{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T02:53:03Z","timestamp":1776394383103,"version":"3.51.2"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>This was a retrospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The objective of this study was to compare implant-related complications between mixed-metal and same-metal rod-screw constructs in patients who underwent posterior fusion for adult spinal deformity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Contact between dissimilar metals is discouraged due to potential for galvanic corrosion, increasing the risk for metal toxicity, infection, and implant failure. In spine surgery, titanium (Ti) screws are most commonly used, but Ti rods are notch sensitive and likely more susceptible to fracture after contouring for deformity constructs. Cobalt chrome (CC) and stainless steel (SS) rods may be suitable alternatives. No studies have yet evaluated implant-related complications among mixed-metal constructs (SS or CC rods with Ti screws).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Adults with spinal deformity who underwent at least 5-level thoracic and\/or lumbar posterior fusion or 3-column osteotomy between January 2013 and May 2015 were reviewed, excluding neuromuscular deformity, tumor, acute trauma or infection. Implant-related complications included pseudarthrosis, proximal junctional kyphosis, hardware failure (rod fracture, screw pullout or haloing), symptomatic hardware, and infection.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 61 cases met inclusion criteria: 24 patients received Ti rods with Ti screws (Ti-Ti, 39%), 31 SS rods (SS-Ti, 51%), and 6 CC rods (CC-Ti, 9.8%). Median follow-up was 37\u201342 months for all groups. Because of the limited number of cases, the CC-Ti group was not included in statistical analyses. There were no differences between Ti-Ti and SS-Ti groups with regard to age, body mass index, or smokers. Implant-related complications did not differ between the Ti-Ti and SS-Ti groups (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.080). Among the Ti-Ti group, there were 15 implant-related complications (63%). In the SS-Ti group, there were 12 implant-related complications (39%). There were 3 implant-related complications in the CC-Ti group (50%).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>We found no evidence that combining Ti screws with SS rods increases the risk for implant-related complications.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001058","type":"journal-article","created":{"date-parts":[[2020,9,13]],"date-time":"2020-09-13T13:01:42Z","timestamp":1600002102000},"page":"E121-E125","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Rod-Screw Constructs Composed of Dissimilar Metals Do Not Affect Complication Rates in Posterior Fusion Surgery Performed for Adult Spinal Deformity"],"prefix":"10.1097","volume":"34","author":[{"given":"Sahitya K.","family":"Denduluri","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jayme C.B.","family":"Koltsov","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chason","family":"Ziino","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicole","family":"Segovia","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Craig","family":"McMains","sequence":"additional","affiliation":[{"name":"Community Health Network, Indianapolis, IN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Falakassa","sequence":"additional","affiliation":[{"name":"Southern California Orthopaedic Institute, Van Nuys"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Ratliff","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Stanford University, Stanford, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kirkham B.","family":"Wood","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Todd","family":"Alamin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ivan","family":"Cheng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serena S.","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford University, Redwood City, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,9,11]]},"reference":[{"key":"R1-20250621","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1177\/1938640011422597","article-title":"Combining dissimilar metals in orthopaedic implants: revisited","volume":"4","author":"Zartman","year":"2011","journal-title":"Foot Ankle Spec"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"268","DOI":"10.2106\/00004623-199802000-00015","article-title":"Corrosion of metal orthopaedic implants","volume":"80","author":"Jacobs","year":"1998","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.2106\/00004623-198365080-00012","article-title":"Corrosion of titanium\/cobalt-chromium alloy couples","volume":"65","author":"Kummer","year":"1983","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.spinee.2003.12.004","article-title":"Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?","volume":"4","author":"Serhan","year":"2004","journal-title":"Spine J"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2106\/00004623-196042010-00007","article-title":"The ionization of metal implants in living tissues","volume":"42-A","author":"Ferguson","year":"1960","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20250621","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1080\/17453674.1997.11744741","article-title":"Coexistence of dissimilar metals after conversion of intertrochanteric osteotomy to total hip arthroplasty. 18 patients followed for 5-20 years after conversion","volume":"275","author":"Papapolychroniou","year":"1997","journal-title":"Acta Orthop Scand Suppl"},{"key":"R7-20250621","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2015\/758123","article-title":"Head-neck taper corrosion in hip arthroplasty","author":"Hussenbocus","year":"2015","journal-title":"Biomed Res Int"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1002\/jbm.b.33858","article-title":"Assessment of corrosion in retrieved spine implants","volume":"106","author":"Panagiotopoulou","year":"2018","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R9-20250621","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1016\/j.spinee.2013.04.022","article-title":"Rods in spinal surgery: a review of the literature","volume":"13","author":"Yoshihara","year":"2013","journal-title":"Spine J"},{"key":"R10-20250621","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.injury.2007.07.015","article-title":"Should the galvanic combination of titanium and stainless steel surgical implants be avoided?","volume":"39","author":"H\u00f8l","year":"2008","journal-title":"Injury"},{"key":"R11-20250621","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/761967","article-title":"The biological effects of combining metals in a posterior spinal implant: in vivo model development report of the first two cases","author":"Farnsworth","year":"2014","journal-title":"Adv Orthop Surg"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"e1175","DOI":"10.3928\/01477447-20130821-21","article-title":"Mixing implants of differing metallic composition in the treatment of upper-extremity fractures","volume":"36","author":"Acevedo","year":"2013","journal-title":"Orthopedics"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.1097\/01.brs.0000224177.97846.00","article-title":"The effects of rod contouring on spinal construct fatigue strength","volume":"31","author":"Lindsey","year":"2006","journal-title":"Spine"},{"key":"R14-20250621","doi-asserted-by":"crossref","first-page":"e520","DOI":"10.3928\/01477447-20150603-61","article-title":"Influence of rod contouring on rod strength and stiffness in spine surgery","volume":"38","author":"Demura","year":"2015","journal-title":"Orthopedics"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.jspd.2013.08.004","article-title":"The effect of contouring on fatigue strength of spinal rods: is it okay to re-bend and which materials are best?","volume":"1","author":"Slivka","year":"2013","journal-title":"Spine Deform"},{"key":"R16-20250621","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.1097\/00007632-200108010-00008","article-title":"Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants","volume":"26","author":"Dick","year":"2001","journal-title":"Spine"},{"key":"R17-20250621","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1002\/jbm.820170308","article-title":"In vitro electrochemical corrosion study of coupled surgical implant materials","volume":"17","author":"Griffin","year":"1983","journal-title":"J Biomed Mater Res"},{"key":"R19-20250621","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1016\/j.jhsa.2015.03.030","article-title":"An overview of internal fixation implant metallurgy and galvanic corrosion effects","volume":"40","author":"Koh","year":"2015","journal-title":"J Hand Surg"},{"key":"R20-20250621","doi-asserted-by":"crossref","first-page":"994","DOI":"10.3171\/2014.9.SPINE131176","article-title":"Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity","volume":"21","author":"Smith","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"R21-20250621","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.1016\/j.spinee.2018.02.008","article-title":"Rod fracture in adult spinal deformity surgery fused to the sacrum: prevalence, risk factors, and impact on health-related quality of life in 526 patients","volume":"18","author":"Lertudomphonwanit","year":"2018","journal-title":"Spine J"},{"key":"R22-20250621","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1007\/s005860000204","article-title":"Augmentation of mechanical properties in osteoporotic vertebral bones\u2014a biomechanical investigation of vertebroplasty efficacy with different bone cements","volume":"10","author":"Heini","year":"2001","journal-title":"Eur Spine J"},{"key":"R23-20250621","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.spinee.2017.02.005","article-title":"Rod stiffness as a risk factor of proximal junctional kyphosis after adult spinal deformity surgery: comparative study between cobalt chrome multiple-rod constructs and titanium alloy two-rod constructs","volume":"17","author":"Han","year":"2017","journal-title":"Spine J"},{"key":"R24-20250621","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1093\/rb\/rbw016","article-title":"Biomedical titanium alloys with Young\u2019s moduli close to that of cortical bone","volume":"3","author":"Niinomi","year":"2016","journal-title":"Regen Biomater"},{"issue":"suppl 1","key":"R25-20250621","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s00586-011-1754-1","article-title":"Late-developing infection following posterior fusion for adolescent idiopathic scoliosis","volume":"20","author":"Silvestre","year":"2011","journal-title":"Eur Spine J"},{"key":"R26-20250621","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.wneu.2017.04.031","article-title":"Comparative study between cobalt chrome and titanium alloy rods for multilevel spinal fusion: proximal junctional kyphosis more frequently occurred in patients having cobalt chrome rods","volume":"103","author":"Han","year":"2017","journal-title":"World Neurosurg"},{"key":"R27-20250621","doi-asserted-by":"crossref","first-page":"126","DOI":"10.14245\/kjs.2017.14.4.126","article-title":"Proximal junctional kyphosis and proximal junctional failure following adult spinal deformity surgery","volume":"14","author":"Hyun","year":"2017","journal-title":"Korean J Spine"},{"key":"R28-20250621","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1227\/NEU.0b013e3182672aab","article-title":"Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity","volume":"71","author":"Smith","year":"2012","journal-title":"Neurosurgery"},{"key":"R29-20250621","doi-asserted-by":"crossref","first-page":"132","DOI":"10.13105\/wjma.v5.i6.132","article-title":"Different types of mechanical complications after surgical correction of adult spine deformity with osteotomy","volume":"5","author":"Barton","year":"2017","journal-title":"World J Meta-Anal"},{"key":"R30-20250621","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1097\/00007632-200104150-00025","article-title":"Long-term complications in adult spinal deformity patients having combined surgery a comparison of primary to revision patients","volume":"26","author":"Lapp","year":"2001","journal-title":"Spine"},{"key":"R31-20250621","doi-asserted-by":"crossref","first-page":"207","DOI":"10.4103\/sni.sni_44_17","article-title":"Biomechanical study of rod stress after pedicle subtraction osteotomy versus anterior column reconstruction: a finite element study","volume":"8","author":"Januszewski","year":"2017","journal-title":"Surg Neurol Int"},{"key":"R32-20250621","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/s13013-015-0056-5","article-title":"Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a retrospective case-series","volume":"10","author":"Barton","year":"2015","journal-title":"Scoliosis"},{"key":"R33-20250621","doi-asserted-by":"crossref","first-page":"S4","DOI":"10.1097\/BRS.0000000000002020","article-title":"Biological responses to spinal implant debris","volume":"42","author":"Hallab","year":"2017","journal-title":"Spine"},{"key":"R34-20250621","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S1529-9430(02)00443-6","article-title":"The effect of spinal instrumentation particulate wear debris. an in vivo rabbit model and applied clinical study of retrieved instrumentation cases","volume":"3","author":"Cunningham","year":"2003","journal-title":"Spine J"},{"key":"R35-20250621","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1302\/0301-620X.78B4.0780647","article-title":"Influence of materials for fixation implants on local infection. An experimental study of steel versus titanium DCP in rabbits","volume":"78","author":"Arens","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"R36-20250621","first-page":"193","article-title":"Late postoperative infection following spinal instrumentation: stainless steel versus titanium implants","volume":"17","author":"Soultanis","year":"2008","journal-title":"J Surg Orthop Adv"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001058","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T23:01:09Z","timestamp":1750546869000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,11]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001058","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2020,9,11]]},"assertion":[{"value":"2020-01-02","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}