{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T11:47:24Z","timestamp":1792842444941,"version":"4.5.0"},"reference-count":38,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>This was a retrospective cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>This study evaluates the patient-reported Health Related Quality of Life outcomes and radiographic parameters of patients who underwent a single level transforaminal lumbar interbody fusion with either a polyetheretherketone (PEEK) or titanium interbody cage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>Spinal stenosis with instability is a common diagnosis that is often treated with interbody fusion, in particular transforaminal lumbar interbody fusion. Titanium and PEEK interbody cage properties have been extensively studied to understand their effect on fusion rates and subsidence.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A retrospective cohort study was conducted from a single, high volume, academic hospital. Health Related Quality of Life outcomes were obtained from Outcomes Based Electronic Research Database and electronic medical record chart review. Subsidence was defined as a loss of 2\u2009mm or more in the anterior or posterior disk height. Spinopelvic alignment parameters measured were sacral slope, pelvic tilt, pelvic incidence, lumbar lordosis, segmental lordosis, and pelvic incidence-lumbar lordosis mismatch. Fusion rates were assessed by the Brantigan-Steffee criteria.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The study included a total of 137 patients (108 PEEK, 29 titanium). Overall, no significant changes were noted between the 2 groups at 3 month or 1-year follow-up. Perioperatively, patients did report improvement in all outcome parameters within the PEEK and titanium groups. No significant difference was noted in subsidence rate between the 2 groups. Segmental lordosis significantly increased within the PEEK (+4.8 degrees;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001) and titanium (+4.6 degrees;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.003) cage groups, however no difference was noted between groups. No significant difference was noted in fusion between the PEEK and titanium cage cohorts (92.6% vs. 86.2%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.36).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Overall, while PEEK and titanium cages exhibit unique biomaterial properties, our study shows that there were no significant differences with respect to patient-reported outcomes or radiographic outcomes between the 2 groups at the 1-year follow-up time point.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level III.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001201","type":"journal-article","created":{"date-parts":[[2021,8,9]],"date-time":"2021-08-09T18:46:08Z","timestamp":1628534768000},"page":"E483-E493","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":13,"title":["PEEK Versus Titanium Static Interbody Cages"],"prefix":"10.1097","volume":"34","author":[{"given":"Jose A.","family":"Canseco","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian A.","family":"Karamian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parthik D.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Srikanth N.","family":"Divi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyler","family":"Timmons","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haydn","family":"Hallman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Nachwalter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph K.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark F.","family":"Kurd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. Greg","family":"Anderson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey A.","family":"Rihn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan S.","family":"Hilibrand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher K.","family":"Kepler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander R.","family":"Vaccaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory D.","family":"Schroeder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,8,9]]},"reference":[{"key":"R1-20250621","first-page":"2","article-title":"Lumbar interbody fusion: Techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF, OLIF\/ATP, LLIF and ALIF","volume":"1","author":"Mobbs","year":"2015","journal-title":"J Spine Surg"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.spinee.2008.08.011","article-title":"Lumbar fusion outcomes stratified by specific diagnostic indication","volume":"9","author":"Glassman","year":"2009","journal-title":"Spine J"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"1842","DOI":"10.1007\/s00586-007-0393-z","article-title":"The outcome of spinal decompression surgery 5 years on","volume":"16","author":"Anjarwalla","year":"2007","journal-title":"Eur Spine J"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"379","DOI":"10.3171\/SPI-07\/10\/379","article-title":"Anterior lumbar interbody fusion in comparison with transforaminal lumbar interbody fusion: implications for the restoration of foraminal height, local disc angle, lumbar lordosis, and sagittal balance","volume":"7","author":"Hsieh","year":"2007","journal-title":"J Neurosurg Spine"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1097\/00007632-200103010-00023","article-title":"Comparison of posterior and transforaminal approaches to lumbar interbody fusion","volume":"26","author":"Humphreys","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R6-20250621","doi-asserted-by":"crossref","first-page":"E992","DOI":"10.1097\/01.brs.0000250177.84168.ba","article-title":"Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion\u2212A finite element study","volume":"31","author":"Vadapalli","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R7-20250621","doi-asserted-by":"crossref","first-page":"163","DOI":"10.21037\/jss.2017.05.01","article-title":"Elastic modulus in the selection of interbody implants","volume":"3","author":"Heary","year":"2017","journal-title":"J Spine Surg"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1007\/s00586-013-2772-y","article-title":"Comparison of titanium and polyetheretherketone (PEEK) cages in the surgical treatment of multilevel cervical spondylotic myelopathy: a prospective, randomized, control study with over 7-year follow-up","volume":"22","author":"Chen","year":"2013","journal-title":"Eur Spine J"},{"key":"R9-20250621","first-page":"201","article-title":"Clinical and radiological results after anterior cervical corpectomy with cage fusion\u2212A retrospective comparison of PEEK vs. titanium cages","volume":"155","author":"Schulz","year":"2017","journal-title":"Z Orthop Unfall"},{"key":"R10-20250621","first-page":"1412","article-title":"Radiological and clinical outcomes in patients undergoing anterior cervical discectomy and fusion: Comparing titanium and PEEK (polyetheretherketone) cages","volume":"34","author":"Junaid","year":"2013","journal-title":"Pak J Med Sci"},{"key":"R11-20250621","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s12306-018-0580-6","article-title":"PEEK versus metal cages in posterior lumbar interbody fusion: a clinical and radiological comparative study","volume":"103","author":"Cuzzocrea","year":"2019","journal-title":"Musculoskelet Surg"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"S53","DOI":"10.1016\/j.spinee.2014.12.035","article-title":"Radiological outcomes of PEEK vs titanium transforaminal lumbar interbody cages","volume":"15","author":"Lingutla","year":"2015","journal-title":"Spine J"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"471","DOI":"10.3171\/2012.1.SPINE11842","article-title":"Minimum clinically important difference in pain, disability, and quality of life after neural decompression and fusion for same-level recurrent lumbar stenosis: understanding clinical versus statistical significance","volume":"16","author":"Parker","year":"2012","journal-title":"J Neurosurg Spine"},{"key":"R14-20250621","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/s00586-010-1624-2","article-title":"Responsiveness of the Chinese version of the Oswestry disability index in patients with chronic low back pain","volume":"20","author":"Ma","year":"2011","journal-title":"Eur Spine J"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1016\/j.spinee.2019.07.014","article-title":"Fusion technique does not affect short-term patient reported outcomes for lumbar degenerative disease","volume":"19","author":"Divi","year":"2019","journal-title":"Spine J"},{"key":"R16-20250621","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s00586-004-0817-y","article-title":"Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages","volume":"15","author":"Choi","year":"2006","journal-title":"Eur Spine J"},{"key":"R17-20250621","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/BSD.0b013e318237b9b1","article-title":"Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion","volume":"26","author":"Kim","year":"2013","journal-title":"J Spinal Disord Tech"},{"key":"R18-20250621","doi-asserted-by":"crossref","first-page":"2106","DOI":"10.1097\/00007632-199310001-00030","article-title":"A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients","volume":"18","author":"Brantigan","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20250621","first-page":"e7070","article-title":"Two-year clinical and radiographic results with a multidimensional, expandable interbody implant in minimally invasive lumbar spine surgery","volume":"12","author":"Kucharzyk","year":"2020","journal-title":"Cureus"},{"key":"R20-20250621","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1007\/s00586-012-2619-y","article-title":"The clinical and radiological outcomes of multilevel minimally invasive transforaminal lumbar interbody fusion","volume":"22","author":"Min","year":"2013","journal-title":"Eur Spine J"},{"key":"R21-20250621","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1111\/os.12402","article-title":"Prospective study of long-term effect between multifidus muscle bundle and conventional open approach in one-level posterior lumbar interbody fusion","volume":"10","author":"Zhu","year":"2018","journal-title":"Orthop Surg"},{"key":"R22-20250621","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.jocn.2017.06.062","article-title":"Titanium vs. polyetheretherketone (PEEK) interbody fusion: Meta-analysis and review of the literature","volume":"44","author":"Seaman","year":"2017","journal-title":"J Clin Neurosci"},{"key":"R23-20250621","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1186\/s12891-016-1234-1","article-title":"Is PEEK cage better than titanium cage in anterior cervical discectomy and fusion surgery? A meta-analysis","volume":"17","author":"Li","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"key":"R24-20250621","doi-asserted-by":"crossref","first-page":"2150","DOI":"10.1007\/s00586-014-3466-9","article-title":"Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation","volume":"23","author":"Nemoto","year":"2014","journal-title":"Eur Spine J"},{"key":"R25-20250621","doi-asserted-by":"crossref","first-page":"248","DOI":"10.31616\/asj.2018.0169","article-title":"Early fusion status after posterior lumbar interbody fusion with cortical bone trajectory screw fixation: a comparison of titanium-coated polyetheretherketone cages and carbon polyetheretherketone cages","volume":"13","author":"Sakaura","year":"2019","journal-title":"Asian Spine J"},{"key":"R26-20250621","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.jos.2019.07.004","article-title":"Comparison in the Same Intervertebral Space Between Titanium-Coated and Uncoated PEEK Cages in Lumbar Interbody Fusion Surgery","volume":"25","author":"Kashii","year":"2020","journal-title":"J Orthop Sci"},{"key":"R27-20250621","doi-asserted-by":"crossref","first-page":"125","DOI":"10.14245\/ns.2040058.029","article-title":"Polyetheretherketone versus titanium cages for posterior lumbar interbody fusion: meta-analysis and review of the literature","volume":"17","author":"Massaad","year":"2020","journal-title":"Neurospine"},{"key":"R28-20250621","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.jocn.2017.06.039","article-title":"Does restoration of focal lumbar lordosis for single level degenerative spondylolisthesis result in better patient-reported clinical outcomes? A systematic literature review","volume":"44","author":"Rhee","year":"2017","journal-title":"J Clin Neurosci"},{"key":"R29-20250621","doi-asserted-by":"crossref","first-page":"e1374","DOI":"10.1016\/j.wneu.2019.03.106","article-title":"Comparison of segmental lordosis and global spinopelvic alignment after single-level lateral lumbar interbody fusion or transforaminal lumbar interbody fusion","volume":"126","author":"Saadeh","year":"2019","journal-title":"World Neurosurg"},{"key":"R30-20250621","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1007\/s00264-018-4222-2","article-title":"Sagittal alignment assessment after short-segment lumbar fusion for degenerative disc disease","volume":"43","author":"Vazifehdan","year":"2019","journal-title":"Int Orthop"},{"key":"R31-20250621","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.spinee.2015.09.038","article-title":"Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?","volume":"16","author":"Kienle","year":"2016","journal-title":"Spine J"},{"key":"R32-20250621","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1016\/j.spinee.2018.02.018","article-title":"Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model","volume":"18","author":"McGilvray","year":"2018","journal-title":"Spine J"},{"key":"R33-20250621","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1177\/0954411916667761","article-title":"Applications of 3D printing in the management of severe spinal conditions","volume":"231","author":"Provaggi","year":"2017","journal-title":"Proc Inst Mech Eng H"},{"key":"R36-20250621","doi-asserted-by":"crossref","first-page":"757","DOI":"10.21037\/jss.2018.12.01","article-title":"3-dimensional printing for anterior cervical surgery: a review","volume":"4","author":"Choy","year":"2018","journal-title":"J Spine Surg"},{"key":"R37-20250621","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1097\/BRS.0000000000003543","article-title":"Patient reported outcomes in patients who stop following up: are they doing better or worse than the patients that come back?","volume":"45","author":"Chen","year":"2020","journal-title":"Spine"},{"key":"R38-20250621","doi-asserted-by":"crossref","first-page":"E683","DOI":"10.1097\/BSD.0000000000000315","article-title":"The correlation between cage subsidence, bone mineral density, and clinical results in posterior lumbar interbody fusion","volume":"30","author":"Oh","year":"2017","journal-title":"Clin Spine Surg"},{"key":"R39-20250621","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s00586-015-4353-8","article-title":"Radiological and clinical outcomes of novel Ti\/PEEK combined spinal fusion cages: a systematic review and preclinical evaluation","volume":"26","author":"Assem","year":"2017","journal-title":"Eur Spine J"},{"key":"R40-20250621","doi-asserted-by":"crossref","first-page":"e1309","DOI":"10.1016\/j.wneu.2019.03.084","article-title":"Application of new allogeneic lumbar fusion cage (biocage) in single-segment lumbar degenerative disease: a prospective controlled study with follow-up for \u22652 years","volume":"126","author":"Wu-Jie","year":"2019","journal-title":"World Neurosurg"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001201","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T19:01:04Z","timestamp":1750532464000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001201"}},"subtitle":["A Comparison of 1-Year Clinical and Radiographic Outcomes for 1-Level TLIFs"],"short-title":[],"issued":{"date-parts":[[2021,8,9]]},"references-count":38,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001201","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8,9]]},"assertion":[{"value":"2020-07-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}