{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:38:24Z","timestamp":1787009904778,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Retrospective review.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The aim was to evaluate the learning curve of skin-anchored intraoperative navigation (ION) for minimally invasive lumbar surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>ION is increasingly being utilized to provide better visualization, improve accuracy, and enable less invasive procedures. The use of noninvasive skin-anchored trackers for navigation is a novel technique, with the few reports on this technique demonstrating safety, feasibility, and significant reductions in radiation exposure compared with conventional fluoroscopy. However, a commonly cited deterrent to wider adoption is the learning curve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Retrospective review of patients undergoing 1-level minimally invasive lumbar surgery was performed. Outcomes were: (1) time for ION set-up and image-acquisition; (2) operative time; (3) fluoroscopy time; (4) radiation dose; (5) operative complications; (6) need for repeat spin; (7) incorrect localization.<\/jats:p>\n                    <jats:p>Chronologic case number was plotted against each outcome. Derivative of the nonlinear curve fit to the dataset for each outcome was solved to find plateau in learning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 270 patients [114 microdiscectomy; 79 laminectomy; 77 minimally invasive transforaminal lumbar interbody fusion (MI-TLIF)] were included. (1) ION set-up and image-acquisition: no learning curve for microdiscectomy. Proficiency at 23 and 31 cases for laminectomy and MI-TLIF, respectively. (2) Operative time: no learning curve for microdiscectomy. Proficiency at 36 and 31 cases for laminectomy and MI-TLIF, respectively. (3) Fluoroscopy time: no learning curve. (4) Radiation dose: proficiency at 42 and 33 cases for microdiscectomy and laminectomy, respectively. No learning curve for MI-TLIF. (5) Operative complications: unable to evaluate for microdiscectomy and MI-TLIF. Proficiency at 29 cases for laminectomy. (6) Repeat spin: unable to evaluate for microdiscectomy and laminectomy. For MI-TLIF, chronology was not associated with repeat spins. (7) Incorrect localization: none.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Skin-anchored ION did not result in any wrong level surgeries. Learning curve for other parameters varied by surgery type, but was achieved at 25\u201335 cases for a majority of outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level III.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001167","type":"journal-article","created":{"date-parts":[[2021,3,26]],"date-time":"2021-03-26T16:15:11Z","timestamp":1616775311000},"page":"E111-E120","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Time-demand, Radiation Exposure and Outcomes of Minimally Invasive Spine Surgery With the Use of Skin-Anchored Intraoperative Navigation"],"prefix":"10.1097","volume":"35","author":[{"given":"Avani S.","family":"Vaishnav","sequence":"first","affiliation":[{"name":"Hospital for Special Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catherine H.","family":"Gang","sequence":"additional","affiliation":[{"name":"Hospital for Special Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheeraz A.","family":"Qureshi","sequence":"additional","affiliation":[{"name":"Hospital for Special Surgery"},{"name":"Weill Cornell Medical College, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,3,23]]},"reference":[{"key":"R1-20250621","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1007\/s00402-018-2994-x","article-title":"Learning curve analysis of 3D-fluoroscopy image-guided pedicle screw insertions in lumbar single-level fusion procedures","volume":"138","author":"Balling","year":"2018","journal-title":"Arch Orthop Trauma Surg"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"S86","DOI":"10.1093\/neuros\/nyw077","article-title":"Navigation and robotics in spinal surgery: where are we now?","volume":"80","author":"Overley","year":"2017","journal-title":"Clin Neurosurg"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1097\/BRS.0000000000001437","article-title":"Imaging, navigation, and robotics in spine surgery","volume":"41","author":"Johnson","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.wneu.2012.03.011","article-title":"Worldwide survey on the use of navigation in spine surgery","volume":"79","author":"H\u00e4rtl","year":"2013","journal-title":"World Neurosurg"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"323","DOI":"10.4103\/2152-7806.159381","article-title":"Economics of image guidance and navigation in spine surgery","volume":"6","author":"Al-Khouja","year":"2015","journal-title":"Surg Neurol Int"},{"key":"R6-20250621","doi-asserted-by":"crossref","first-page":"E512","DOI":"10.1097\/BRS.0000000000002422","article-title":"Time demand and radiation dose in 3D-fluoroscopy-based navigation-assisted 3D-fluoroscopy-controlled pedicle screw instrumentations","volume":"43","author":"Balling","year":"2018","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20250621","doi-asserted-by":"crossref","first-page":"357","DOI":"10.3171\/2017.7.SPINE17528","article-title":"Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers","volume":"28","author":"Malham","year":"2018","journal-title":"J Neurosurg Spine"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.wneu.2018.05.159","article-title":"Pedicle screw revision in robot-guided, navigated, and freehand thoracolumbar instrumentation: a systematic review and meta-analysis","volume":"116","author":"Staartjes","year":"2018","journal-title":"World Neurosurg"},{"key":"R9-20250621","doi-asserted-by":"crossref","first-page":"800","DOI":"10.5435\/JAAOS-22-12-800","article-title":"Imaging modalities in orthopaedic surgery\u202f: a narrative review","volume":"22","author":"Qureshi","year":"2014","journal-title":"J Acad Orthop Surg"},{"key":"R10-20250621","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1007\/s11999.0000000000000204","article-title":"Increased radiation but no benefits in pedicle screw accuracy with navigation versus a freehand technique in scoliosis surgery","volume":"476","author":"Urbanski","year":"2018","journal-title":"Clin Orthop Relat Res"},{"key":"R11-20250621","doi-asserted-by":"crossref","first-page":"1918","DOI":"10.1007\/s00586-018-5587-z","article-title":"Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement","volume":"27","author":"Tajsic","year":"2018","journal-title":"Eur Spine J"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"5027340","DOI":"10.1155\/2016\/5027340","article-title":"Total 3D Airo\u00ae navigation for minimally invasive transforaminal lumbar interbody fusion","volume":"2016","author":"Lian","year":"2016","journal-title":"Biomed Res Int"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.wneu.2017.01.025","article-title":"Total navigation in spine surgery; a concise guide to eliminate fluoroscopy using a portable intraoperative computed tomography 3-dimensional navigation system","volume":"100","author":"Navarro-Ramirez","year":"2017","journal-title":"World Neurosurg"},{"key":"R14-20250621","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1097\/BSD.0000000000000616","article-title":"One-step minimally invasive pedicle screw instrumentation using o-arm and stealth navigation","volume":"31","author":"Kleck","year":"2018","journal-title":"Clin Spine Surg"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"e410","DOI":"10.1016\/j.wneu.2017.12.080","article-title":"Comparative cohort study of percutaneous pedicle screw implantation without versus with navigation in patients undergoing surgery for degenerative lumbar disc disease","volume":"111","author":"Fomekong","year":"2018","journal-title":"World Neurosurg"},{"issue":"suppl 1","key":"R16-20250621","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.21037\/jss.2019.04.23","article-title":"Navigation in minimally invasive spine surgery","volume":"5","author":"Virk","year":"2019","journal-title":"J Spine Surg"},{"key":"R17-20250621","doi-asserted-by":"crossref","first-page":"E465","DOI":"10.1097\/BRS.0000000000003310","article-title":"A review of techniques, time demand, radiation exposure, and outcomes of skin-anchored intraoperative 3D navigation in minimally invasive lumbar spinal surgery","volume":"45","author":"Vaishnav","year":"2020","journal-title":"Spine (Phila Pa 1976)"},{"key":"R18-20250621","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1093\/ons\/opz240","article-title":"Retrospective review of immediate restoration of lordosis in single-level minimally invasive transforaminal lumbar interbody fusion: a comparison of static and expandable interbody cages","volume":"18","author":"Vaishnav","year":"2020","journal-title":"Oper Neurosurg"},{"key":"R19-20250621","doi-asserted-by":"crossref","first-page":"46","DOI":"10.14444\/6007","article-title":"Predictive factors and rates of fusion in minimally invasive transforaminal lumbar interbody fusion utilizing rhBMP-2 or mesenchymal stem cells","volume":"13","author":"Overley","year":"2019","journal-title":"Int J Spine Surg"},{"key":"R20-20250621","doi-asserted-by":"crossref","first-page":"39","DOI":"10.14444\/6006","article-title":"Radiation exposure in minimally invasive transforaminal lumbar interbody fusion: the effect of the learning curve","volume":"13","author":"Kumar","year":"2019","journal-title":"Int J Spine Surg"},{"key":"R22-20250621","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1097\/CORR.0000000000000596","article-title":"Pearls: improving upon minimally invasive transforaminal lumbar interbody fusion","volume":"477","author":"Qureshi","year":"2019","journal-title":"Clin Orthop Relat Res"},{"key":"R23-20250621","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/S1935-9810(08)70038-0","article-title":"Surgeons\u2019 perceptions of spinal navigation: analysis of key factors affecting the lack of adoption of spinal navigation technology","volume":"2","author":"Choo","year":"2008","journal-title":"SAS J"},{"key":"R24-20250621","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1007\/s11999-013-3291-1","article-title":"What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?","volume":"472","author":"Hu","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"R25-20250621","doi-asserted-by":"crossref","first-page":"27","DOI":"10.14444\/1027","article-title":"The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring\u2014a retrospective review of 627 screws in 150 patients","volume":"8","author":"Wood","year":"2014","journal-title":"Int J Spine Surg"},{"key":"R26-20250621","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.spinee.2014.10.003","article-title":"Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine","volume":"15","author":"Ryang","year":"2015","journal-title":"Spine J"},{"key":"R27-20250621","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jocn.2016.02.033","article-title":"Effect of intraoperative navigation on operative time in 1-level lumbar fusion surgery","volume":"32","author":"Khanna","year":"2016","journal-title":"J Clin Neurosci"},{"key":"R28-20250621","first-page":"1","article-title":"Computer-assisted, minimally invasive transforaminal lumbar interbody fusion","volume":"97","author":"Xu","year":"2018","journal-title":"Med (United States)"},{"key":"R29-20250621","doi-asserted-by":"crossref","first-page":"29","DOI":"10.4103\/0971-6203.152244","article-title":"Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system","volume":"40","author":"Sharma","year":"2015","journal-title":"J Med Phys"},{"key":"R30-20250621","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1111\/bju.12197","article-title":"Measuring the surgical \u201clearning curve\u201d: methods, variables and competency","volume":"113","author":"Khan","year":"2014","journal-title":"BJU Int"},{"key":"R31-20250621","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1016\/j.spinee.2013.08.045","article-title":"Minimally invasive transforaminal lumbar interbody fusion: one surgeon\u2019s learning curve","volume":"14","author":"Nandyala","year":"2014","journal-title":"Spine J"},{"key":"R32-20250621","doi-asserted-by":"crossref","first-page":"20","DOI":"10.21182\/jmisst.2019.00059","article-title":"Learning curve of MIS-TLIF using 22 mm-tubular retractor in degenerative spondylolisthesis (grade 1-2)\u2014a review over 100 cases","volume":"5","author":"Mehta","year":"2020","journal-title":"JMISST J Minim Invasive Spine Surg Tech"},{"key":"R33-20250621","doi-asserted-by":"crossref","first-page":"2419","DOI":"10.1007\/s11999-010-1393-6","article-title":"Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?","volume":"468","author":"Kraus","year":"2010","journal-title":"Clin Orthop Relat Res"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001167","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T18:04:36Z","timestamp":1750529076000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001167"}},"subtitle":["The Effect of the Learning Curve"],"short-title":[],"issued":{"date-parts":[[2021,3,23]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001167","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3,23]]},"assertion":[{"value":"2020-07-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}