{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T04:12:04Z","timestamp":1780978324960,"version":"3.54.1"},"reference-count":38,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T00:00:00Z","timestamp":1623110400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>This was a retrospective analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The objective of this study was to assess the intraoperative neuromonitoring auxiliary significance of descending neurogenic\u2013evoked potential (DNEP) for motor-evoked potential (MEP) during severe spinal deformity surgery when MEP-positive event occurs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>MEP detection is the most widely applied neurological monitoring technique in spinal deformity surgery. MEP is quite vulnerable to anesthesia, blood pressure, and other intraoperative factors, leading to a high false-positive rate of MEP (3.2%\u201345.0%), which has greatly interfered with the surgical process. At present, the widely used \u201cpresence-or-absence\u201d alarm criteria of MEP is not enough to solve the problem of false positive of MEP.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A total of 205 cases undergoing severe spinal deformity correction were retrospectively studied. Overall, 74 MEP-positive cases were classified as 2 subgroups: DNEP (+) and DNEP (\u2212) groups. The MEP recovery, wake-up test, and Frankle grade were used to assess the neurological functions. The perioperative and long-term neurological outcomes were assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There were significant differences in preoperative scoliosis angle and kyphosis angle between DNEP (\u2212) and DNEP (+) groups. Patients in DNEP (\u2212) group showed more MEP improvement (81.5%), compared with the DNEP (+) group (53.2%). The Wake-up test showed 59.3% motor function deficit cases in DNEP (\u2212) group, which was lower than the 87.2% in DNEP (+) group. More patients in DNEP (\u2212) group had normal nerve function (Frankel level E) than those in DNEP (+) group immediately after surgery, as well as at follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>MEP-positive cases with intraoperative DNEP (\u2212) showed superior prognosis after severe spinal deformity surgery. Intraoperative DNEP could be regarded as an important quantitative tool to assist MEP to monitor neurological injury and can serve as a temporary substitution monitoring technique after MEP is lost.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001190","type":"journal-article","created":{"date-parts":[[2021,6,10]],"date-time":"2021-06-10T05:01:16Z","timestamp":1623301276000},"page":"E167-E174","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Intraoperative Neuromonitoring Auxiliary Significance of DNEP for MEP-positive Event During Severe Spinal Deformity Surgery"],"prefix":"10.1097","volume":"35","author":[{"given":"Jian","family":"Chen","sequence":"first","affiliation":[{"name":"Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yao-long","family":"Deng","sequence":"additional","affiliation":[{"name":"Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen-yuan","family":"Sui","sequence":"additional","affiliation":[{"name":"Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing-fan","family":"Yang","sequence":"additional","affiliation":[{"name":"Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Xu","sequence":"additional","affiliation":[{"name":"Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zi-fang","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, the 1st Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun-lin","family":"Yang","sequence":"additional","affiliation":[{"name":"Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,6,8]]},"reference":[{"key":"R1-20250621","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1007\/s00586-015-4367-2","article-title":"A proposed classification system for guiding surgical strategy in cases of severe spinal deformity based on spinal cord function","volume":"25","author":"Yang","year":"2016","journal-title":"Eur Spine J"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1097\/BRS.0b013e3181b53cba","article-title":"Posterior vertebral column resection for severe pediatric deformity: minimum two-year follow-up of thirty-five consecutive patients","volume":"34","author":"Lenke","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1097\/BRS.0000000000001547","article-title":"Deformity Angular ratio describes the severity of spinal deformity and predicts the risk of neurologic deficit in posterior vertebral column resection surgery","volume":"41","author":"Wang","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"E17","DOI":"10.3171\/2014.2.FOCUS1419","article-title":"Evaluation of complications and neurological deficits with three-column spine reconstructions for complex spinal deformity: a retrospective Scoli-RISK-1 study","volume":"36","author":"Kelly","year":"2014","journal-title":"Neurosurg Focus"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1186\/s13018-018-0902-2","article-title":"Five-year outcomes of posterior affected-vertebrae fixation in lumbar tuberculosis patients","volume":"13","author":"Liang","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R6-20250621","doi-asserted-by":"crossref","first-page":"E101","DOI":"10.1097\/BRS.0b013e31827aafb9","article-title":"Significant change or loss of intraoperative monitoring data: a 25-year experience in 12,375 spinal surgeries","volume":"38","author":"Raynor","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20250621","doi-asserted-by":"crossref","first-page":"E1177","DOI":"10.1097\/BRS.0000000000001678","article-title":"Diagnostic accuracy of combined multimodality somatosensory evoked potential and transcranial motor evoked potential intraoperative monitoring in patients with idiopathic scoliosis","volume":"41","author":"Thirumala","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"E1174","DOI":"10.1097\/BSD.0000000000000388","article-title":"Intraoperative neuromonitoring in pediatric and adult spine deformity surgery","volume":"30","author":"Strike","year":"2017","journal-title":"Clin Spine Surg"},{"issue":"suppl 2","key":"R9-20250621","doi-asserted-by":"crossref","first-page":"S236","DOI":"10.1007\/s00586-007-0498-4","article-title":"The value of bilateral ipsilateral and contralateral motor evoked potential monitoring in scoliosis surgery","volume":"17","author":"Lo","year":"2008","journal-title":"Eur Spine J"},{"key":"R10-20250621","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1097\/01.BRS.0000061995.75709.78","article-title":"Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity: a study of 145 patients","volume":"28","author":"Langeloo","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R11-20250621","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.cnp.2018.12.002","article-title":"Intraoperative neurophysiology monitoring in scoliosis surgery in children","volume":"4","author":"Nagarajan","year":"2019","journal-title":"Clin Neurophysiol Pract"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"571","DOI":"10.3171\/jns.2002.96.3.0571","article-title":"Total intravenous anesthesia for intraoperative monitoring of the motor pathways: an integral view combining clinical and experimental data","volume":"96","author":"Scheufler","year":"2002","journal-title":"J Neurosurg"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/BSD.0b013e3182aa736d","article-title":"Comparison of the wake-up test and combined TES-MEP and CSEP monitoring in spinal surgery","volume":"28","author":"Chen","year":"2015","journal-title":"J Spinal Disord Tech"},{"key":"R14-20250621","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1007\/s10877-017-0057-4","article-title":"Changes in transcranial motor evoked potentials during hemorrhage are associated with increased serum propofol concentrations","volume":"32","author":"Lieberman","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1097\/ALN.0b013e31829d4a92","article-title":"Effect of hemorrhage and hypotension on transcranial motor-evoked potentials in swine","volume":"119","author":"Lieberman","year":"2013","journal-title":"Anesthesiology"},{"key":"R16-20250621","doi-asserted-by":"crossref","first-page":"1440","DOI":"10.1016\/j.spinee.2013.08.037","article-title":"Differential rates of false-positive findings in transcranial electric motor evoked potential monitoring when using inhalational anesthesia versus total intravenous anesthesia during spine surgeries","volume":"14","author":"Tamkus","year":"2014","journal-title":"Spine J"},{"key":"R17-20250621","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1186\/s13018-018-0934-7","article-title":"An evaluation of anesthetic fade in motor evoked potential monitoring in spinal deformity surgeries","volume":"13","author":"Ugawa","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R18-20250621","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1097\/00007632-200204150-00009","article-title":"Factors related to false- versus true-positive neuromonitoring changes in adolescent idiopathic scoliosis surgery","volume":"27","author":"Noonan","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20250621","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1097\/00000542-199611000-00008","article-title":"Effects of isoflurane and desflurane on neurogenic motor- and somatosensory-evoked potential monitoring for scoliosis surgery","volume":"85","author":"Bernard","year":"1996","journal-title":"Anesthesiology"},{"key":"R20-20250621","doi-asserted-by":"crossref","first-page":"S385","DOI":"10.1097\/00007632-199108001-00016","article-title":"The clinical application of neurogenic motor evoked potentials to monitor spinal cord function during surgery","volume":"16","author":"Owen","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"key":"R21-20250621","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/j.spinee.2015.09.028","article-title":"Intraoperative motor evoked potential monitoring to patients with preoperative spinal deficits: judging its feasibility and analyzing the significance of rapid signal loss","volume":"17","author":"Wang","year":"2017","journal-title":"Spine J"},{"key":"R22-20250621","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/00004691-199101000-00013","article-title":"Developing a more focal magnetic stimulator. Part I: some basic principles","volume":"8","author":"Cohen","year":"1991","journal-title":"J Clin Neurophysiol"},{"issue":"suppl 2","key":"R23-20250621","doi-asserted-by":"crossref","first-page":"S140","DOI":"10.1007\/s00586-007-0416-9","article-title":"History of the development of intraoperative spinal cord monitoring","volume":"16","author":"Tamaki","year":"2007","journal-title":"Eur Spine J"},{"key":"R24-20250621","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1186\/1471-2474-12-170","article-title":"Neurophysiologic effects of spinal manipulation in patients with chronic low back pain","volume":"12","author":"Clark","year":"2011","journal-title":"BMC Musculoskelet Disord"},{"key":"R25-20250621","first-page":"1","article-title":"Characteristics of false-positive alerts on transcranial motor evoked potential monitoring during pediatric scoliosis and adult spinal deformity surgery: an \u201canesthetic fade\u201d phenomenon","volume":"22","author":"Ushirozako","year":"2019","journal-title":"J Neurosurg Spine"},{"key":"R26-20250621","first-page":"13","article-title":"Progressive suppression of motor evoked potentials during general anesthesia: the phenomenon of \u201canesthetic fade\u201d","volume":"17","author":"Lyon","year":"2005","journal-title":"J Neurosurg Anesthesiol"},{"key":"R27-20250621","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1007\/s10877-005-5097-5","article-title":"The effects of isoflurane and propofol on intraoperative neurophysiological monitoring during spinal surgery","volume":"18","author":"Chen","year":"2004","journal-title":"J Clin Monit Comput"},{"key":"R28-20250621","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1080\/1086508X.2010.11079776","article-title":"Effects of anesthetic regimens and other confounding factors affecting the interpretation of motor evoked potentials during pediatric spine surgery","volume":"50","author":"Balvin","year":"2010","journal-title":"Am J Electroneurodiagnostic Technol"},{"key":"R29-20250621","doi-asserted-by":"crossref","first-page":"3041","DOI":"10.1097\/BRS.0b013e31815d0072","article-title":"Risk factors for false positive transcranial motor evoked potential monitoring alerts during surgical treatment of cervical myelopathy","volume":"32","author":"Kim","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R30-20250621","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1097\/ANA.0b013e318237fa41","article-title":"High-frequency stimulation restored motor-evoked potentials to the baseline level in the upper extremities but not in the lower extremities under sevoflurane anesthesia in spine surgery","volume":"24","author":"Shida","year":"2012","journal-title":"J Neurosurg Anesthesiol"},{"key":"R31-20250621","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1016\/j.spinee.2016.05.002","article-title":"Rare true-positive outcome of spinal cord monitoring in patients under age 4 years","volume":"16","author":"Wang","year":"2016","journal-title":"Spine J"},{"key":"R32-20250621","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.otsr.2016.09.021","article-title":"Intraoperative spinal cord monitoring: lesional level diagnosis","volume":"103","author":"Gavaret","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"R33-20250621","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1097\/00007632-200207150-00017","article-title":"Combined spinal cord monitoring using neurogenic mixed evoked potentials and collision techniques","volume":"27","author":"Pereon","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R34-20250621","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1016\/S1388-2457(01)00567-3","article-title":"Anterior spinal cord injury with preserved neurogenic \u2018motor\u2019 evoked potentials","volume":"112","author":"Minahan","year":"2001","journal-title":"Clin Neurophysiol"},{"key":"R35-20250621","doi-asserted-by":"crossref","first-page":"64","DOI":"10.4103\/0019-5413.58608","article-title":"Multimodal intraoperative neuromonitoring in corrective surgery for adolescent idiopathic scoliosis: evaluation of 354 consecutive cases","volume":"44","author":"Kundnani","year":"2010","journal-title":"Indian J Orthop"},{"key":"R36-20250621","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/WNP.0b013e31824f854b","article-title":"NIOM for spinal deformity surgery: there\u2019s more than one way to skin a cat","volume":"29","author":"Emerson","year":"2012","journal-title":"J Clin Neurophysiol"},{"key":"R37-20250621","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.2106\/00004623-200406000-00018","article-title":"Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery","volume":"86","author":"Hilibrand","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R38-20250621","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1097\/BSD.0000000000000558","article-title":"Diagnostic utility of intraoperative neurophysiological monitoring for intramedullary spinal cord tumors: systematic review and meta-analysis","volume":"31","author":"Azad","year":"2018","journal-title":"Clin Spine Surg"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001190","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T22:04:24Z","timestamp":1750543464000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001190"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,8]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001190","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,8]]},"assertion":[{"value":"2020-08-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}