{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:06:48Z","timestamp":1786118808145,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Retrospective cohort<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To evaluate surgical outcomes and opioid consumption among patients undergoing a C3-T1 posterior cervical decompression and fusion (PCDF) with lateral mass or pedicle screw fixation at C7.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Biomechanical work has suggested that junctional pedicle screws provide more robust fixation during cervicothoracic fixation at the expense of increased technical risk compared with lateral mass screws. However, minimal data exist directly comparing these 2 hardware options.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Adult patients who underwent primary C3-T1 PCDF (2017\u20132022) with C7 lateral mass versus pedicle screw fixation were compared. Patient demographics, surgical characteristics, and surgical outcomes were collected. Outpatient opioid utilization and morphine milligram equivalents (MMEs) from 1-year preoperatively to 1-year postoperatively were obtained from Pennsylvania Prescription Drug Monitoring Program. In-hospital MME data were also collected.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Thirty patients received lateral mass fixation, and 50 patients received pedicle screw fixation at C7. These groups were demographically similar, with similar average length of follow-up between the lateral mass (748\u00b1364\u00a0d) and pedicle screw (853\u00b1402\u00a0d,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.28) groups. Despite requiring a greater number of decompressed levels (4.17 vs. 3.74,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.002), cut-to-close time was shorter for the lateral mass group compared with the pedicle screw group (168\u00b137.6 vs. 191\u00b141.3\u00a0min,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.015). However, both groups were similar regarding surgical outcomes and preoperative and 1-year postoperative opioid consumption.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Despite a greater number of decompressed levels among the lateral mass group, these patients experienced a shorter average operative time during C3-T1 PCDF. However, short-term surgical outcomes and opioid consumption up to a year postoperatively were similar between groups. Thus, there does not appear to be short-term safety or pain drawbacks to C7 pedicle screws that would justify the decreased biomechanical advantages of lateral mass screws.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001935","type":"journal-article","created":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T15:00:06Z","timestamp":1767193206000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["The Impact of Lateral Mass Versus Pedicle Screws at C7 in C3-T1 Posterior Cervical Decompression and Fusion on Postsurgical Outcomes"],"prefix":"10.1097","author":[{"given":"Rajkishen","family":"Narayanan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory","family":"Toci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Dalton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Carter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William A.","family":"Green","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasmine","family":"Eichbaum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Mathew","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitchell","family":"Ng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lawrence","family":"Chiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Culkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Cha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xavier","family":"Becsey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abigail R.","family":"Tingstad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark F.","family":"Kurd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas D.","family":"Cha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian D.","family":"Kaye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose A.","family":"Canseco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan S.","family":"Hilibrand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander R.","family":"Vaccaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory D.","family":"Schroeder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher K.","family":"Kepler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,17]]},"reference":[{"key":"R1-20251231","first-page":"188","article-title":"Posterior fusion for the subaxial cervical spine: a review of the major techniques","volume":"16","author":"Mikhail","year":"2020","journal-title":"HSS J Musculoskelet J Hosp Spec Surg"},{"key":"R2-20251231","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1186\/1475-925X-13-115","article-title":"Four lateral mass screw fixation techniques in lower cervical spine following laminectomy: a finite element analysis study of stress distribution","volume":"13","author":"Song","year":"2014","journal-title":"Biomed Eng Online"},{"key":"R3-20251231","doi-asserted-by":"crossref","first-page":"726","DOI":"10.31616\/asj.2018.12.4.726","article-title":"Comparison of three different options for C7 posterior vertebral anchor in the Indian population\u2014lateral mass, pedicle, and lamina: a computed tomography-based morphometric analysis","volume":"12","author":"Viswanathan","year":"2018","journal-title":"Asian Spine J"},{"key":"R4-20251231","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","article-title":"Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison","volume":"22","author":"Jones","year":"1997","journal-title":"Spine"},{"key":"R5-20251231","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1186\/s12893-024-02358-7","article-title":"Free-hand technique of C7 pedicle screw insertion using a simply defined entry point without fluoroscopic guidance for cervical spondylotic myelopathy patients with C3 to C6 instrumented by lateral mass screws: a retrospective cohort study","volume":"24","author":"Jiang","year":"2024","journal-title":"BMC Surg"},{"key":"R6-20251231","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/00002517-200006000-00004","article-title":"Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance","volume":"13","author":"Kamimura","year":"2000","journal-title":"J Spinal Disord"},{"key":"R7-20251231","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1097\/00007632-199807150-00017","article-title":"Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology","volume":"23","author":"Albert","year":"1998","journal-title":"Spine"},{"key":"R8-20251231","doi-asserted-by":"crossref","first-page":"e68","DOI":"10.1016\/j.wneu.2019.05.201","article-title":"Safety and efficacy of skipping C7 instrumentation in posterior cervicothoracic fusion","volume":"130","author":"Tobin","year":"2019","journal-title":"World Neurosurg"},{"key":"R9-20251231","doi-asserted-by":"crossref","first-page":"E636","DOI":"10.1097\/01.brs.0000184750.80067.a1","article-title":"A comparison of pedicle and lateral mass screw construct stiffnesses at the cervicothoracic junction: a biomechanical study","volume":"30","author":"Rhee","year":"2005","journal-title":"Spine"},{"key":"R10-20251231","doi-asserted-by":"crossref","first-page":"E576","DOI":"10.1097\/BRS.0000000000003845","article-title":"Cervical alignment following posterior cervical fusion surgery: cervical pedicle screw versus lateral mass screw fixation","volume":"46","author":"Lee","year":"2021","journal-title":"Spine"},{"key":"R11-20251231","doi-asserted-by":"crossref","first-page":"2417","DOI":"10.1007\/s00586-017-5239-8","article-title":"Which salvage fixation technique is best for the failed initial screw fixation at the cervicothoracic junction? A biomechanical comparison study","volume":"26","author":"Hong","year":"2017","journal-title":"Eur Spine J"},{"key":"R12-20251231","doi-asserted-by":"crossref","first-page":"E16","DOI":"10.1097\/BRS.0b013e3181891772","article-title":"Biomechanical pullout strength and stability of the cervical artificial pedicle screw","volume":"34","author":"Barnes","year":"2009","journal-title":"Spine"},{"key":"R13-20251231","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1177\/2192568218759940","article-title":"Posterior subaxial cervical spine screw fixation: a review of techniques","volume":"8","author":"Joaquim","year":"2018","journal-title":"Glob Spine J"},{"key":"R14-20251231","doi-asserted-by":"crossref","first-page":"2136","DOI":"10.2106\/JBJS.L.01522","article-title":"Lateral mass screw fixation in the cervical spine: a systematic literature review","volume":"95","author":"Coe","year":"2013","journal-title":"JBJS"},{"key":"R15-20251231","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1097\/00007632-200007010-00009","article-title":"Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques","volume":"25","author":"Ludwig","year":"2000","journal-title":"Spine"},{"key":"R16-20251231","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s00586-006-0104-1","article-title":"Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data","volume":"16","author":"Reinhold","year":"2007","journal-title":"Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc"},{"key":"R17-20251231","doi-asserted-by":"crossref","first-page":"2800","DOI":"10.1097\/01.brs.0000192297.07709.5d","article-title":"The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae","volume":"30","author":"Neo","year":"2005","journal-title":"Spine"},{"key":"R18-20251231","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1097\/BSD.0000000000001411","article-title":"Crossing the cervicothoracic junction: a review of the current literature","volume":"35","author":"Vickery","year":"2022","journal-title":"Clin Spine Surg"},{"key":"R20-20251231","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s00586-004-0861-7","article-title":"Complications of transpedicular screw fixation in the cervical spine","volume":"15","author":"Kast","year":"2006","journal-title":"Eur Spine J"},{"key":"R21-20251231","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s00586-020-06359-x","article-title":"Acceptable errors with evaluation of 577 cervical pedicle screw placements","volume":"29","author":"Mahesh","year":"2020","journal-title":"Eur Spine J"},{"key":"R22-20251231","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.spinee.2006.03.019","article-title":"Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths","volume":"6","author":"Johnston","year":"2006","journal-title":"Spine J"},{"key":"R23-20251231","doi-asserted-by":"crossref","first-page":"2557","DOI":"10.1097\/00007632-199411001-00011","article-title":"Spinal disorders at the cervicothoracic junction","volume":"19","author":"An","year":"1994","journal-title":"Spine"},{"key":"R24-20251231","doi-asserted-by":"crossref","first-page":"278","DOI":"10.3171\/spi.2006.4.4.278","article-title":"Regional instability following cervicothoracic junction surgery","volume":"4","author":"Steinmetz","year":"2006","journal-title":"J Neurosurg Spine"},{"key":"R25-20251231","doi-asserted-by":"crossref","first-page":"1845","DOI":"10.1097\/BRS.0000000000001864","article-title":"Is it necessary to extend a multilevel posterior cervical decompression and fusion to the upper thoracic spine?","volume":"41","author":"Schroeder","year":"2016","journal-title":"Spine"},{"key":"R26-20251231","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1097\/01.bsd.0000156831.76055.f0","article-title":"Fractures and dislocations of the cervicothoracic junction","volume":"18","author":"Amin","year":"2005","journal-title":"J Spinal Disord Tech"},{"key":"R27-20251231","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.spinee.2013.09.013","article-title":"Cervicothoracic junction instability after cervical fusion","volume":"14","author":"Kurtom","year":"2014","journal-title":"Spine J"},{"key":"R28-20251231","doi-asserted-by":"crossref","first-page":"746","DOI":"10.3171\/2024.5.SPINE24207","article-title":"Comparison of robotic or computer-assisted navigation versus fluoroscopic freehand techniques in the accuracy of posterior cervical screw placement during cervical spine surgery: a meta-analysis","volume":"41","author":"Zhou","year":"2024","journal-title":"J Neurosurg Spine"},{"key":"R29-20251231","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1097\/BRS.0000000000001026","article-title":"Safety and efficacy of reconstruction of complex cervical spine pathology using pedicle screws inserted with stealth navigation and 3D image-guided (O-Arm) Technology","volume":"40","author":"Theologis","year":"2015","journal-title":"Spine"},{"key":"R30-20251231","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1097\/BRS.0000000000003827","article-title":"Use of intraoperative CT improves accuracy of spinal navigation during screw fixation in cervico-thoracic region","volume":"46","author":"Habib","year":"2021","journal-title":"Spine"},{"key":"R31-20251231","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s10143-016-0757-0","article-title":"Surgical safety of cervical pedicle screw placement with computer navigation system","volume":"40","author":"Shimokawa","year":"2017","journal-title":"Neurosurg Rev"},{"key":"R32-20251231","doi-asserted-by":"crossref","first-page":"2729","DOI":"10.1007\/s00586-018-5585-1","article-title":"Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation","volume":"27","author":"Chachan","year":"2018","journal-title":"Eur Spine J"},{"key":"R33-20251231","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1016\/j.spinee.2024.06.006","article-title":"Postoperative opioid consumption patterns diverge between propensity matched patients undergoing traumatic and elective cervical spine fusion","volume":"0","author":"Pohl","year":"2024","journal-title":"Spine J"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BSD.0000000000001935","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:01:54Z","timestamp":1786035714000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/BSD.0000000000001935"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,17]]},"references-count":32,"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001935","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,17]]},"assertion":[{"value":"2025-04-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}