{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T14:58:32Z","timestamp":1794581912352,"version":"4.9.1"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Systematic review and meta-analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>Robot-guided (RG) pedicle screw placement offers several advantages over fluoroscopy-guided (FG) surgery to patients undergoing spinal fusion. Radiation exposure and detrimental risks associated with RG surgery are poorly described in the literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>We perform a systematic review and meta-analysis of randomized controlled trials comparing RG to FG spinal fusion to assess radiation exposure to patients and clinicians.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>MEDLINE, Embase, Web of Science, and Cochrane Central were systematically queried. Inclusion was restricted to RCTs in adults. Version 2 of the Cochrane risk-of-bias tool for RCTs (RoB 2) was used to evaluate risk of bias and quality was appraised using the GRADE assessment tool. Continuous data were pooled across trials with inverse variance weighting to mean difference (MD) and dichotomous data were pooled with Mantel-Haenszel weighting to odds ratio (OR) with corresponding 95% CI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 1042 patients (RG: 651; FG: 391) from 8 RCTs were included. Radiation time was reduced in the RG group by 39.6% (MD: \u221225.65 seconds, 95% CI: \u221251.07 to \u22120.22) with an estimated anteroposterior and lateral dose-area product in the RG group measuring 123.85\u00b173.12 and 241.08\u00b1142.33\u00a0cGycm\n                      <jats:sup>2<\/jats:sup>\n                      , respectively. Estimated cancer risk and detrimental hereditary disorder risk were reduced by 40.2% in the RG group (3.60\u00d710\n                      <jats:sup>\u22125<\/jats:sup>\n                      \u00b12.12\u00d710\n                      <jats:sup>\u22125<\/jats:sup>\n                      and 1.31\u00d710\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u00b17.72\u00d710\n                      <jats:sup>\u22127<\/jats:sup>\n                      , respectively). Intraoperative bleeding volume was reduced in the RG group (MD: \u221261.52\u00a0mL, 95% CI: \u2212100.16 to \u221222.87,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.002,\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      =48%). However, surgical duration was significantly higher in the RG group (MD: 12.01\u00a0min, 95% CI: 1.63\u201322.39). Pedicle screw accuracy and length of hospital stay differences were not significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Radiation exposure to patients undergoing spinal fusion is lower in RG surgery compared with FG surgery. These findings can be supported with long-term studies that better characterize radiation dosages associated with these procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level I.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001820","type":"journal-article","created":{"date-parts":[[2025,4,24]],"date-time":"2025-04-24T08:00:41Z","timestamp":1745481641000},"page":"107-116","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Radiation Exposure and Dose Estimates of Robot-Guided Versus Fluoroscopy-Guided Spinal Fusion"],"prefix":"10.1097","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1999-2017","authenticated-orcid":false,"given":"Jordan J.","family":"Levett","sequence":"first","affiliation":[{"name":"Faculty of Medicine, University of Montreal, Montreal, Quebec"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulrhman","family":"Alnasser","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, McGill University, Montreal, Quebec"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Uri","family":"Barak","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, McGill University, Montreal, Quebec"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lior M.","family":"Elkaim","sequence":"additional","affiliation":[{"name":"Department of Neurology and Neurosurgery, McGill University, Montreal, Quebec"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thien Sa","family":"Hoang","sequence":"additional","affiliation":[{"name":"Universit\u00e9 de Montr\u00e9al Biblioth\u00e8ques, University of Montreal, Montreal, Quebec\ufeff"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naif M.","family":"Alotaibi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, National Neuroscience Institute, King Fahad Medical City, Riyadh, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daipayan","family":"Guha","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, McMaster University, Hamilton, Ontario"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isaac L.","family":"Moss","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, University of Connecticut, Farmington, Connecticut"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander G.","family":"Weil","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, \ufeffCentre Hospitalier Universitaire Sainte-Justine, Montreal, Quebec"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael H.","family":"Weber","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, University of Connecticut, Farmington, Connecticut"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,24]]},"reference":[{"key":"R1-20260326","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/BF01834068","article-title":"Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients","volume":"6","author":"Laine","year":"1997","journal-title":"Eur Spine J"},{"issue":"suppl","key":"R2-20260326","doi-asserted-by":"crossref","first-page":"S144","DOI":"10.1097\/01.brs.0000236893.65878.39","article-title":"Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65","volume":"31","author":"DeWald","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R3-20260326","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s00701-005-0669-1","article-title":"Vascular injury and complication in neurosurgical spine surgery","volume":"148","author":"Inamasu","year":"2006","journal-title":"Acta Neurochir (Wien)"},{"key":"R4-20260326","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis","year":"2012","journal-title":"Eur Spine J"},{"key":"R5-20260326","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1097\/BRS.0000000000004048","article-title":"Complications and revision rates in minimally invasive robotic-guided versus fluoroscopic-guided spinal fusions","volume":"46","author":"Good","year":"2021","journal-title":"Spine (Phila Pa 1976)"},{"key":"R6-20260326","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1016\/j.wneu.2014.07.041","article-title":"Radiation safety and spine surgery: systematic review of exposure limits and methods to minimize radiation exposure","volume":"82","author":"Srinivasan","year":"2014","journal-title":"World Neurosurg"},{"key":"R7-20260326","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1097\/BRS.0000000000004685","article-title":"Projected lifetime cancer risk associated with intraoperative computed tomography for lumbar spine surgery","volume":"48","author":"Crawford","year":"2023","journal-title":"Spine (Phila Pa 1976)"},{"key":"R8-20260326","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.1007\/s11999-014-3503-3","article-title":"Does less invasive spine surgery result in increased radiation exposure? A systematic review","volume":"472","author":"Yu","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"R9-20260326","doi-asserted-by":"crossref","first-page":"e474","DOI":"10.1016\/j.wneu.2018.11.190","article-title":"Comparing next-generation robotic technology with 3-dimensional computed tomography navigation technology for the insertion of posterior pedicle screws","volume":"123","author":"Khan","year":"2019","journal-title":"World Neurosurg"},{"key":"R10-20260326","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.spinee.2020.09.007","article-title":"Safety and accuracy of robot-assisted placement of pedicle screws compared to conventional free-hand technique: a systematic review and meta-analysis","volume":"21","author":"Fatima","year":"2021","journal-title":"Spine J"},{"key":"R11-20260326","doi-asserted-by":"crossref","first-page":"e13964","DOI":"10.1111\/ijcp.13964","article-title":"Robot-assisted technique vs conventional freehand technique in spine surgery: a meta-analysis","volume":"75","author":"Fu","year":"2021","journal-title":"Int J Clin Pract"},{"key":"R12-20260326","doi-asserted-by":"crossref","first-page":"824","DOI":"10.21037\/atm-20-1106","article-title":"Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials","volume":"8","author":"Peng","year":"2020","journal-title":"Ann Transl Med"},{"key":"R13-20260326","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/s10195-022-00669-0","article-title":"Efficacy and safety of robotic spine surgery: systematic review and meta-analysis","volume":"23","author":"Luengo-Matos","year":"2022","journal-title":"J Orthop Traumatol"},{"key":"R14-20260326","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1186\/s13643-021-01626-4","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"10","author":"Page","year":"2021","journal-title":"Syst Rev"},{"key":"R16-20260326","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.jclinepi.2010.04.026","article-title":"GRADE guidelines: 1. Introduction\u2014GRADE evidence profiles and summary of findings tables","volume":"64","author":"Guyatt","year":"2011","journal-title":"J Clin Epidemiol"},{"key":"R17-20260326","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1097\/BSD.0000000000000351","article-title":"How high are radiation-related risks in minimally invasive transforaminal lumbar interbody fusion compared with traditional open surgery?","volume":"29","author":"Kim","year":"2016","journal-title":"Clin Spine Surg"},{"key":"R18-20260326","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1007\/s00586-005-0952-0","article-title":"Fluoroscopic radiation exposure of the kyphoplasty patient","volume":"15","author":"Boszczyk","year":"2006","journal-title":"Eur Spine J"},{"key":"R19-20260326","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1148\/radiol.2323031412","article-title":"Patient exposure and associated radiation risks from fluoroscopically guided vertebroplasty or kyphoplasty","volume":"232","author":"Perisinakis","year":"2004","journal-title":"Radiology"},{"key":"R20-20260326","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1056\/NEJMoa0901249","article-title":"Exposure to low-dose ionizing radiation from medical imaging procedures","volume":"361","author":"Fazel","year":"2009","journal-title":"N Engl J Med"},{"key":"R21-20260326","doi-asserted-by":"crossref","first-page":"2117","DOI":"10.1088\/0031-9155\/37\/11\/008","article-title":"Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product","volume":"37","author":"Heron","year":"1992","journal-title":"Phys Med Biol"},{"key":"R23-20260326","doi-asserted-by":"crossref","first-page":"e1057","DOI":"10.1016\/j.wneu.2019.01.243","article-title":"Effect of robot-assisted surgery on lumbar pedicle screw internal fixation in patients with osteoporosis","volume":"125","author":"Feng","year":"2019","journal-title":"World Neurosurg"},{"key":"R24-20260326","doi-asserted-by":"crossref","first-page":"e1779","DOI":"10.1002\/rcs.1779","article-title":"A prospective, randomized, controlled trial of robot-assisted vs freehand pedicle screw fixation in spine surgery","volume":"13","author":"Kim","year":"2017","journal-title":"Int J Med Robot"},{"issue":"suppl 1","key":"R25-20260326","doi-asserted-by":"crossref","first-page":"A12","DOI":"10.1227\/NEU.0b013e318270d02c","article-title":"Spinal robotics","volume":"72","author":"Roser","year":"2013","journal-title":"Neurosurgery"},{"key":"R26-20260326","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.jot.2019.09.002","article-title":"A preliminary study of a novel robotic system for pedicle screw fixation: a randomised controlled trial","volume":"20","author":"Li","year":"2020","journal-title":"J Orthop Translat"},{"key":"R27-20260326","doi-asserted-by":"crossref","first-page":"615","DOI":"10.3171\/2018.10.SPINE18487","article-title":"Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial","volume":"30","author":"Han","year":"2019","journal-title":"J Neurosurg Spine"},{"key":"R28-20260326","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/BRS.0000000000001778","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions","volume":"42","author":"Hyun","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"R29-20260326","doi-asserted-by":"crossref","first-page":"E496","DOI":"10.1097\/BRS.0b013e31824b7767","article-title":"Accuracy of robot-assisted placement of lumbar and sacral pedicle screws","volume":"37","author":"Ringel","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R30-20260326","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1002\/jrsm.1411","article-title":"Risk-of-bias VISualization (robvis): an R package and Shiny web app for visualizing risk-of-bias assessments","volume":"12","author":"McGuinness","year":"2021","journal-title":"Res Synth Methods"},{"key":"R31-20260326","first-page":"100199","article-title":"Comparing radiation dose of image-guided techniques in lumbar fusion surgery with pedicle screw insertion; a systematic review","volume":"13","author":"Caelers","year":"2023","journal-title":"N Am Spine Soc J"},{"key":"R32-20260326","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1007\/s00586-017-5333-y","article-title":"Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trials","volume":"27","author":"Gao","year":"2018","journal-title":"Eur Spine J"},{"key":"R33-20260326","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.arth.2018.11.023","article-title":"Serum metal ion levels in cementless metal-on-metal total hip arthroplasty: long-term follow-up trends","volume":"34","author":"Kim","year":"2019","journal-title":"J Arthroplasty"},{"key":"R34-20260326","doi-asserted-by":"crossref","first-page":"e69","DOI":"10.2106\/JBJS.J.01328","article-title":"Radiation exposure issues in orthopaedics","volume":"93","author":"Giordano","year":"2011","journal-title":"J Bone Joint Surg"},{"key":"R35-20260326","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1007\/s00586-018-5653-6","article-title":"Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose","volume":"27","author":"Harrison Farber","year":"2018","journal-title":"Eur Spine J"},{"key":"R36-20260326","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1111\/j.1537-2995.2009.02518.x","article-title":"Activity-based costs of blood transfusions in surgical patients at four hospitals","volume":"50","author":"Shander","year":"2010","journal-title":"Transfusion (Paris)"},{"key":"R37-20260326","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1007\/s00586-006-0066-3","article-title":"Cost and utilization of blood transfusion associated with spinal surgeries in the United States","volume":"16","author":"Blanchette","year":"2007","journal-title":"Eur Spine J"},{"key":"R38-20260326","doi-asserted-by":"crossref","first-page":"35","DOI":"10.5435\/JAAOS-D-16-00184","article-title":"Blood-loss management in spine surgery","volume":"26","author":"Bible","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"key":"R39-20260326","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1007\/s00701-015-2535-0","article-title":"Unskilled unawareness and the learning curve in robotic spine surgery","volume":"157","author":"Schatlo","year":"2015","journal-title":"Acta Neurochir (Wien)"},{"key":"R40-20260326","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","article-title":"Accuracy of current techniques for placement of pedicle screws in the spine: a comprehensive systematic review and meta-analysis of 51,161 Screws","volume":"126","author":"Perdomo-Pantoja","year":"2019","journal-title":"World Neurosurg"},{"key":"R41-20260326","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1177\/2192568220927713","article-title":"A systematic review and meta-analysis of randomized controlled trials comparing the accuracy and clinical outcome of pedicle screw placement using robot-assisted technology and conventional freehand technique","volume":"11","author":"Tarawneh","year":"2021","journal-title":"Global Spine J"},{"key":"R42-20260326","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1002\/sim.698","article-title":"A comparison of methods to detect publication bias in meta-analysis","volume":"20","author":"Macaskill","year":"2001","journal-title":"Stat Med"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001820","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T15:00:53Z","timestamp":1774537253000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001820"}},"subtitle":["A Meta-Analysis of Randomized Controlled Trials"],"short-title":[],"issued":{"date-parts":[[2025,4,24]]},"references-count":40,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001820","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,24]]},"assertion":[{"value":"2024-06-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}