{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T16:38:28Z","timestamp":1794328708013,"version":"4.9.0"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Prospective study<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>This study aims to describe a workflow and custom instruments for robotic-assisted cervical pedicle screw placement using the MazorX Stealth Edition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>Posterior cervical spinal instrumentation using pedicle screws offers biomechanical advantages but carries risks of injury to the vertebral artery and nerve roots. Fluoroscopic and navigation aids exist, yet robotic assistance for cervical pedicle screw placement lacks a defined workflow. While previous generations of spine robots have been used in placing pedicle screws, there are no papers in literature that described the use of third-generation spine robots in placing them.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Twenty-two patients undergoing cervical pedicle screw placement with custom instruments and robotic assistance were included. Screw trajectories were planned and executed by the robotic arm, with postoperative O-arm scans assessing accuracy. Clinical and radiologic outcomes at 3-month follow-up were measured.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 206 screws were placed with a 98.1% accuracy rate. Four screws breached the pedicle without resulting in nerve root injury. Average surgical time was 190 minutes, with 6 minutes per screw insertion. Blood loss averaged 180\u00a0mL. NDI scores improved from 42.3 to 28.2. Complications included superficial wound infections in 2 patients, deep wound infection in 1, and 1 nondominant vertebral artery injury.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Robotic-assisted cervical pedicle screw placement demonstrates high accuracy and significant clinical improvements, validating the workflow and custom instruments developed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001841","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T08:00:45Z","timestamp":1749196845000},"page":"E183-E187","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Robotic-assisted Cervical Pedicle Screw Fixation With Custom Instruments"],"prefix":"10.1097","volume":"39","author":[{"given":"Madhava","family":"Pai","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal"},{"name":"Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vidyadhara","family":"Srinivasa","sequence":"additional","affiliation":[{"name":"Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Balamurugan","family":"Thirugnanam","sequence":"additional","affiliation":[{"name":"Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhishek","family":"Soni","sequence":"additional","affiliation":[{"name":"Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anjana","family":"Kashyap","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alia","family":"Vidyadhara","sequence":"additional","affiliation":[{"name":"Department of Spine Anesthesia, Manipal Hospital, Bangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sharath K.","family":"Rao","sequence":"additional","affiliation":[{"name":"Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"key":"R1-20260326","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","article-title":"Cervical pedicle screws versus lateral mass screws: anatomic feasibility and biomechanical comparison","volume":"22","author":"Jones","journal-title":"Spine"},{"key":"R2-20260326","first-page":"415","article-title":"Cervical pedicle screw placement using the \u201ckey slot technique\u201d: the feasibility and learning curve","volume":"25","author":"Lee","year":"2012","journal-title":"Clin Spine Surg"},{"key":"R3-20260326","first-page":"297","article-title":"Posterior cervical lateral mass screw fixation: analysis of 1026 consecutive screws in 143 patients","volume":"18","author":"Sekhon","year":"2005","journal-title":"Clin Spine Surg"},{"key":"R4-20260326","doi-asserted-by":"crossref","first-page":"2136","DOI":"10.2106\/JBJS.L.01522","article-title":"Lateral mass screw fixation in the cervical spine: a systematic literature review","volume":"95","author":"Coe","year":"2013","journal-title":"JBJS"},{"key":"R5-20260326","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.1097\/BRS.0b013e31818043ce","article-title":"Indications for cervical pedicle screw instrumentation in nontraumatic lesions","volume":"33","author":"Hasegawa","year":"2008","journal-title":"Spine"},{"key":"R6-20260326","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1097\/01.brs.0000137287.67388.0b","article-title":"Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine","volume":"29","author":"Kothe","year":"2004","journal-title":"Spine"},{"key":"R7-20260326","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1097\/00007632-200004150-00011","article-title":"Complications of pedicle screw fixation in reconstructive surgery of the cervical spine","volume":"25","author":"Abumi","year":"2000","journal-title":"Spine"},{"key":"R8-20260326","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1007\/s00586-009-1032-7","article-title":"Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope","volume":"18","author":"Yukawa","year":"2009","journal-title":"Eur Spine J"},{"key":"R9-20260326","doi-asserted-by":"crossref","first-page":"E349","DOI":"10.1097\/BRS.0b013e318239cf1f","article-title":"Reconstruction of the subaxial cervical spine using pedicle screw instrumentation","volume":"37","author":"Abumi","year":"2012","journal-title":"Spine"},{"key":"R10-20260326","doi-asserted-by":"crossref","first-page":"472","DOI":"10.3171\/2011.6.SPINE10809","article-title":"Intraoperative, full-rotation, three-dimensional image (O-arm)\u2013based navigation system for cervical pedicle screw insertion","volume":"15","author":"Ishikawa","year":"2011","journal-title":"J Neurosurg Spine"},{"key":"R11-20260326","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/s00586-012-2499-1","article-title":"Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients","volume":"22","author":"Hu","year":"2013","journal-title":"Eur Spine J"},{"key":"R12-20260326","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1007\/s00586-013-2879-1","article-title":"Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review","volume":"23","author":"Marcus","year":"2014","journal-title":"Eur Spine J"},{"key":"R13-20260326","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine"},{"key":"R14-20260326","doi-asserted-by":"crossref","first-page":"238","DOI":"10.3171\/2011.11.SPINE11102","article-title":"Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients","volume":"16","author":"Nakashima","year":"2012","journal-title":"J Neurosurg Spine"},{"key":"R15-20260326","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.jocn.2011.05.041","article-title":"Neurovascular complications of cervical pedicle screw fixation","volume":"19","author":"Kotil","year":"2012","journal-title":"J Clin Neurosci"},{"key":"R16-20260326","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s00586-022-07110-4","article-title":"Robotic-guided placement of cervical pedicle screws: feasibility and accuracy","volume":"31","author":"Kisinde","year":"2022","journal-title":"Eur Spine J"},{"key":"R17-20260326","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1177\/21925682211068410","article-title":"Anatomical and technical considerations of robot-assisted cervical pedicle screw placement: a cadaveric study","volume":"13","author":"Mao","year":"2023","journal-title":"Glob Spine J"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001841","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T15:00:55Z","timestamp":1774537255000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001841"}},"subtitle":["An Analysis of 206 Screws in 22 Patients"],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001841","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,6]]},"assertion":[{"value":"2024-09-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}