{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T12:40:11Z","timestamp":1755866411010,"version":"3.44.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Study design:<\/jats:title>\n            <jats:p>Retrospective study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To compare reoperation rates between single-level standalone anterior cervical discectomy and fusion (ACDF) and ACDF with anterior plating.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>ACDF is a widely performed procedure for cervical degenerative disc disease and may utilize standalone cages or cages with anterior plating. Reoperation rate serves as a critical measure of long-term success and durability of each technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The PearlDiver national insurance claims database was used to identify patients who underwent single-level ACDF with a standalone cage or ACDF with a plate. 1:1 matched cohorts were created based on age, sex, Elixhauser Comorbidity Index score, and year of surgery. The primary outcome was the reoperation rate at 2 years postoperatively. Secondary analyses included reoperation rate at 1-year and 5-years, reoperation stratified by surgical approach, and rate of epidural or facet injections at 2-years after index surgery. Statistical analyses included \u03c7<jats:sup>2<\/jats:sup> tests and Kaplan-Meier analysis to compare reoperation rates.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Nine thousand three hundred twenty-six patients were included in each cohort after matching. The 2-year reoperation rate was 3.26% for ACDF with plate and 3.31% for standalone ACDF (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.837). No significant difference was found in reoperation rates at 1-year, 2-year, and 5-year. Kaplan-Meier analysis additionally demonstrated no significant difference in reoperation-free survival over time. Patients undergoing standalone ACDF had higher rates of posterior approach reoperations within 2 years (1.22% vs. 0.84%, <jats:italic toggle=\"yes\">P<\/jats:italic>=0.011). No significant differences were found in the rate of epidural or facet injections between groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Standalone and plated single-level ACDF provide comparable long-term outcomes in terms of reoperation rates. This study is the largest matched cohort to date of patients who underwent single-level ACDF with and without anterior plating.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Level III.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001917","type":"journal-article","created":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T12:01:07Z","timestamp":1755864067000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Reoperation Rate Following Single-Level Anterior Cervical Discectomy and Fusion With Standalone Cage Versus Anterior Plating in a Large Matched Cohort"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-6548-3354","authenticated-orcid":false,"given":"Adeesya","family":"Gausper","sequence":"first","affiliation":[{"name":"Department of Neurosurgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew M.","family":"Miller","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vivien","family":"Chan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suhas K.","family":"Etigunta","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andy M.","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Skaggs","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tiffany","family":"Perry","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Corey","family":"Walker","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Tuchman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,8,22]]},"reference":[{"key":"R1-20250822","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1097\/BRS.0000000000003613","article-title":"The outcomes of patients with neck pain following ACDF: a comparison of patients with radiculopathy, myelopathy, or mixed symptomatology","volume":"45","author":"Stull","year":"2020","journal-title":"Spine"},{"key":"R2-20250822","doi-asserted-by":"crossref","first-page":"2138","DOI":"10.1097\/01.brs.0000180479.63092.17","article-title":"Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5- to 11-year radiologic and clinical follow-up study","volume":"30","author":"Yue","year":"2005","journal-title":"Spine"},{"key":"R3-20250822","doi-asserted-by":"crossref","first-page":"E825","DOI":"10.1097\/BRS.0000000000001979","article-title":"Improvements in neck and arm pain following an anterior cervical discectomy and fusion","volume":"42","author":"Massel","year":"2017","journal-title":"Spine"},{"key":"R4-20250822","doi-asserted-by":"crossref","first-page":"E752","DOI":"10.1097\/BRS.0000000000002511","article-title":"Comparing health-related quality of life outcomes in patients undergoing either primary or revision anterior cervical discectomy and fusion","volume":"43","author":"Schroeder","year":"2018","journal-title":"Spine"},{"key":"R5-20250822","doi-asserted-by":"crossref","first-page":"E413","DOI":"10.1097\/BRS.0000000000002441","article-title":"Comparison of outcomes for anterior cervical discectomy and fusion with and without anterior plate fixation: a systematic review and meta-analysis","volume":"43","author":"Oliver","year":"2018","journal-title":"Spine"},{"key":"R6-20250822","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1007\/s00402-015-2212-z","article-title":"Zero-profile integrated plate and spacer device reduces rate of adjacent-level ossification development and dysphagia compared to ACDF with plating and cage system","volume":"135","author":"Yang","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"R7-20250822","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.surneu.2006.09.032","article-title":"Esophageal perforation from anterior cervical screw migration","volume":"68","author":"Sahjpaul","year":"2007","journal-title":"Surg Neurol"},{"key":"R8-20250822","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s00586-014-3628-9","article-title":"The application of zero-profile anchored spacer in anterior cervical discectomy and fusion","volume":"24","author":"Wang","year":"2015","journal-title":"Eur Spine J"},{"key":"R9-20250822","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.jocn.2016.01.042","article-title":"Subsidence after single-level anterior cervical fusion with a stand-alone cage","volume":"33","author":"Park","year":"2016","journal-title":"J Clin Neurosci"},{"key":"R10-20250822","doi-asserted-by":"crossref","first-page":"717","DOI":"10.3171\/2020.4.SPINE20357","article-title":"Pseudarthrosis in anterior cervical discectomy and fusion with a self-locking, stand-alone cage filled with hydroxyapatite: a retrospective study with clinical and radiological outcomes of 98 levels with a minimum 2-year follow-up","volume":"33","author":"Iunes","year":"2020","journal-title":"J Neurosurg Spine"},{"key":"R11-20250822","doi-asserted-by":"crossref","first-page":"2886","DOI":"10.1097\/BRS.0b013e3181b64f2c","article-title":"The efficacy of plate construct augmentation versus cage alone in anterior cervical fusion","volume":"34","author":"Song","year":"2009","journal-title":"Spine"},{"key":"R12-20250822","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1177\/2192568218774576","article-title":"Comparison of anterior cervical discectomy and fusion with a stand-alone interbody cage versus a conventional cage-plate technique: a systematic review and meta-analysis","volume":"9","author":"Cheung","year":"2019","journal-title":"Glob Spine J"},{"key":"R13-20250822","doi-asserted-by":"crossref","first-page":"558","DOI":"10.2106\/00004623-200503000-00012","article-title":"Development of adjacent-level ossification in patients with an anterior cervical plate","volume":"87","author":"Park","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"R14-20250822","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1177\/2192568220902749","article-title":"Adjacent-level ossification development in single-level standalone anterior cervical discectomy and fusion versus anterior cervical discectomy and fusion with plate","volume":"11","author":"Huang","year":"2021","journal-title":"Glob Spine J"},{"key":"R15-20250822","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.spinee.2004.06.022","article-title":"Surgical treatment of dysphagia after anterior cervical interbody fusion","volume":"5","author":"Fogel","year":"2005","journal-title":"Spine J"},{"key":"R16-20250822","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1016\/j.arth.2016.12.003","article-title":"Operative time affects short-term complications in total joint arthroplasty","volume":"32","author":"Duchman","year":"2017","journal-title":"J Arthroplasty"},{"key":"R17-20250822","doi-asserted-by":"crossref","first-page":"E1201","DOI":"10.1097\/BSD.0000000000000341","article-title":"Comparison of surgical outcomes, narcotics utilization, and costs after an anterior cervical discectomy and fusion: stand-alone cage versus anterior plating","volume":"30","author":"Tabaraee","year":"2017","journal-title":"Clin Spine Surg"},{"key":"R18-20250822","doi-asserted-by":"crossref","first-page":"315","DOI":"10.14245\/ns.2142214.107","article-title":"Effects of anterior plating on achieving clinically meaningful improvement following single-level anterior cervical discectomy and fusion","volume":"19","author":"Lynch","year":"2022","journal-title":"Neurospine"},{"key":"R19-20250822","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1111\/os.12339","article-title":"Biomechanical stability analysis of a stand-alone cage, static and rotational-dynamic plate in a two-level cervical fusion construct","volume":"9","author":"Tsitsopoulos","year":"2017","journal-title":"Orthop Surg"},{"key":"R20-20250822","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.spinee.2013.06.088","article-title":"Biomechanics of an integrated interbody device versus ACDF anterior locking plate in a single-level cervical spine fusion construct","volume":"14","author":"Stein","year":"2014","journal-title":"Spine J Off"},{"key":"R21-20250822","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BRS.0b013e31818ff9c4","article-title":"A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices","volume":"34","author":"Scholz","year":"2009","journal-title":"Spine"},{"key":"R22-20250822","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.wneu.2016.01.013","article-title":"The fate of adjacent segments after anterior cervical discectomy and fusion: the influence of an anterior plate system","volume":"89","author":"Ahn","year":"2016","journal-title":"World Neurosurg"},{"key":"R23-20250822","doi-asserted-by":"crossref","first-page":"39","DOI":"10.36076\/ppj\/2015.18.39","article-title":"Do cervical epidural injections provide long-term relief in neck and upper extremity pain? A systematic review","volume":"18","author":"Manchikanti","year":"2015","journal-title":"Pain Physician"},{"key":"R24-20250822","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.spinee.2005.07.003","article-title":"Treatment of anterior cervical pseudoarthrosis: posterior fusion versus anterior revision","volume":"6","author":"Carreon","year":"2006","journal-title":"Spine J Off"},{"key":"R25-20250822","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1177\/2192568219863808","article-title":"Outcomes of revision surgery for pseudarthrosis after anterior cervical fusion: case series and systematic review","volume":"10","author":"Steinhaus","year":"2020","journal-title":"Glob Spine J"},{"key":"R26-20250822","doi-asserted-by":"crossref","first-page":"2014","DOI":"10.1177\/21925682241279528","article-title":"Revision surgery after single level anterior cervical discectomy and fusion with plate vs stand-alone cage over 2 to 5 year follow-up","volume":"15","author":"Durand","year":"2025","journal-title":"Glob Spine J"},{"key":"R27-20250822","doi-asserted-by":"crossref","first-page":"e673","DOI":"10.1016\/j.wneu.2023.06.121","article-title":"Standalone versus anterior cervical plating for one-to-two level anterior cervical discectomy and fusion: a propensity score-matched comparative study","volume":"177","author":"Baig","year":"2023","journal-title":"World Neurosurg"},{"key":"R28-20250822","doi-asserted-by":"crossref","first-page":"896","DOI":"10.14245\/ns.2040216.108","article-title":"Synthetic cages associated with increased rates of revision surgery and higher costs compared to allograft in ACDF in the nonelderly patient","volume":"17","author":"Marrache","year":"2020","journal-title":"Neurospine"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001917","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T12:01:12Z","timestamp":1755864072000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001917"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,22]]},"references-count":28,"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001917","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,22]]},"assertion":[{"value":"2025-01-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}