{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T21:38:55Z","timestamp":1779399535114,"version":"3.53.1"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Retrospective case series.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>We aim to examine complications associated with the removal of spinal cord stimulator electrodes for the first time in a large cohort of patients that included both paddle and cylindrical electrodes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>Spinal cord stimulation (SCS) is a reversible treatment for many chronic pain syndromes that involves either open surgical placement of paddle electrodes or percutaneous placement of cylindrical leads. Potential complications associated with SCS removal are not well described in the literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We conducted a retrospective chart review of 139 patients who underwent removal of spinal cord stimulator electrodes at our institution between 2014 and 2022.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Nine out of 139 patients (6.5%) experienced postoperative complications, 7 of which occurred in patients who underwent more extensive concurrent spine surgeries. A complication occurred in only two of the 82 patients (2.4%) who had removal of their electrodes as a standalone procedure. In all but one patient (0.7%), the electrodes were able to be removed in their entirety.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Surgical removal of both cylindrical and paddle SCS electrodes as a standalone procedure is associated with a low rate of complications. Most observed complications occurred in patients who underwent concurrent spinal surgery and were likely attributable to those additional procedures rather than electrode removal itself.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000001990","type":"journal-article","created":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T22:00:24Z","timestamp":1770674424000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Complications Associated With Removal of Paddle and Cylindrical Spinal Cord Stimulator Electrodes"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3642-0846","authenticated-orcid":false,"given":"Andrew M.","family":"Miller","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Cedars-Sinai Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cedars-Sinai Medical Center"},{"name":"Charles R. Drew University of Medicine and Science College of Medicine, Los Angeles, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adeesya","family":"Gausper","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cedars-Sinai Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Corey T.","family":"Walker","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cedars-Sinai Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiffany G.","family":"Perry","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cedars-Sinai Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Tuchman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cedars-Sinai Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"R1-20260209","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.nec.2018.12.003","article-title":"Spinal cord stimulation","volume":"30","author":"Rock","year":"2019","journal-title":"Neurosurg Clin N Am"},{"key":"R2-20260209","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1111\/papr.12639","article-title":"Spinal cord stimulator explantation: motives for removal of surgically placed paddle systems","volume":"18","author":"Dupr\u00e9","year":"2018","journal-title":"Pain Pract"},{"key":"R3-20260209","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1016\/j.wneu.2013.06.012","article-title":"Is spinal cord stimulation safe? A review of its complications","volume":"82","author":"Bendersky","year":"2014","journal-title":"World Neurosurg"},{"key":"R4-20260209","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1111\/j.1533-2500.2010.00407.x","article-title":"Retrospective Review of 707 Cases of Spinal Cord Stimulation: Indications and Complications","volume":"11","author":"Mekhail","year":"2011","journal-title":"Pain Practice"},{"key":"R5-20260209","doi-asserted-by":"crossref","first-page":"191","DOI":"10.3171\/spi.2006.5.3.191","article-title":"Complications of spinal cord stimulation, suggestions to improve outcome, and financial impact","volume":"5","author":"Kumar","year":"2006","journal-title":"J Neurosurg Spine"},{"key":"R6-20260209","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1111\/ner.12643","article-title":"Rate of complications following spinal cord stimulation paddle electrode removal","volume":"21","author":"Maldonado-Naranjo","year":"2018","journal-title":"Neuromodulation"},{"key":"R7-20260209","doi-asserted-by":"crossref","first-page":"e348","DOI":"10.1227\/ons.0000000000000388","article-title":"Techniques for safe removal of spinal cord stimulation paddle leads","volume":"23","author":"Topp","year":"2022","journal-title":"Oper Neurosurg"},{"key":"R8-20260209","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/AAP.0000000000000026","article-title":"Epidural hematomas after removal of percutaneous spinal cord stimulator trial leads: two case reports","volume":"39","author":"Giberson","year":"2014","journal-title":"Reg Anesth Pain Med"},{"key":"R9-20260209","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/AAP.0000000000000029","article-title":"Spinal epidural hematoma after spinal cord stimulator trial lead placement in a patient taking aspirin","volume":"39","author":"Buvanendran","year":"2014","journal-title":"Reg Anesth Pain Med"},{"key":"R10-20260209","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1111\/ner.12065","article-title":"Outcomes of percutaneous and paddle lead implantation for spinal cord stimulation: a comparative analysis of complications, reoperation rates, and health-care costs","volume":"16","author":"Babu","year":"2013","journal-title":"Neuromodulation"},{"key":"R11-20260209","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/00006123-200002000-00025","article-title":"Laminectomy versus percutaneous electrode placement for spinal cord stimulation","volume":"46","author":"Villavicencio","year":"2000","journal-title":"Neurosurgery"},{"key":"R12-20260209","doi-asserted-by":"crossref","first-page":"100754","DOI":"10.1016\/j.semss.2019.100754","article-title":"Postoperative spine infections","volume":"31","author":"Attenello","year":"2019","journal-title":"Semin Spine Surg"},{"key":"R13-20260209","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1111\/ner.12799","article-title":"Removal of intrathecal catheters used in drug delivery systems","volume":"21","author":"Frizon","year":"2018","journal-title":"Neuromodulation"},{"key":"R14-20260209","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1111\/ner.12564","article-title":"The neurostimulation appropriateness consensus committee (NACC) safety guidelines for the reduction of severe neurological injury","volume":"20","author":"Deer","year":"2017","journal-title":"Neuromodulation"},{"key":"R15-20260209","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1016\/j.neurom.2024.01.004","article-title":"Spinal cord stimulation rial electrodes rapidly produce epidural scarring, impeding surgical paddle lead placement","volume":"27","author":"Treffy","year":"2024","journal-title":"Neuromodulation"},{"key":"R16-20260209","doi-asserted-by":"crossref","first-page":"657","DOI":"10.3171\/jns.1985.62.5.0657","article-title":"Vocal cord paralysis associated with anterior cervical fusion: considerations for prevention and treatment","volume":"62","author":"Bulger","year":"1985","journal-title":"J Neurosurgery"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001990","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T22:00:27Z","timestamp":1770674427000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000001990"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":16,"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000001990","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,13]]},"assertion":[{"value":"2025-03-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-02","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}