{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T11:05:19Z","timestamp":1788951919892,"version":"build-2803163510"},"reference-count":38,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Biomechanical study on bone surrogates reconstructed from cadaveric vertebrae.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The goal of this study was to evaluate the influence of cage positioning on construct strength and to determine the relationship between the depth of the epiphyseal rim and subsidence load in anterior lumbar interbody fusion (ALIF).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>Cage subsidence is a significant complication affecting fusion success with an incidence range of 6%\u201323%. Cage subsidence can result in chronic pain due to altered spine alignment, loss of intervertebral height, and inflammatory response. Reoperation rates can range from 5% to 20%. Understanding the impact of cage positioning and endplate characteristics on subsidence is crucial for optimizing surgical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Sixteen cadaveric (L3\u2013L5) lumbar segments were utilized. Bone surrogates were prepared to represent the heterogeneous structure of lumbar vertebrae. Compression testing was performed using a cage, similar to the cages used in ALIF procedures, shaped indenter with 3 cage positioning configurations: maximized, partial, and null overlap with the epiphyseal rim. Construct stiffness and subsidence load were measured.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Cage positioning significantly influenced subsidence load (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01) and construct stiffness (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.02). More specifically, cages with maximized epiphyseal contact demonstrated significantly higher subsidence loads than the others (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.01). The thickness of the cortical bone was highly correlated with subsidence load when maximized epiphyseal rim contact was achieved (\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.83,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Placement of ALIF cages along the anterior epiphyseal rim increases construct strength. A correlation exists between the thickness of the epiphyseal rim and cage subsidence, suggesting potential preoperative estimation of subsidence load based on epiphyseal rim thickness.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001855","type":"journal-article","created":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T08:02:35Z","timestamp":1750233755000},"page":"298-303","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Anterior Lumbar Interbody Fusion Implant Positioning in Relation to the Epiphyseal Rim"],"prefix":"10.1097","volume":"39","author":[{"given":"Jay","family":"Manuel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-4302-9385","authenticated-orcid":false,"given":"Madeline","family":"Gautreaux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1799-8703","authenticated-orcid":false,"given":"Andrew S.","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Robinson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9363-0826","authenticated-orcid":false,"given":"Milan","family":"Mody","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caroline","family":"Hannigan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tunde","family":"Abubakar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0994-5724","authenticated-orcid":false,"given":"Giovanni F.","family":"Solitro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,6,18]]},"reference":[{"key":"R1-20260623","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1097\/BRS.0b013e3181a18263","article-title":"Degenerative lumbar disc and facet disease in older adults: prevalence and clinical correlates","volume":"34","author":"Hicks","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"R2-20260623","first-page":"2","article-title":"Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF, OLIF\/ATP, LLIF and ALIF","volume":"1","author":"Mobbs","year":"2015","journal-title":"J Spine Surg"},{"key":"R3-20260623","doi-asserted-by":"crossref","first-page":"E226","DOI":"10.1097\/BSD.0000000000000904","article-title":"Trends in anterior lumbar interbody fusion in the United States: a marketscan study from 2007 to 2014","volume":"33","author":"Varshneya","year":"2020","journal-title":"Clin Spine Surg"},{"key":"R4-20260623","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/s00586-022-07516-0","article-title":"OLIF versus ALIF: Which is the better surgical approach for degenerative lumbar disease? A systematic review","volume":"32","author":"Sun","year":"2023","journal-title":"Eur Spine J"},{"key":"R5-20260623","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1007\/s00701-010-0876-2","article-title":"Failed anterior lumbar interbody fusion due to incomplete foraminal decompression","volume":"153","author":"Choi","year":"2011","journal-title":"Acta Neurochir (Wien)"},{"key":"R6-20260623","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1111\/os.12259","article-title":"Evolution of design of interbody cages for anterior lumbar interbody fusion","volume":"8","author":"Phan","year":"2016","journal-title":"Orthop Surg"},{"key":"R7-20260623","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s00586-004-0817-y","article-title":"Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages","volume":"15","author":"Choi","year":"2006","journal-title":"Eur Spine J"},{"key":"R8-20260623","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4061\/2011\/176497","article-title":"Anterior lumbar interbody implants: importance of the interdevice distance","volume":"2011","author":"Subach","year":"2011","journal-title":"Adv Orthop"},{"key":"R9-20260623","doi-asserted-by":"crossref","first-page":"168","DOI":"10.21037\/jss.2017.05.03","article-title":"Subsidence following anterior lumbar interbody fusion (ALIF): a prospective study","volume":"3","author":"Phan","year":"2017","journal-title":"J Spine Surg"},{"key":"R10-20260623","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.14444\/8363","article-title":"Subsidence of spinal fusion cages: a systematic review","volume":"16","author":"Parisien","year":"2022","journal-title":"Int J Spine Surg"},{"key":"R11-20260623","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1115\/1.4042181","article-title":"The effects of bone microstructure on subsidence risk for ALIF, LLIF, PLIF, and TLIF spine cages","volume":"141","author":"Palepu","year":"2019","journal-title":"J Biomech Eng"},{"key":"R12-20260623","first-page":"1","article-title":"Risk factors for subsidence following anterior lumbar interbody fusion","volume":"0","author":"Zavras","year":"2022","journal-title":"Global Spine J"},{"key":"R13-20260623","doi-asserted-by":"crossref","first-page":"332","DOI":"10.3171\/2020.2.SPINE191418","article-title":"The impact of obesity on perioperative complications in patients undergoing anterior lumbar interbody fusion","volume":"33","author":"Safaee","year":"2020","journal-title":"J Neurosurg Spine"},{"key":"R14-20260623","doi-asserted-by":"crossref","first-page":"168","DOI":"10.21037\/jss.2017.05.03","article-title":"Subsidence following anterior lumbar interbody fusion (ALIF): a prospective study","volume":"3","author":"Rao","year":"2017","journal-title":"J Spine Surg"},{"key":"R15-20260623","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/BSD.0b013e31825bd26d","article-title":"Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion: a systematic review","volume":"27","author":"Karikari","year":"2014","journal-title":"J Spinal Disord Tech"},{"key":"R16-20260623","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1097\/BRS.0000000000003194","article-title":"Does lumbar interbody cage size influence subsidence? A biomechanical study","volume":"45","author":"Yuan","year":"2020","journal-title":"Spine (Phila Pa 1976)"},{"key":"R17-20260623","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/00007632-198703000-00012","article-title":"Analysis of the morphometric characteristics of the thoracic and lumbar pedicles","volume":"12","author":"Zindrick","year":"1987","journal-title":"Spine (Phila Pa 1976)"},{"key":"R18-20260623","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1097\/00007632-200104150-00012","article-title":"Mapping the structural properties of the lumbosacral vertebral endplates","volume":"26","author":"Grant","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20260623","doi-asserted-by":"crossref","first-page":"2316","DOI":"10.1007\/s00586-012-2415-8","article-title":"A morphological study of lumbar vertebral endplates: radiographic, visual and digital measurements","volume":"21","author":"Wang","year":"2012","journal-title":"Eur Spine J"},{"key":"R20-20260623","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/BRS.0b013e3181e9b19d","article-title":"The epiphyseal ring: a long forgotten anatomical structure with significant physiological function","volume":"36","author":"Dar","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R21-20260623","doi-asserted-by":"crossref","first-page":"jor.24323","DOI":"10.1002\/jor.24323","article-title":"Safe supra-acetabular pin insertion in relation to intraosseous depth","volume":"37","author":"Morandi","year":"2019","journal-title":"J Orthop Res"},{"key":"R22-20260623","doi-asserted-by":"crossref","first-page":"100105","DOI":"10.1016\/j.bea.2023.100105","article-title":"Benchtop impaction device replicates cadaveric loading conditions of the transforaminal lumbar interbody fusion (TLIF) procedure","volume":"6","author":"Graham","year":"2023","journal-title":"Biomed Eng Adv"},{"key":"R23-20260623","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.jmbbm.2019.06.013","article-title":"Experimental study on the loosening of pedicle screws implanted to synthetic bone vertebra models and under non-pull-out mechanical loads","volume":"98","author":"Nowak","year":"2019","journal-title":"J Mech Behav Biomed Mater"},{"key":"R24-20260623","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1111\/os.12872","article-title":"Influence of cage design on radiological and clinical outcomes in dorsal lumbar spinal fusions: a comparison of lordotic and non-lordotic cages","volume":"13","author":"Walter","year":"2021","journal-title":"Orthop Surg"},{"key":"R25-20260623","doi-asserted-by":"crossref","first-page":"105764","DOI":"10.1016\/j.clinbiomech.2022.105764","article-title":"Biomechanical comparison of subsidence performance among three modern porous lateral cage designs","volume":"99","author":"Yee-Yanagishita","year":"2022","journal-title":"Clin Biomech"},{"key":"R26-20260623","doi-asserted-by":"crossref","first-page":"111635","DOI":"10.1016\/j.jbiomech.2023.111635","article-title":"Resisting subsidence with a truss implant: application of the \u201cSnowshoe\u201d principle for interbody fusion devices","volume":"155","author":"Kiapour","year":"2023","journal-title":"J Biomech"},{"key":"R27-20260623","doi-asserted-by":"crossref","first-page":"86","DOI":"10.5435\/00124635-201202000-00004","article-title":"Biomechanical testing of fracture fixation constructs: variability, validity, and clinical applicability","volume":"20","author":"Gardner","year":"2012","journal-title":"J Am Acad Orthop Surg"},{"key":"R28-20260623","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1111\/os.12283","article-title":"Anterior lumbar interbody fusion integrated screw cages: intrinsic load generation, subsidence, and torsional stability","volume":"9","author":"Assem","year":"2017","journal-title":"Orthop Surg"},{"key":"R29-20260623","first-page":"1419","article-title":"An update in complication rates associated with anterior lumbar surgery: a systematic review and meta-analysis","volume":"0","author":"Issa","year":"2024","journal-title":"Glob Spine J"},{"key":"R30-20260623","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1186\/s12891-019-2630-0","article-title":"Cage positioning as a risk factor for posterior cage migration following transforaminal lumbar interbody fusion\u2014an analysis of 953 cases","volume":"20","author":"Hu","year":"2019","journal-title":"BMC Musculoskelet Disord"},{"key":"R31-20260623","doi-asserted-by":"crossref","first-page":"E1158","DOI":"10.1097\/BRS.0000000000002158","article-title":"Does spanning a lateral lumbar interbody cage across the vertebral ring apophysis increase loads required for failure and mitigate endplate violation","volume":"42","author":"Briski","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"R32-20260623","doi-asserted-by":"crossref","first-page":"2747","DOI":"10.1007\/s00586-017-5009-7","article-title":"Two-piece ALIF cage optimizes the bone\u2013implant interface in a 360\u00b0 setting","volume":"26","author":"Wilke","year":"2017","journal-title":"Eur Spine J"},{"key":"R33-20260623","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s13018-022-03480-z","article-title":"Computational comparison of anterior lumbar interbody fusion and oblique lumbar interbody fusion with various supplementary fixation systems: a finite element analysis","volume":"18","author":"Ouyang","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R34-20260623","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1097\/BSD.0b013e3182263d91","article-title":"Stand-alone anterior versus anteroposterior lumbar interbody single-level fusion after a mean follow-up of 41 months","volume":"25","author":"Strube","year":"2012","journal-title":"J Spinal Disord Tech"},{"key":"R35-20260623","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1080\/02688697.2018.1432750","article-title":"The safe use of long screws in L5\/S1 stand-alone anterior interbody fusion for olisthesis cases","volume":"32","author":"K\u00f6nig","year":"2018","journal-title":"Br J Neurosurg"},{"key":"R36-20260623","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1177\/21925682221134913","article-title":"Biomechanical comparison of subsidence between patient-specific and non-patient-specific lumbar interbody fusion cages","volume":"14","author":"Fernandes","year":"2024","journal-title":"Glob Spine J"},{"key":"R37-20260623","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.bone.2008.10.048","article-title":"Vertebral fractures usually affect the cranial endplate because it is thinner and supported by less-dense trabecular bone","volume":"44","author":"Zhao","year":"2009","journal-title":"Bone"},{"key":"R38-20260623","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/S0022-3913(99)70254-4","article-title":"Fabrication and use of a surgical template for placing implants to retain an auricular prosthesis","volume":"81","author":"Asher","year":"1999","journal-title":"J Prosthet Dent"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001855","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T19:01:51Z","timestamp":1782241311000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001855"}},"subtitle":["An Experimental Study on Bone Surrogates Reconstructed From Computer Tomography"],"short-title":[],"issued":{"date-parts":[[2025,6,18]]},"references-count":38,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001855","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,18]]},"assertion":[{"value":"2024-08-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}