{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T22:34:25Z","timestamp":1794954865777,"version":"4.9.1"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:sec><jats:title>Study Design:<\/jats:title><jats:p>Systematic review.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective:<\/jats:title><jats:p>To review the current clinical use of 3-dimensional printed (3DP) patient-specific implants in the spine.<\/jats:p><\/jats:sec><jats:sec><jats:title>Summary of Background Data:<\/jats:title><jats:p>Additive manufacturing is a transformative manufacturing method now being applied to spinal implants. Recent innovations in technology have allowed the production of medical-grade implants with unprecedented structure and customization, and the complex anatomy of the spine is ideally suited for patient-specific devices. Improvement in implant design through the process of 3DP may lead to improved osseointegration, lower subsidence rates, and faster operative times.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods:<\/jats:title><jats:p>A comprehensive search of the literature was conducted using Ovid MEDLINE, EMBASE, Scopus, and other sources that resulted in 1842 unique articles. All manuscripts describing the use of 3DP spinal implants in humans were included. Two independent reviewers (N.W. and N.E.S.) assessed eligibility for inclusion. The following outcomes were collected: pain score, Japanese Orthopedic Association (JOA) score, subsidence, fusion, Cobb angle, vertebral height, and complications. No conflicts of interest existed. No funding was received for this work.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>A total of 17 studies met inclusion criteria with a total of 35 patients. Only case series and case reports were identified. Follow-up times ranged from 3 to 36 months. Implant types included vertebral body replacement cages, interbody cages, sacral reconstruction prostheses, iliolumbar rods, and a posterior cervical plate. All studies reported improvement in both clinical and radiographic outcomes. 11 of 35 cases showed subsidence &gt;3\u2009mm, but only 1 case required a revision procedure. No migration, loosening, or pseudarthrosis occurred in any patient on the basis of computed tomography or flexion-extension radiographs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>Results of the systematic review indicate that 3DP technology is a viable means to fabricate patient-matched spinal implants. The effects on clinical and radiographic outcome measures are still in question, but these devices may produce favorable subsidence and pseudoarthrosis rates. Currently, the technology is ideally suited for complex tumor pathology and atypical bone defects. Future randomized controlled trials and cost analyses are still needed.<\/jats:p><jats:p>Level of Evidence: IV\u2014systematic review.<\/jats:p><\/jats:sec>","DOI":"10.1097\/bsd.0000000000001026","type":"journal-article","created":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T20:28:18Z","timestamp":1593548898000},"page":"400-407","source":"Crossref","is-referenced-by-count":70,"title":["3D-printed Patient-specific Spine Implants"],"prefix":"10.1097","volume":"33","author":[{"given":"Nicholas","family":"Wallace","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathaniel E.","family":"Schaffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ilyas S.","family":"Aleem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rakesh","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,6,16]]},"reference":[{"key":"R2-20231002","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3390\/ma10060672","article-title":"Additive Manufacturing Processes: selective laser melting, electron beam melting and binder jetting\u2014selection guidelines","volume":"10","author":"Gokuldoss","year":"2017","journal-title":"Materials (Basel)"},{"key":"R4-20231002","doi-asserted-by":"crossref","first-page":"2841","DOI":"10.1097\/01.brs.0000190886.56895.3d","article-title":"Biomodeling as an aid to spinal instrumentation","volume":"30","author":"D\u2019Urso","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"R5-20231002","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1097\/00007632-199906150-00013","article-title":"Spinal biomodeling","volume":"24","author":"D\u2019Urso","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"key":"R6-20231002","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1097\/bpo.0b013e3181594ced","article-title":"Rapid prototyping technology for surgeries of the pediatric spine and pelvis: benefits analysis","volume":"27","author":"Guarino","year":"2007","journal-title":"J Pediatr Orthop"},{"key":"R7-20231002","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1007\/s00586-010-1359-0","article-title":"Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study","volume":"19","author":"Mao","year":"2010","journal-title":"Eur Spine J"},{"key":"R8-20231002","doi-asserted-by":"crossref","first-page":"E1357","DOI":"10.1097\/BRS.0b013e3182a1f1bd","article-title":"Novel approach for the efficient use of a full-scale, 3-dimensional model for cervical posterior fixation: a technical case report","volume":"38","author":"Toyoda","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"R9-20231002","doi-asserted-by":"crossref","first-page":"3948","DOI":"10.12659\/MSM.895597","article-title":"Clinical use of 3D printing guide plate in posterior lumbar pedicle screw fixation","volume":"21","author":"Chen","year":"2015","journal-title":"Med Sci Monit"},{"key":"R10-20231002","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.spinee.2018.05.001","article-title":"Outcome and safety analysis of 3D-printed patient-specific pedicle screw jigs for complex spinal deformities: a comparative study","volume":"19","author":"Garg","year":"2019","journal-title":"Spine J"},{"key":"R11-20231002","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.12659\/MSM.900066","article-title":"A modified personalized image-based drill guide template for atlantoaxial pedicle screw placement: a clinical study","volume":"23","author":"Jiang","year":"2017","journal-title":"Med Sci Monit"},{"key":"R12-20231002","first-page":"11244","article-title":"Clinical application of 3D printing in pedicle screw fixation and fusion for the treatment of old type II odontoid fractures with posterior atlantoaxial dislocation","volume":"10","author":"Xiong","year":"2017","journal-title":"Int J Clin Exp Med"},{"key":"R13-20231002","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.wneu.2017.11.042","article-title":"Design and application of a novel patient-specific three-dimensional printed drill navigational guiding in atlantoaxial pedicle screw placement","volume":"114","author":"Pu","year":"2018","journal-title":"World Neurosurg"},{"key":"R14-20231002","article-title":"Levels of evidence for primary research","author":"Leopold","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"R15-20231002","article-title":"The oxford levels of evidence 2","author":"Howick","year":"2011","journal-title":"Oxford Cent Evidence-Based Med"},{"key":"R16-20231002","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1046\/j.1445-2197.2003.02748.x","article-title":"Methodological Index for Non-Randomized Studies (MINORS): development and validation of a new instrument","volume":"73","author":"Slim","year":"2003","journal-title":"ANZ J Surg"},{"key":"R17-20231002","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1016\/j.spinee.2018.01.019","article-title":"Vertebral body replacement using patient-specific three-dimensional-printed polymer implants in cervical spondylotic myelopathy: an encouraging preliminary report","volume":"18","author":"Amelot","year":"2018","journal-title":"Spine J"},{"key":"R18-20231002","doi-asserted-by":"crossref","first-page":"1032.e13","DOI":"10.1016\/j.wneu.2017.05.133","article-title":"Reconstruction of thoracic spine using a personalized 3D-printed vertebral body in adolescent with T9 primary bone tumor","volume":"105","author":"Choy","year":"2017","journal-title":"World Neurosurg"},{"key":"R19-20231002","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.wneu.2019.02.020","article-title":"Vertebral reconstruction with customized 3-dimensional\u2212printed spine implant replacing large vertebral defect with 3-year follow-up","volume":"126","author":"Chung","year":"2019","journal-title":"World Neurosurg"},{"key":"R20-20231002","doi-asserted-by":"crossref","first-page":"3073","DOI":"10.1007\/s00586-018-5708-8","article-title":"Biomimetic 3D-printed custom-made prosthesis for anterior column reconstruction in the thoracolumbar spine: a tailored option following en bloc resection for spinal tumors\u202f: Preliminary results on a case-series of 13 patients","volume":"27","author":"Girolami","year":"2018","journal-title":"Eur Spine J"},{"key":"R21-20231002","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1093\/ons\/opz077","article-title":"Customized \u201cwhole-cervical-vertebral-body\u201d reconstruction after modified subtotal spondylectomy of C2-C7 spinal tumor via piezoelectric surgery","volume":"17","author":"He","year":"2019","journal-title":"Oper Neurosurg (Hagerstown, Md)"},{"key":"R22-20231002","doi-asserted-by":"crossref","first-page":"453","DOI":"10.3349\/ymj.2017.58.2.453","article-title":"Sacral reconstruction with a 3D-printed implant after hemisacrectomy in a patient with sacral osteosarcoma: 1-year follow-up result","volume":"58","author":"Kim","year":"2017","journal-title":"Yonsei Med J"},{"key":"R23-20231002","doi-asserted-by":"crossref","first-page":"E1326","DOI":"10.1097\/BRS.0000000000002229","article-title":"Multilevel 3D printing implant for reconstructing cervical spine with metastatic papillary thyroid carcinoma","volume":"42","author":"Li","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"R24-20231002","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.wneu.2018.01.078","article-title":"L5 en-bloc vertebrectomy with customized reconstructive implant: comparison of patient-specific versus off-the-shelf implant","volume":"112","author":"Mobbs","year":"2018","journal-title":"World Neurosurg"},{"key":"R25-20231002","doi-asserted-by":"crossref","DOI":"10.1016\/j.wneu.2018.12.144","article-title":"Anterior lumbar interbody fusion using a personalized approach: is custom the future of implants for anterior lumbar interbody fusion surgery?","author":"Mobbs","year":"2019","journal-title":"World Neurosurg"},{"key":"R26-20231002","doi-asserted-by":"crossref","first-page":"513","DOI":"10.3171\/2016.9.SPINE16371","article-title":"The utility of 3D printing for surgical planning and patient-specific implant design for complex spinal pathologies: case report","volume":"26","author":"Mobbs","year":"2017","journal-title":"J Neurosurg Spine"},{"key":"R27-20231002","doi-asserted-by":"crossref","first-page":"314","DOI":"10.21037\/jss.2016.12.06","article-title":"Application of a 3D custom printed patient specific spinal implant for C1\/2 arthrodesis","volume":"2","author":"Phan","year":"2016","journal-title":"J Spine Surg (Hong Kong)"},{"key":"R28-20231002","doi-asserted-by":"crossref","first-page":"2239","DOI":"10.1007\/s00586-016-4473-9","article-title":"Surgical planning, manufacturing and implantation of an individualized cervical fusion titanium cage using patient-specific data","volume":"25","author":"Spetzger","year":"2016","journal-title":"Eur Spine J"},{"issue":"suppl 2","key":"R29-20231002","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1007\/s00586-018-5684-z","article-title":"Designing patient-specific solutions using biomodelling and 3D-printing for revision lumbar spine surgery","volume":"28","author":"Thayaparan","year":"2019","journal-title":"Eur Spine J"},{"key":"R30-20231002","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.wneu.2019.03.238","article-title":"Three-dimensional printing-assisted cervical anterior bilateral pedicle screw fixation of artificial vertebral body for cervical tuberculosis","volume":"127","author":"Zhang","year":"2019","journal-title":"World Neurosurg"},{"key":"R31-20231002","doi-asserted-by":"crossref","first-page":"E50","DOI":"10.1097\/BRS.0000000000001179","article-title":"Reconstruction of the upper cervical spine using a personalized 3D-printed vertebral body in an adolescent with Ewing sarcoma","volume":"41","author":"Xu","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R32-20231002","doi-asserted-by":"crossref","first-page":"1902","DOI":"10.1007\/s00586-016-4871-z","article-title":"One-step reconstruction with a 3D-printed, custom-made prosthesis after total en bloc sacrectomy: a technical note","volume":"26","author":"Wei","year":"2017","journal-title":"Eur Spine J"},{"key":"R33-20231002","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.wneu.2017.11.160","article-title":"Custom-made titanium 3-dimensional printed interbody cages for treatment of osteoporotic fracture-related spinal deformity","volume":"111","author":"Siu","year":"2018","journal-title":"World Neurosurg"},{"key":"R34-20231002","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/jbm.b.31250","article-title":"Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits","volume":"90","author":"Thomsen","year":"2009","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R35-20231002","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1002\/jbm.a.32337","article-title":"In vivo performance of selective electron beam-melted Ti-6Al-4V structures","volume":"92","author":"Ponader","year":"2010","journal-title":"J Biomed Mater Res A"},{"key":"R36-20231002","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1177\/0885328211431857","article-title":"Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: experimental studies in sheep","volume":"27","author":"Palmquist","year":"2013","journal-title":"J Biomater Appl"},{"key":"R37-20231002","doi-asserted-by":"crossref","first-page":"17964","DOI":"10.1021\/acsami.6b05893","article-title":"Tailored surface treatment of 3D printed porous Ti6Al4V by microarc oxidation for enhanced osseointegration via optimized bone in-growth patterns and interlocked bone\/implant interface","volume":"8","author":"Xiu","year":"2016","journal-title":"ACS Appl Mater Interfaces"},{"key":"R38-20231002","doi-asserted-by":"crossref","first-page":"381814","DOI":"10.1100\/2012\/381814","article-title":"Biomechanics of lateral interbody spacers: going wider for going stiffer","volume":"2012","author":"Pimenta","year":"2012","journal-title":"ScientificWorldJournal"},{"key":"R39-20231002","doi-asserted-by":"crossref","first-page":"2421","DOI":"10.1007\/s00264-013-2101-4","article-title":"Comparison of anterior cervical fusion by titanium mesh cage versus nano-hydroxyapatite\/polyamide cage following single-level corpectomy","volume":"37","author":"Yang","year":"2013","journal-title":"Int Orthop"},{"key":"R40-20231002","doi-asserted-by":"crossref","first-page":"2891","DOI":"10.1007\/s00586-013-2976-1","article-title":"Evaluation of a new type of titanium mesh cage versus the traditional titanium mesh cage for single-level, anterior cervical corpectomy and fusion","volume":"22","author":"Fengbin","year":"2013","journal-title":"Eur Spine J"},{"key":"R41-20231002","doi-asserted-by":"crossref","first-page":"160","DOI":"10.5435\/JAAOS-D-16-00390","article-title":"The effect of cervical interbody cage morphology, material composition, and substrate density on cage subsidence","volume":"25","author":"Suh","year":"2017","journal-title":"J Am Acad Orthop Surg"},{"key":"R42-20231002","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1002\/jor.22293","article-title":"Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects","volume":"31","author":"Van der Stok","year":"2013","journal-title":"J Orthop Res"},{"key":"R43-20231002","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1590\/S1806-83242010000400005","article-title":"Evaluation of bone ingrowth into porous titanium implant: histomorphometric analysis in rabbits","volume":"24","author":"Vasconcellos","year":"2010","journal-title":"Braz Oral Res"},{"key":"R44-20231002","first-page":"391","article-title":"Mechanisms of endosseous integration","volume":"11","author":"Davies","year":"1998","journal-title":"Int J Prosthodont"},{"key":"R45-20231002","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1002\/j.0022-0337.2003.67.8.tb03681.x","article-title":"Understanding peri-implant endosseous healing","volume":"67","author":"Davies","year":"2003","journal-title":"J Dent Educ"},{"key":"R46-20231002","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1111\/os.12098","article-title":"Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration","volume":"6","author":"Rao","year":"2014","journal-title":"Orthop Surg"},{"key":"R47-20231002","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1002\/jbm.a.31468","article-title":"Bone growth in rapid prototyped porous titanium implants","volume":"85","author":"Lopez-Heredia","year":"2008","journal-title":"J Biomed Mater Res A"},{"key":"R48-20231002","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1097\/BSD.0b013e3182425eab","article-title":"The effect of angular mismatch between vertebral endplate and vertebral body replacement endplate on implant subsidence","volume":"26","author":"Mohammad-Shahi","year":"2013","journal-title":"J Spinal Disord Tech"},{"key":"R49-20231002","first-page":"1","article-title":"An economic cost model for patient-specific intervertebral disc implants","volume":"95","author":"De Beer","year":"2011","journal-title":"ISEM Proc"},{"key":"R50-20231002","doi-asserted-by":"crossref","first-page":"2753","DOI":"10.1097\/00007632-200212150-00003","article-title":"One versus two BAK fusion cages in posterior lumbar interbody fusion to L4-L5 degenerative spondylolisthesis: a randomized, controlled prospective study in 25 patients with minimum two-year follow-up","volume":"27","author":"Zhao","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R53-20231002","doi-asserted-by":"crossref","first-page":"eaan6521","DOI":"10.1126\/scitranslmed.aan6521","article-title":"Regulating 3D-printed medical products","volume":"10","author":"Ricles","year":"2018","journal-title":"Sci Transl Med"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001026","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T19:21:09Z","timestamp":1723144869000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001026"}},"subtitle":["A Systematic Review"],"short-title":[],"issued":{"date-parts":[[2020,6,16]]},"references-count":49,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001026","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6,16]]}}}