{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:32:52Z","timestamp":1789014772073,"version":"build-2803163510"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>A single center, observational prospective clinical study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The aim of this study was to compare the instrumentation-related cost and efficiency of single-use instrumentation versus traditional reusable instrument trays.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Single-use instrumentation provides the opportunity to reduce costs associated with cleaning and sterilizing instrumentation after surgery. Although previous studies have shown single-use instrumentation is effective in other orthopedic specialties, it is unclear if single-use instrumentation could provide economic advantages in spine surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>A total of 40 (20 reusable instrumentation and 20 single-use instrumentation) lumbar decompression (1\u20133 level) and fusion (1 level) spine surgeries were collected. Instrument handling, opening, setup, re-stocking, cleaning, sterilization, inspection, packaging, and storage were recorded by direct observation for both reusable and single-use instrumentation. The rate of infection was noted for each group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Mean time of handling instruments by the scrub nurse was 11.6 (\u00b13.9) minutes for reusable instrumentation and 2.1 (\u00b10.5) minutes for single-use instrumentation. Mean cost of handling reusable instruments was estimated to be $8.52 (\u00b1$2.96) per case, and the average cost to reprocess a single tray by Sterilization Processing Department (SPD) was $58. Thus, the median cost for sterilizing 2 reusable trays per case was $116, resulting in an average total Cost<jats:sub>resuable<\/jats:sub> of $124.52 (\u00b1$2.96). Mean cost of handling single-use instrumentation was estimated to be $1.57 ($0.38) per case.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Single-use instrumentation provided greater cost savings and reduced time from the opening of instrumentation to use in surgery when compared with reusable instrumentation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001033","type":"journal-article","created":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:28:13Z","timestamp":1593563293000},"page":"E39-E44","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Processing and Handling Cost of Single-use Versus Traditional Instrumentation for 1 Level Lumbar Fusions"],"prefix":"10.1097","volume":"34","author":[{"given":"Matthew S.","family":"Galetta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Srikanth N.","family":"Divi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark A.","family":"Shapses","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph B.","family":"Hartman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristen J.","family":"Nicholson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dhruv K.C.","family":"Goyal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taolin","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John J.","family":"Mangan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian David","family":"Kaye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark F.","family":"Kurd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barrett I.","family":"Woods","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kris E.","family":"Radcliff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey A.","family":"Rihn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Greg","family":"Anderson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan S.","family":"Hilibrand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher K.","family":"Kepler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander R.","family":"Vaccaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory D.","family":"Schroeder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,6,16]]},"reference":[{"key":"R1-20250621","first-page":"E1227","article-title":"Where the United States spends its spine dollars: expenditures on different ambulatory services for the management of back and neck conditions","volume":"30","author":"Davis","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/j.jamcollsurg.2014.06.019","article-title":"Assessing the magnitude and costs of intraoperative inefficiencies attributable to surgical instrument trays","volume":"219","author":"Stockert","year":"2014","journal-title":"J Am Coll Surg"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"2271","DOI":"10.1016\/j.arth.2015.05.037","article-title":"Cost analysis and surgical site infection rates in total knee arthroplasty comparing traditional vs. single-use instrumentation","volume":"30","author":"Siegel","year":"2015","journal-title":"J Arthroplasty"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s13561-017-0153-7","article-title":"A comparative analysis of a disposable and a reusable pedicle screw instrument kit for lumbar arthrodesis: integrating HTA and MCDA","volume":"7","author":"Ottardi","year":"2017","journal-title":"Health Econ Rev"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/j.arth.2013.02.020","article-title":"Single-use instruments, cutting blocks, and trials increase efficiency in the operating room during total knee arthroplasty: a prospective comparison of navigated and non-navigated cases","volume":"28","author":"Mont","year":"2013","journal-title":"J Arthroplasty"},{"key":"R6-20250621","first-page":"243","article-title":"Single-use instrumentation technologies in knee arthroplasty: state of the art","volume":"28","author":"Dell\u2019Osso","year":"2016","journal-title":"Surg Technol Int"},{"key":"R7-20250621","first-page":"82","article-title":"Surgical instrumentation: the true cost of instrument trays and a potential strategy for optimization","volume":"4","author":"Mhlaba","year":"2015","journal-title":"J Hosp Adm"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/s00590-015-1692-4","article-title":"Single-use instrumentation in posterior lumbar fusion could decrease incidence of surgical site infection: a prospective bi-centric study","volume":"26","author":"Litrico","year":"2016","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R9-20250621","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1007\/s00586-017-5447-2","article-title":"The impact of surgeon volume on patient outcome in spine surgery: a systematic review","volume":"27","author":"Malik","year":"2018","journal-title":"Eur Spine J"},{"key":"R10-20250621","first-page":"326","article-title":"Procedure simplification: the role of single-use instruments in total knee arthroplasty","volume":"22","author":"Bhadra","year":"2012","journal-title":"Surg Technol Int"},{"key":"R11-20250621","doi-asserted-by":"crossref","first-page":"2227","DOI":"10.1007\/s00167-013-2626-5","article-title":"Patient-specific instruments: industry\u2019s innovation with a surgeon\u2019s interest","volume":"21","author":"Thienpont","year":"2013","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"E1227","DOI":"10.1097\/BSD.0000000000000504","article-title":"Value in single-level lumbar discectomy: surgical disposable item cost and relationship to patient-reported outcomes","volume":"30","author":"Rosenbaum","year":"2017","journal-title":"Clin Spine Surg"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1007\/s00167-017-4800-7","article-title":"Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases","volume":"26","author":"Schoenmakers","year":"2018","journal-title":"Knee Surgery, Sport Traumatol Arthrosc"},{"key":"R14-20250621","first-page":"331","article-title":"The use of disposable cutting blocks and trials for primary total knee arthroplasty","volume":"22","author":"Bonutti","year":"2010","journal-title":"Tech Knee Surg"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/BLO.0b013e318065b0bc","article-title":"Sterilization wrap inspections do not adequately evaluate instrument sterility","volume":"462","author":"Waked","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"R16-20250621","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1002\/path.1880","article-title":"Pathogenesis and prevalence of variant Creutzfeldt-Jakob disease","volume":"208","author":"Hilton","year":"2006","journal-title":"J Pathol"},{"key":"R17-20250621","doi-asserted-by":"crossref","first-page":"2905","DOI":"10.1099\/vir.0.82961-0","article-title":"Enzymatic detergent treatment protocol that reduces protease-resistant prion protein load and infectivity from surgical-steel monofilaments contaminated with a human-derived prion strain","volume":"88","author":"Lawson","year":"2007","journal-title":"J Gen Virol"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001033","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T23:01:49Z","timestamp":1750546909000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001033"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,16]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001033","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6,16]]},"assertion":[{"value":"2019-07-01","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-04-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}