journal-title":"J Spinal Disord Tech"},{"key":"R21-20230831","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/01.bsd.0000210113.09521.aa","article-title":"Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical","volume":"19","author":"Nakase","year":"2006","journal-title":"J Spinal Disord Tech"},{"key":"R22-20230831","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1097\/01.brs.0000166526.78058.3c","article-title":"Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating","volume":"30","author":"Daubs","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"issue":"suppl","key":"R23-20230831","first-page":"186","article-title":"Graft subsidence after instrument-assisted anterior cervical fusion","volume":"97","author":"Tye","year":"2002","journal-title":"J Neurosurg"},{"key":"R24-20230831","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/00007632-200301150-00009","article-title":"Early reconstruction failures after multilevel cervical corpectomy","volume":"28","author":"Sasso","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R25-20230831","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1016\/j.jocn.2007.09.019","article-title":"Anterior cervical stabilization using a semi-constrained cervical plate and titanium mesh cage for single level corpectomy","volume":"15","author":"Lee","year":"2008","journal-title":"J Clin Neurosci"},{"key":"R26-20230831","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/01.blo.0000203446.06028.b5","article-title":"Postoperative infections in interbody fusion for degenerative spinal disease","volume":"444","author":"Pappou","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R27-20230831","first-page":"7405","article-title":"Anatomy-related risk factors for the subsidence of titanium mesh cage in cervical reconstruction after one-level corpectomy","volume":"8","author":"Wu","year":"2015","journal-title":"Int J Clin Exp Med"},{"key":"R28-20230831","first-page":"13","article-title":"Anterior correction of cervical kyphotic deformity: effects on myelopathy, neck pain, and sagittal alignment","volume":"100","author":"Ferch","year":"2004","journal-title":"J Neurosurg"},{"key":"R29-20230831","doi-asserted-by":"crossref","first-page":"739","DOI":"10.4184\/asj.2017.11.5.739","article-title":"Sagittal alignment of a strut graft affects graft subsidence and clinical outcomes of anterior cervical corpectomy and fusion","volume":"11","author":"Yamauchi","year":"2017","journal-title":"Asian Spine J"},{"key":"R30-20230831","doi-asserted-by":"crossref","first-page":"E703","DOI":"10.1097\/BRS.0000000000002468","article-title":"Long-term sustainability of functional improvement following central corpectomy for cervical spondylotic myelopathy and ossification of posterior longitudinal ligament","volume":"43","author":"Sarkar","year":"2018","journal-title":"Spine (Phila Pa 1976)"},{"key":"R31-20230831","doi-asserted-by":"crossref","first-page":"14414","DOI":"10.1038\/s41598-017-14300-4","article-title":"Prognostic value of lordosis decrease in radiographic adjacent segment pathology after anterior cervical corpectomy and fusion","volume":"7","author":"Liu","year":"2017","journal-title":"Sci Rep"},{"key":"R32-20230831","doi-asserted-by":"crossref","first-page":"5675","DOI":"10.12659\/MSM.907470","article-title":"Clinical efficacy of anterior partial corpectomy and titanium mesh fusion and internal fixation for treatment of old fracture dislocation of the lower cervical spine","volume":"23","author":"Miao","year":"2017","journal-title":"Med Sci Monit"},{"key":"R33-20230831","doi-asserted-by":"crossref","first-page":"156","DOI":"10.4184\/asj.2018.12.1.156","article-title":"Preventing construct subsidence following cervical corpectomy: the Bump-stop technique","volume":"12","author":"Shaw","year":"2018","journal-title":"Asian Spine J"},{"key":"R34-20230831","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1177\/230949900501300302","article-title":"Fusion rate of anterior cervical plating after corpectomy","volume":"13","author":"Cheng","year":"2005","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"suppl","key":"R35-20230831","first-page":"3","article-title":"Titanium cage reconstruction after cervical corpectomy","volume":"99","author":"Dorai","year":"2003","journal-title":"J Neurosurg"},{"key":"R36-20230831","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1016\/j.jocn.2014.02.016","article-title":"Effect of posterior subsidence on cervical alignment after anterior cervical corpectomy and reconstruction using titanium mesh cages in degenerative cervical disease","volume":"21","author":"Jang","year":"2014","journal-title":"J Clin Neurosci"},{"key":"R37-20230831","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1097\/00007632-200004010-00005","article-title":"Anterior cervical plating reverses load transfer through multilevel strut-grafts","volume":"25","author":"DiAngelo","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"R38-20230831","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1097\/00007632-199706010-00002","article-title":"Strength and stability of posterior lumbar interbody fusion. Comparison of titanium fiber mesh implant and tricortical bone graft","volume":"22","author":"Hoshijima","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"key":"R39-20230831","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/00002517-200002000-00002","article-title":"The value of anterior cervical plating in preventing vertebral fracture and graft extrusion after multilevel anterior cervical corpectomy with posterior wiring and fusion: indications, results, and complications","volume":"13","author":"Epstein","year":"2000","journal-title":"J Spinal Disord"},{"key":"R40-20230831","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00002517-200002000-00001","article-title":"Anterior cervical diskectomy and fusion without plate instrumentation in 178 patients","volume":"13","author":"Epstein","year":"2000","journal-title":"J Spinal Disord"},{"issue":"suppl","key":"R41-20230831","first-page":"8","article-title":"Anterior cervical arthrodesis using DOC dynamic stabilization implant for improvement in sagittal angulation and controlled settling","volume":"98","author":"Bose","year":"2003","journal-title":"J Neurosurg"},{"key":"R42-20230831","doi-asserted-by":"crossref","first-page":"2493","DOI":"10.1097\/01.brs.0000145412.93407.c3","article-title":"Results of surgical treatment for degenerative cervical myelopathy: anterior cervical corpectomy and stabilization","volume":"29","author":"Sevki","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R43-20230831","doi-asserted-by":"crossref","first-page":"e761","DOI":"10.1016\/j.wneu.2018.02.144","article-title":"Clinical effects of posterior longitudinal ligament removal and wide anterior cervical corpectomy for spondylosis","volume":"113","author":"Missori","year":"2018","journal-title":"World Neurosurg"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000000938","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T19:31:22Z","timestamp":1693510282000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000000938"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,3]]},"references-count":43,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000000938","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1,3]]}}}