{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T07:28:07Z","timestamp":1775806087843,"version":"3.50.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>A retrospective study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To describe the modified iliac screw (mILS) technique and compare it to other spinopelvic fixation techniques in terms of wound healing complications, hardware prominence, and failure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>The traditional entry point of an iliac screw often causes postoperative gluteal pain from the prominent screw head. The use of an offset connector also adds a point of weakness to the construct. By choosing a different screw entry point offset connectors can be avoided, and the screw head itself is less prominent, thereby reducing postoperative discomfort.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>A retrospective analysis was performed of adult patients undergoing lumbopelvic fixation (LPF) between January 2014 and June 2019. Patients were grouped into 1 of 3 groups based on the technique of pelvic fixation: S2 alar-iliac (S2AI) screw, traditional iliac screw (tILS), and mILS. The primary outcome parameter was the minimal distance from screw head to skin. Secondary outcome parameters were instrumentation loosening\/failure, adjacent level fractures, pseudoarthrosis, and medial or lateral iliac screw perforation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 190 patients undergoing LPF were included in the following 3 groups: mILS group (n=113), tILS group (n=40), and S2AI group (n=37). The mean minimal distance from screw head to skin in the mILS group was 31.3\u2009mm compared with 23.7\u2009mm in the tILS group (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.00199). No statistically significant differences were found when comparing the 3 groups with respect to complications. The mILS group did not show any cases of prominent instrumentation and had the lowest rate of instrumentation failure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The mILS technique is an acceptable alternative for LPF, offering the benefits of iliac screw fixation while avoiding offset connectors and screw prominence complications associated with tILS.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Level III.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001182","type":"journal-article","created":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T03:57:50Z","timestamp":1619495870000},"page":"E127-E131","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Iliac Screw Fixation Revisited"],"prefix":"10.1097","volume":"35","author":[{"given":"Alexander","family":"von Glinski","sequence":"first","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"},{"name":"Department of Trauma Surgery, BG University Hospital Bergmannsheil, Ruhr University Bochum, Bochum, Germany"},{"name":"Hansj\u00f6rg Wyss Hip and Pelvic Center, Swedish Hospital, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher J.","family":"Elia","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"},{"name":"Riverside University Health System Medical Center, Moreno Valley, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James G.","family":"Wiginton","sequence":"additional","affiliation":[{"name":"Riverside University Health System Medical Center, Moreno Valley, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Darius","family":"Ansari","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clifford","family":"Pierre","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Basem","family":"Ishak","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"},{"name":"Department of Neurosurgery, Heidelberg University Hospital, Heidelberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emre","family":"Yilmaz","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronen","family":"Blecher","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph R.","family":"Dettori","sequence":"additional","affiliation":[{"name":"Spectrum Research Inc, Tacoma, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erik","family":"Hayman","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas A.","family":"Schildhauer","sequence":"additional","affiliation":[{"name":"Department of Trauma Surgery, BG University Hospital Bergmannsheil, Ruhr University Bochum, Bochum, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rod J.","family":"Oskouian","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens R.","family":"Chapman","sequence":"additional","affiliation":[{"name":"Swedish Neuroscience Institute, Swedish Medical Center"},{"name":"Seattle Science Foundation, Seattle, WA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,4,23]]},"reference":[{"key":"R1-20250621","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/00024720-200206000-00005","article-title":"Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations","volume":"15","author":"Schildhauer","year":"2002","journal-title":"J Spinal Disord Tech"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1007\/s00586-014-3615-1","article-title":"Sacropelvic fixation in adult spinal deformity (ASD); a very high rate of mechanical failure","volume":"24","author":"Guler","year":"2015","journal-title":"Eur Spine J"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/01.brs.0000197193.81296.f1","article-title":"Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity","volume":"31","author":"Tsuchiya","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1097\/BSD.0b013e3181cc8e7f","article-title":"Long-term results of iliac wing fixation below extensive fusions in ambulatory adult patients with spinal disorders","volume":"23","author":"Kasten","year":"2010","journal-title":"J Spinal Disord Tech"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"347","DOI":"10.3340\/jkns.2010.48.4.347","article-title":"A mid-term follow-up result of spinopelvic fixation using iliac screws for lumbosacral fusion","volume":"48","author":"Hyun","year":"2010","journal-title":"J Korean Neurosurg Soc"},{"key":"R6-20250621","doi-asserted-by":"crossref","first-page":"e296","DOI":"10.1016\/j.wneu.2018.02.009","article-title":"S2 alar-iliac screw insertion: technical note with pictorial guide","volume":"113","author":"Yilmaz","year":"2018","journal-title":"World Neurosurg"},{"key":"R7-20250621","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1007\/s00701-016-2772-x","article-title":"Modified iliac screw fixation: technique and clinical application","volume":"158","author":"Sohn","year":"2016","journal-title":"Acta Neurochir (Wien)"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1097\/BRS.0b013e318194128c","article-title":"Low profile pelvic fixation: anatomic parameters for sacral alar-iliac fixation versus traditional iliac fixation","volume":"34","author":"Chang","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"R9-20250621","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1097\/BSD.0b013e31818da3e2","article-title":"Iliac bolt fixation: an anatomic approach","volume":"22","author":"Harrop","year":"2009","journal-title":"J Spinal Disord Tech"},{"key":"R10-20250621","doi-asserted-by":"crossref","first-page":"E68","DOI":"10.1097\/BRS.0000000000002239","article-title":"Subcrestal iliac-screw: a technical note describing a free hand, in-line, low profile iliac screw insertion technique to avoid side-connector use and reduce implant complications","volume":"43","author":"Liu","year":"2018","journal-title":"Spine (Phila Pa 1976)"},{"key":"R11-20250621","doi-asserted-by":"crossref","DOI":"10.3171\/2018.9.SPINE18239","article-title":"Low rates of complications after spinopelvic fixation with iliac screws in 260 adult patients with a minimum 2-year follow-up","author":"Nguyen","year":"2019","journal-title":"J Neurosurg Spine"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.wneu.2016.06.042","article-title":"S2-alar-iliac screws are associated with lower rate of symptomatic screw prominence than iliac screws: radiographic analysis of minimal distance from screw head to skin","volume":"93","author":"Ishida","year":"2016","journal-title":"World Neurosurg"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"E142","DOI":"10.1097\/BRS.0000000000001722","article-title":"Use of S2-alar-iliac screws associated with less complications than iliac screws in adult lumbosacropelvic fixation","volume":"42","author":"Elder","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"R14-20250621","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1177\/2192568217717973","article-title":"Dural tears in adult deformity surgery: incidence, risk factors, and outcomes","volume":"8","author":"Iyer","year":"2018","journal-title":"Global Spine J"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"E8","DOI":"10.3171\/2015.7.FOCUS15266","article-title":"Unintended durotomy in lumbar degenerative spinal surgery: a 10-year systematic review of the literature","volume":"39","author":"Ghobrial","year":"2015","journal-title":"Neurosurg Focus"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001182","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T22:04:23Z","timestamp":1750543463000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001182"}},"subtitle":["Improved Clinical and Radiologic Outcomes Using a Modified Iliac Screw Fixation Technique"],"short-title":[],"issued":{"date-parts":[[2021,4,23]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001182","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2021,4,23]]},"assertion":[{"value":"2020-07-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}