{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T16:22:20Z","timestamp":1780676540577,"version":"3.54.1"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The aim was to determine whether applying Arbeitsgemeinschaft f\u00fcr Osteosynthesefragen (AO) principles for external fixation of long bone fracture to patients with a 3-column osteotomy (3CO) would be associated with reduced rod fracture (RF) rates.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>AO dictate principles to follow when fixating long bone fractures: (1) decrease bone-rod distance; (2) increase the number of connecting rods; (3) increase the diameter of rods; (4) increase the working length of screws; (5) use multiaxial fixation. We hypothesized that applying these principles to patients undergoing a 3CO reduces the rate of RF.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Patients were categorized as having RF versus no rod fracture (non-RF). Details on location and type of instrumentation were collected. Dedicated software was used to calculate the distance between osteotomy site and adjacent pedicle screws, angle between screws and the distance between the osteotomy site and rod. Classic sagittal spinopelvic parameters were evaluated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The study included 170 patients (34=RF, 136=non-RF). There was no difference in age (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.224), sagittal vertical axis correction (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.287), or lumbar lordosis correction (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.36). There was no difference in number of screws cephalad (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.62) or caudal (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.31) to 3CO site. There was a lower rate of RF for patients with &gt;2 rods versus 2 rods (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.001). <jats:italic toggle=\"yes\">P<\/jats:italic>atients with multiplanar rod fixation had a lower rod fracture rate (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.01). For patients with only 2 rods (N=68), the non-RF cohort had adjacent screws that trended to have less angulation to each other (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.06) and adjacent screws that had a larger working length (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.03).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>A portion of AO principles can be applied to 3CO to reduce RF rates. Placing more rods around a 3CO site, placing rods in multiple planes, and placing adjacent screws with a larger working length around the 3CO site is associated with lower RF rates.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001289","type":"journal-article","created":{"date-parts":[[2021,12,30]],"date-time":"2021-12-30T12:30:17Z","timestamp":1640867417000},"page":"E429-E437","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Are the Arbeitsgemeinschaft F\u00fcr Osteosynthesefragen (AO) Principles for Long Bone Fractures Applicable to 3-Column Osteotomy to Reduce Rod Fracture Rates?"],"prefix":"10.1097","volume":"35","author":[{"given":"Sohrab","family":"Virk","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, North well Health, Great Neck"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renaud","family":"Lafage","sequence":"additional","affiliation":[{"name":"Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shay","family":"Bess","sequence":"additional","affiliation":[{"name":"Rocky Mountain Scoliosis and Spine Center, Denver, CO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Shaffrey","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Duke University, Durham, NC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han J.","family":"Kim","sequence":"additional","affiliation":[{"name":"Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Ames","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of California, San Francisco, San Francisco, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doug","family":"Burton","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Kansas Medical Center, Kansas City, KS"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Munish","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Washington University School of Medicine, St. Louis, MO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin S.","family":"Smith","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Virginia Medical Center, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Eastlack","sequence":"additional","affiliation":[{"name":"San Diego Spine Foundation, La Jolla"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Klineberg","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of California, Davis, Sacramento"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory","family":"Mundis","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, San Diego Center for Spinal Disorders, La Jolla, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Schwab","sequence":"additional","affiliation":[{"name":"Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Virginie","family":"Lafage","sequence":"additional","affiliation":[{"name":"Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"the International Spine Study Group","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,12,29]]},"reference":[{"key":"R1-20250621","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.clinbiomech.2019.10.014","article-title":"Biomechanical analysis of sagittal correction parameters for surgical instrumentation with pedicle subtraction osteotomy in adult spinal deformity","volume":"71","author":"Benoit","year":"2020","journal-title":"Clin Biomech"},{"key":"R2-20250621","doi-asserted-by":"crossref","first-page":"2452","DOI":"10.1007\/s00586-015-4279-1","article-title":"Biomechanical analysis of Ponte and pedicle subtraction osteotomies for the surgical correction of kyphotic deformities","volume":"25","author":"Salvi","year":"2016","journal-title":"Eur Spine J"},{"key":"R3-20250621","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1007\/s00586-016-4859-8","article-title":"Instrumentation failure following pedicle subtraction osteotomy: the role of rod material, diameter, and multi-rod constructs","volume":"26","author":"Luca","year":"2017","journal-title":"Eur Spine J"},{"key":"R4-20250621","doi-asserted-by":"crossref","first-page":"207","DOI":"10.4103\/sni.sni_44_17","article-title":"Biomechanical study of rod stress after pedicle subtraction osteotomy versus anterior column reconstruction: a finite element study","volume":"8","author":"Januszewski","year":"2017","journal-title":"Surg Neurol Int"},{"key":"R5-20250621","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.medengphy.2016.02.002","article-title":"Finite element analysis of the lumbar destabilization following pedicle subtraction osteotomy","volume":"38","author":"Ottardi","year":"2016","journal-title":"Med Eng Phys"},{"key":"R6-20250621","doi-asserted-by":"crossref","first-page":"7541","DOI":"10.4081\/or.2018.7541","article-title":"Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model","volume":"10","author":"Shah","year":"2018","journal-title":"Orthop Rev (Pavia)"},{"key":"R7-20250621","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1227\/NEU.0b013e31827ba066","article-title":"Effect of severity of rod contour on posterior rod failure in the setting of lumbar pedicle subtraction osteotomy (PSO): a biomechanical study","volume":"72","author":"Tang","year":"2012","journal-title":"Neurosurgery"},{"key":"R8-20250621","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.spinee.2018.11.003","article-title":"Optimal satellite rod constructs to mitigate rod failure following pedicle subtraction osteotomy (PSO): a finite element study","volume":"19","author":"Seyed Vosoughi","year":"2019","journal-title":"Spine J"},{"key":"R9-20250621","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1227\/NEU.0b013e3182672aab","article-title":"Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity","volume":"71","author":"Smith","year":"2012","journal-title":"Neurosurgery"},{"key":"R10-20250621","doi-asserted-by":"crossref","first-page":"994","DOI":"10.3171\/2014.9.SPINE131176","article-title":"Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity","volume":"21","author":"Smith","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"R11-20250621","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1177\/2192568217699392","article-title":"Multi-rod constructs can prevent rod breakage and pseudarthrosis at the lumbosacral junction in adult spinal deformity","volume":"7","author":"Merrill","year":"2017","journal-title":"Glob Spine J"},{"key":"R12-20250621","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/00005131-199704000-00014","article-title":"A technique for intramedullary nailing of proximal third tibia fractures","volume":"11","author":"Buehler","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R13-20250621","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1007\/s00402-009-0954-1","article-title":"Double or triple interlocking when nailing proximal tibial fractures? A biomechanical investigation","volume":"129","author":"Hansen","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"key":"R14-20250621","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1002\/jor.1100020312","article-title":"A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur","volume":"2","author":"Tencer","year":"1984","journal-title":"J Orthop Res"},{"key":"R15-20250621","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.jos.2020.03.002","article-title":"Biomechanical evaluation of internal fixation for the treatment of comminuted subtrochanteric femur fractures","volume":"26","author":"Tazawa","year":"2020","journal-title":"J Orthop Sci"},{"key":"R18-20250621","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s13013-017-0127-x","article-title":"Analysis of instrumentation failures after three column osteotomies of the spine","volume":"12","author":"Kavadi","year":"2017","journal-title":"Scoliosis Spinal Disord"},{"key":"R19-20250621","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/s13013-015-0056-5","article-title":"Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a retrospective case-series","volume":"10","author":"Barton","year":"2015","journal-title":"Scoliosis"},{"issue":"suppl","key":"R20-20250621","first-page":"s0036","article-title":"Reducing rod breakage and pseudarthrosis in pedicle subtraction osteotomy: the importance of rod number and configuration in 264 patients with 2-year follow-up","volume":"6","author":"Gupta","year":"2016","journal-title":"Glob Spine J"},{"key":"R21-20250621","doi-asserted-by":"crossref","first-page":"1899","DOI":"10.1097\/BRS.0000000000000556","article-title":"Comparison of standard 2-rod constructs to multiple-rod constructs for fixation across 3-column spinal osteotomies","volume":"39","author":"Hyun","year":"2014","journal-title":"Spine"},{"key":"R22-20250621","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1093\/ons\/opx151","article-title":"A novel 4-rod technique offers potential to reduce rod breakage and pseudarthrosis in pedicle subtraction osteotomies for adult spinal deformity correction","volume":"14","author":"Gupta","year":"2017","journal-title":"Oper Neurosurg"},{"key":"R23-20250621","doi-asserted-by":"crossref","first-page":"S24","DOI":"10.1097\/BRS.0000000000001431","article-title":"Rod strain after pedicle subtraction osteotomy: a biomechanical study","volume":"41","author":"Gehrchen","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R24-20250621","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1016\/j.spinee.2015.03.004","article-title":"Outrigger rod technique for supplemental support of posterior spinal arthrodesis","volume":"15","author":"Palumbo","year":"2015","journal-title":"Spine J"},{"key":"R25-20250621","first-page":"2192568220902401","article-title":"Nitinol memory rods versus titanium rods: a biomechanical comparison of posterior spinal instrumentation in a synthetic corpectomy model","volume":"11","author":"Massey","year":"2020","journal-title":"Glob Spine J"},{"key":"R26-20250621","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1148\/radiographics.13.4.8356269","article-title":"Spinal fixation. Part 3. Complications of spinal instrumentation","volume":"13","author":"Slone","year":"1993","journal-title":"Radiographics"},{"key":"R27-20250621","doi-asserted-by":"crossref","first-page":"E388","DOI":"10.1097\/BRS.0000000000001282","article-title":"Use of supplemental short pre-contoured accessory rods and cobalt chrome alloy posterior rods reduces primary rod strain and range of motion across the pedicle subtraction osteotomy level: an in vitro biomechanical study","volume":"41","author":"Hallager","year":"2016","journal-title":"Spine"},{"key":"R28-20250621","doi-asserted-by":"crossref","first-page":"2357","DOI":"10.1007\/s00586-018-5623-z","article-title":"Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy","volume":"27","author":"La Barbera","year":"2018","journal-title":"Eur Spine J"},{"key":"R29-20250621","doi-asserted-by":"crossref","first-page":"S163","DOI":"10.1016\/j.spinee.2013.07.411","article-title":"Rod fractures in spinal deformity surgery: does cobalt chrome really fracture less often?","volume":"13","author":"Hellman","year":"2013","journal-title":"Spine J"},{"key":"R30-20250621","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.wneu.2017.04.031","article-title":"Comparative study between cobalt chrome and titanium alloy rods for multilevel spinal fusion: proximal junctional kyphosis more frequently occurred in patients having cobalt chrome rods","volume":"103","author":"Han","year":"2017","journal-title":"World Neurosurg"},{"key":"R31-20250621","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1055\/s-0032-1331460","article-title":"Construct rigidity after fatigue loading in pedicle subtraction osteotomy with or without adjacent interbody structural cages","volume":"2","author":"Deviren","year":"2012","journal-title":"Global Spine J"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001289","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T22:03:57Z","timestamp":1750543437000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001289"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,29]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001289","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2021,12,29]]},"assertion":[{"value":"2020-12-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-11-17","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}